1675A BELDEN | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 3
Technical content
Product: 1675A Conformable Coax, 50 Ohm, RG-401, 14 AWG Solid SCCS, Copper-Tin Composite Shield, Unjacketed Product Description Conformable Coax, 50 Ohm, RG-401, 14 AWG Solid Silvered Copper Covered Steel Conductor, PTFE Insulation, Copper Tape + 100% Tin-Filled Composite Braid Shield, Unjacketed Technical Specifications Product Overview Suitable Applications: Microwave and other high frequency applications, Interconnect RF equipment, Radar equipment, Military communications Construction Details RG Type: 401 Conductor No. of Elements Size Stranding Nom. Diameter Material 1 14 AWG Solid 0.065 in SCCS - Silvered Copper Covered Steel Insulation Material Nom. Insulation Diameter Color Code PTFE - Polytetrafluoroethylene 0.21 in (5.3 mm) White Outer Shield Layer Outer Shield Type Material Coverage
1 Tape Bare Copper (BC) 100%
2 Braid Tinned Copper (TC + Tin Filled) 100%
Overall Cable Diameter (Nominal): 0.246 in (6.25 mm)
Electrical Characteristics
Frequency Max. VSWR 400 MHz 1.10:1 1000 MHz 1.11:1 3000 MHz 1.14:1 7000 MHz 1.21:1 10000 MHz 1.25:1 18000 MHz 1.38:1 Attenuation Frequency Nom. Attenuation 400 MHz 3.8 dB/100ft 500 MHz 4.4 dB/100ft 1000 MHz 6.8 dB/100ft
2000 MHz 10.4 dB/100ft
3000 MHz 13 dB/100ft
5000 MHz 19 dB/100ft
7000 MHz 22.8 dB/100ft
10000 MHz 28 dB/100ft
15000 MHz 36.6 dB/100ft 18000 MHz 41.0 dB/100ft Power Rating Frequency Max. Power Rating
400 MHz 1,900 W
500 MHz 1,665 W
1,000 MHz 1,105 W 2,000 MHz 733 W 3,000 MHz 577 W 5,000 MHz 427 W 7,000 MHz 350 W 10,000 MHz 283 W 15,000 MHz 223 W 18,000 MHz 200 W Electricals 2.5 Ohm/1000ft (8.2 Ohm/km) 8.6 Ohm/1000ft (28 Ohm/km) 29.6 pF/ft (97.1 pF/m) 50 Ohm 70% Voltage UL Voltage Rating Voltage Rating
30 V RMS 2900 V RMS
Electrical Characteristics Notes: VSWR limit is a continuous sloping line from 500 MHz to 18 GHz Mechanical Characteristics Temperature UL Temperature Operating 105°C -70°C To +200°C Bend Radius Stationary Min. Installation Min. Flexing Min. Max. Pull Tension: 122 lbs (55.3 kg) Bulk Cable Weight: 81 lbs/1000ft Standards and Compliance Environmental Suitability: Indoor/Outdoor, Indoor, Outdoor AWM Compliance: AWM 10245 European Directive Compliance: EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) APAC Compliance: China RoHS II (GB/T 26572-2011) Product Notes Notes: Commercial non-QPL product History Update and Revision: Revision Number: 0.474 Revision Date: 05-03-2023 Part Numbers Variants Item # Color Putup Type Length UPC Footnote 1675A TIN100 Tin Reel 100 ft 612825120537 E 1675A TIN500 Tin Reel 500 ft 612825120544 C E
© 2024 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.