15HM SENSATA | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 3
Technical content
www.sensata.com Copyright © 2018 Sensata Technologies, Inc. 15HM SERIES | MOTOR PROTECTORS Hermetically Sealed Single Phase On Winding Protection SPECIFICATIONS Features and Benefits Product Description Line Break Operation
- High Reliability – 2 contact ratings
- Optional start winding protection
- Compact and rugged construction
- Meet rotary compressor high side pressure requirements
- Application range – 1 to 5 HP The 15HM family of motor protectors can be applied to unitary air conditioning and heat pump compressors ranging from 1 to 5 HP. They may also be used in commercial motors which must function in destructive or corrosive environments. Its compact and rugged design make it resistant to mechanical shock and suitable for installation directly on motor windings. Klixon® 15HM motor protectors are line break automatic reset controls which are wired in series with and mounted on the motor windings. These protectors track winding temperatures and respond to changes in line current to afford protection against the wide variety of overload conditions listed below:
- Running overload • High/low voltage locked rotor
- Loss of refrigerant charge • Shorted capacitor
- High discharge temperature Open Temperature 90ºC - 150ºC Tolerance ±5ºC Open, ±9ºC Close Series Start Winding Line Voltage Locked Rotor Current HP Range 300 13XX 23XX Yes No 230V *100 Amp *1 - 3 1/2 600 16XX 26XX Yes No 230V *140 Amp *3 1/2 - 5 Protector Ratings * To be used as a guide for selection only, consult factory for specific life test data
www.sensata.com Page 2 Copyright © 2018 Sensata Technologies, Inc. Metric Dimensions in Parenthesis DIMENSIONS .068 MAX. (1.73) .089 DIA. ±.005 (2.26) .260 ±.010 (6.60) COPPER CORED PIN GLASS SEAL .880 ±.015 (22.35) .643 ±.016 (16.33) .674 ±.005 (17.12) .571 ±.010 (14.50) .206 ±.016 (5.23) WELDED ALL AROUND .410 R ± .010 (10.41) .460 ± .010 (11.68) 1.300 ± .030 (33.02) WHITE .704 ± .005 (17.88) RED .088 ± .005 (2.24) Circut Diagram START WDG 12R MAIN WDG 12R LOCATION AMBIENT START WDG 12R MAIN WDG 12R LOCATION AMBIENT START WDG 12R MAIN WDG 12R LOCATION AMBIENT START WDG 12R MAIN WDG 12R LOCATION AMBIENT RUNNING OVERLOAD (ULTIMATE TRIP) LIGHT LOAD LOCKED ROTOR CONTINUOUS START CIRCUITING 130ºC 25ºC 0ºC 130ºC 25ºC 0ºC SW MW S C R SWR MWH 15HM Heat Input Relationships
ORDERING OPTIONS Example : 15HM Y XXX-ZZZ Product Family Nomenclature Denotes with or without Start Winding Heater Electrical Characteristics Code (Series) Physical Configuration Code 15HM Y XXX ZZZ Agency File Number UL / C-UL E15962 DEKRA (ENEC) 2018218.05 CQC CQC03002007249 AGENCY APPROVALS & CERTIFICATIONS Page 3 Rev:04/12/23 www.sensata.com CONTACT USCopyright © 2023 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Americas +1 (508) 236-2551 electrical-protection-sales@sensata.com Europe, Middle East & Africa +1 (760) 597 7042 support@sensata.com Asia Pacific EP_Asia_Public@list.sensata.com China +86 (21)2306 1651 Japan +81 (45)277 7104 Korea +82 (53) 644 9685 India +91 (40)4033 9611 Rest of Asia +603-5566 6001