www.e-t-a.de 1942 Thermal Automotive Circuit Breaker 1616-...

Description

Ordering information Technical data Miniaturised single pole press-to-reset cycling type trip-free circuit breaker designed for installation in the E-T-A socket type 12 or fuse blocks to ISO 8820-3. The current ratings available correspond to those of blade fuses to facilitate interchangeability. For further convenience the same colour coding system is used thereby ensuring that circuit breakers and fuses of the same rating are identified by the same colour marking. Breakers rated 7.5 A through 40 A have a fast characteristic curve and only hold 70 % of their rated current continuously. Extra low voltage wiring systems on all types of vehicles and marine craft. 1616-21 1616-H2 1616-92 For further details please see: www.e-t-a.de/ti_e Voltage rating 1616-92: DC 12 V 1616-21/1616-H2: DC 32 V Current ratings 5 A (medium delay) 7.5...40 A (fast trip) Service short-circuit breaking capacity 300 operations at ≤ 50 A Ambient temperature -40...85 °C Reset period for 1616-92 (at 23 °C) ≤ 15 s Degree of protection operating area IP30 (-21/-H2) (IEC 60529/DIN 40050) operating area IP54 (-92) terminal area IP00 Ultimate short-circuit breaking capacity ≥ 3 break operations at 150 A, or ≥ 1 break operation at 2,000 A Vibration (with mounting socket 12) 10 g (57-500 Hz) ± 0.38 mm (10-57 Hz) to IEC 60068-2-6, test Fc 10 frequency cycles/axis Shock (with mounting socket 12) 50 g (11 ms) to IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH, to IEC 60068-2-3, test Ca Mass approx. 5 g Caution: Free travel of the reset button must be ensured! Please ensure to push in the actuator smoothly and completely. Type No. 1616 single pole automotive circuit breaker Version

21 DC 28 V without manual release facility

H2 DC 28 V with manual release facility

92 DC 12 V autoreset (type I to SAE J 553)

5 7,5 10 15 20 25 30 40 A 1616 - 21 - 10 A ordering example Please be informed that we have minimum ordering quantities to be observed. Current ratings, typical voltage drop values and colour coding Current rating (A) Voltage drop (mV) Housing cap colour 5 < 150 light-brown 7.5 < 150 brown 10 < 150 red 15 < 150 blue 20 < 150 yellow 25 < 150 white 30 < 150 light-green 40 < 150 orange Trip times at rated current Trip times at ... x rated current 1,1 x IN 1,35 x IN 2,0 x IN 3,5 x IN 6,0 x IN 5 light brown 3600 s 3600 s 40 s 3600 s 3 s 20 s 0,8 s 2 s 0,2 s 0,5 s 7,5 brown 10 s 3600 s 5 s 120 s 1 s 10 s 0,3 s 2 s 0,2 s 0,5 s 10 red 10 s 3600 s 5 s 120 s 1 s 10 s 0,3 s 2 s 0,2 s 0,5 s 15 blue 10 s 3600 s 5 s 120 s 1 s 10 s 0,3 s 2 s 0,2 s 0,5 s 20 yellow 10 s 3600 s 5 s 120 s 1 s 10 s 0,3 s 2 s 0,2 s 0,5 s 25 white 10 s 3600 s 5 s 120 s 1 s 10 s 0,3 s 2 s 0,2 s 0,5 s 30 light green 25 s 3600 s 10 s 120 s 3 s 12 s 0,8 s 2,6 s 0,2 s 0,8 s 40 orange 25 s 3600 s 10 s 120 s 3 s 12 s 0,8 s 2,6 s 0,2 s 0,8 s IN = rated current / The trip times comply with ISO 10924-4. Note The circuit breakers are marked with current rating, type and maximum voltage. Special machine readability is not guaranteed.

