Thermal automotive Mini-CBE 1620-... www.e-t-a.de2214

Description

Ordering information

Current ratings, typical voltage drop values and colour coding Technical data Single pole, thermal miniaturised circuit breaker designed for automotive applications. Fits into fuse blocks designed to ISO 8820-3, Type F. Automatic reset (for DC 12 V only) and open circuit (modified reset to SAE) version optional. Open circuit version ensures contacts staying open as long as power is on. The circuit breaker will reset after the load is removed. Particularly suitable for installation in inaccessible locations. Current ratings correspond to those of blade fuses. Clear colour coding of the ratings: blade fuse and circuit breaker of the same colour have the same rating. Meets the requirements of SAE J553. US patent number: US 8,576,042,B2 Protection of electrical systems of passenger cars, trucks, buses, watercraft, extra low voltage wiring systems. For further details please see: www.e-t-a.de/ti_e Voltage rating 1620-1/-2: DC 12 V 1620-3: DC 12 V, DC 24 V Max. voltage rating 1620-1/-2: DC 14.5 V 1620-3: DC 29.0 V Current ratings DC 12 V: 5...30 A DC 24 V: 5...25 A Service short-circuit breaking capacity 300 operations at 2 x IN Ambient temperature -40...+85 °C (-40…+185 °F) (for higher temperatures please enquire) Reset period for 1620-1 (at 23 °C) ≤ 15 s Reset period for 1620-2 (at 23 °C) after 5 sec at rated voltage < 35 s Degree of protection (IEC 60529) operating area IP40 (-3) operating area IP50 (-1, -2) terminal area IP00 Ultimate short-circuit breaking capacity ≥ 3 break operations at 150 A, or ≥ 1 break operation at 2,000 A Vibration 10 g (57-500 Hz), ± 0.38 mm (10-57 Hz) to IEC 60068-2-6, test Fc 10 frequency cycles/axis Shock 50 g (11 ms) to IEC 60068-2-27, test Ea Corrosion 48 hrs in 5 % salt mist, to IEC 60068-2-11, test Ka Humidity 240 hrs in 95 % RH, to IEC 60068-2-78, test Cab Mass approx. 3 g Caution: It is good practice to switch off the vehicle’s ignition system before manually releasing or re-setting the circuit breaker. Free travel of the reset button must be ensured! Please ensure to push in the actuator smoothly and completely. Depending on the socket used and with the 30 A device carrying a full load, the temperatures at the terminals may rise above the allowed SAE value. Type No. 1620 single pole thermal Mini-CBE with standard characteristic curve Version, according to SAE J553 1 type 1, automatic reset 2 type 2, modified reset 3 type 3, with reset button Current ratings 5 7.5 10 15 20 25 30 A 1620 - 1 - 10 A ordering example Please be informed that we have minimum ordering quantities to be observed. Current rating (A) Voltage drop (mV) Housing cap colour 5 < 150 light brown 7.5 < 150 brown 10 < 150 red 15 < 150 blue 20 < 150 yellow 25 < 150 white 30 < 150 light green SAE type 1 SAE type 2 SAE type 3 Note The circuit breakers are marked with current rating, type and maximum voltage. Special machine readability is not guaranteed.

Thermal automotive Mini-CBE 1620-... www.e-t-a.de 2214 The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section Technical information. Ambient temperature °F Ambient temperature °C -40 -40 -22 -30 -20 +14 -10 +32 +50 +10 Ambient temperature °F Ambient temperature °C +73.4 +23 +104 +40 +122 +50 +140 +60 +158 +70 +185 +85 5...30 A -40 °C +85 °C +23 °C 10000 1000 100 0.1 0.4 0.60.812 4 6 8 10 20 40 times rated current trip time in seconds 1620-1 / 1620-2 2.8 .110 0.8 .032 .276 3.8 .14910.9 .429 12.7 .500 4.5 .177 GERMANY 13.3 .524 2.8 11.6 .457 10.4 .409 .295 7.5 .079 .984 1620-3 .079 0.8±0.5 ON .031±.019 ON 4.5±0.5 OFF .177±.019 OFF 3.5 .138 0.6 .0241.8 .071 GERMANY 13.3 .524 11.6 .457 .079 .984 1620-3H 3.5 .138 13.3 .524 .275 4.8 .189 30.2 1.19 0.8±0.5 ON .031±.019 ON 24.95 .982 4.5±0.5 OFF .177±.019 OFF 11.6 .457 GERMANY Dimensions Internal connection diagrams Typical time/current characteristic curve at +23 °C / +73.4 °F All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. This ist a metric design and millimeter dimensions take precedence (mm inch) 1620-1 1620-3 1620-3H 1620-2