Thermal Automotive Circuit Breaker 1616-... www.e-t-a.de 1942 10000 1000 100 0,1 0,4 0,8 12 46 81 02 04 0 Trip time in seconds times rated current 7.5...40 A + 23 °C + 85 °C - 40 °C 1616-H2 0.6 3.3 3.9 7.5 Please leave space for button travel 2.7 1616-21 1616-92 .236 .106 .295 .024 4.5 5.2 6.4 14.5 16.6 18.8 .205 .571 .654 .740 .252 .787 .945 .130 .154 .177 .157 ±.020 .031±.020 OFF ON 4±0.5 0.8±0.5 .118 6.4 .252 OFF ON 0.6 7.5 .295 5.2 3.4 29.5 4.524 14.5 16.6 7.3 18.8 3.3 3.9 .571 .654 .740 .787 .177.945 .236 .024 .130 .154 Please leave space for button travel .118 .134 .287 .205 20 6 5.2 14.5 16.6 18.8 0.6 3.3 7.5 19.2 3.9 .295 .236 .571 .654 .740 .205 .787 .945 .024 .130 .039 .756 .154 6.4 .252 .157 ±.020 .031±.020 4±0.5 0.8±0.5 1.16 1616-H21616-21 1616-92 Dimensions Internal connection diagrams Typical time/current characteristic curve The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also sec- tion Technical information. Ambient temperature °F -40 -22 -4 +14 +32 +50 °C -40 -30 -20 -10 0 10 Derating factor 0,73 0,78 0,82 0,86 0,91 0,95 Ambient temperature °F +73.4 +104 +122 +140 +158 +185 °C 23 40 50 60 70 85 Derating factor 1 1,09 1,16 1,25 1,33 1,43

www.e-t-a.de 1942 Thermal Automotive Circuit Breaker 1616-... Thermal Automotive Circuit Breaker 1616-... Accessories for mounting socket 12 Accessories terminal screw 6-32 UNC tightening torque max. 1.2 Nm blade terminal DIN 46244-A6.3-0.8 (QC .250) symmetrical hat rail EN 50022-35x7.5 Weidmüller style label (not supplied) 3.5 25.4 ø3.948 spring washer 32.6 12.7 1.00 1.29 1.69 1.85 2.28 .138.154 1.89 .500 symmetrical hat rail EN 50022-35x7.5 Weidmüller style label (not supplied) terminal screw 6-32 UNC tightening torque max. 1.2 Nm spring washer 3.5 25.4 32.6 ø3.9 12.7 1.00 1.29 1.69 1.85 2.28 .138.1541.89 .500 blade terminal DIN 46244-A6.3-0.8 (QC .250) symmetrical hat rail EN 50022-35x7.5 3.5 25.4 32.6 ø3.9 12.7 Weidmüller style label (not supplied)1.00 1.29 1.69 1.85 2.28 .138.154 1.89 .500 .512 .157 1.89 2.36 .276 Socket 12-P10 Socket 12-J20 Socket 12-A10 Dimensions for surface mounting Other sockets available to special order Labels: Weidmüller, D-33102 Paderborn Ordering information Mounting socket 12 Connector bus links -P10 X 210 588 01/ 1.5 mm2 (AWG 16), brown (up to 13 A max. load) X 210 588 02/ 2.5 mm2 (AWG 14), black (up to 20 A max. load) X 210 588 03/ 2.5 mm2 (AWG 14), red (up to 20 A max. load) X 210 588 04/ 2.5 mm2 (AWG 14), blue (up to 20 A max. load) 210 12.87 154.8 cylinder head screw ISO1207-M4x4 nickel plated washer A 4.3 DIN 125 nickel platedmax.cross section 35 mm2 (AWG 2) fusible link 1.1mm (.043 in.) thick constriction) Cu rail, tin-plated.079.394 6.09 .504.276 Bus bar (supplied as a complete package) (up to 100 A max. load) X 211 157 01 with terminal X 211 157 02 without terminal~70 100 quick-connect tabs 6.3 (.250) DIN 46247 tinned brass, insulated ~2.76 Type No.

12 Mounting socket

P10 blade terminals A 6.3-0.8 (QC .250) J20 screw terminals 6-32 UNC A10 1 blade terminal A6.3-0.8 (QC .250) / 1 screw terminal 6-32 UNC Version (blank) single socket 20 two-way 30 three-way 40 four-way 60 six-way 12 - P10 - 20 ordering example Labels: Weidmüller, D-33102 Paderborn This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted.

Thermal Automotive Circuit Breaker 1616-... www.e-t-a.de 1942