156A ADVANCEDENERGY | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

©2020 Advanced Energy Industries, Inc. The Trek® 156A tests the efficiency of an ionizer’s ion production by timing how long it takes air ions produced to discharge a floating plate that has been pre-charged to either a positive or negative value. The Trek 156A also tests the balance between positive and negative air ions by measuring the offset voltage generated on a floating plate due to an imbalance of positive and negative air ions impinging on the plate from the ionizer. PRODUCT HIGHLIGHTS  Customizable measurement capacitance provides assurance that ESD process needs are met in manufacturing and that there is compliance to ANSI/ESD-STM3.1 and IEC 61340-5-1.  Extremely low offset and drift ensures high accuracy, making it ideal for applications requiring critical ion balance such as GMR and TMR manufacturing areas  Compact and lightweight, for easy portability within a facility  NIST-traceable Certificate of Calibration provided with each unit

APPLICATIONS

 ESD monitoring of sensitive manufacturing processes such as semiconductor, disk drive and LCD  Testing of all types of ionizers, including room ionization systems, AC and DC blowers, nuclear ionizers, gun type ionizers, and pulsed DC ionizers  High temperature applications  ESD measurement of de-ionized water  Dissipative testing applications Large Signal Bandwidth DC to 10 Hz Decay Mode Thresholds Start/Stop Voltages Programmable from 1 to ±1000 V in 1 V increments Start/Stop Accuracy Within ±1 V of programmed voltage AT A GLANCE TREK 156A Charged plate monitor for evaluating the performance of air ionizers used to neutralize static charges.

2 advancedenergy.com TREK CHARGED PLATE MONITOR 156A TECHNICAL DATA Performance Specifications Monitored Voltage Range 0 to ±1100 VDC or peak AC Large Signal Bandwidth DC to 10 Hz (measured at 2000 V p-p) Small Signal Bandwidth DC to 1 kHz (measured at 20 V p-p) (-3dB) Zero Stability (referred to plate voltage) Drift with Time (no incident ion flow) Less than 6 V/minute Drift with Temperature Less than 10 mV/°C, noncumulative Decay Mode Thresholds Start Voltage Programmable from 1 to ±1000 V in 1 V increments Stop Voltage Programmable from 0 to ±999 V in 1 V increments Start/Stop Accuracy Within ±1 V of programmed voltage Discharge Time Resolution 0.1 seconds, from 0.1 to 999.9 seconds; 1 second, from 1000 to 9999 seconds. (The display will indicate “- - - -” when the decay time exceeds 9999 seconds.) Plate Self-Discharge Rate Less than 12 V/minute Voltage Monitor Output BNC provides low voltage replica of plate Scale Factor 1/200th of the plate voltage DC Accuracy Better than 0.1% of full scale Offset Voltage Less than ±10 mV Output Noise Less than 10 mV rms Output Impedance Less than 0.1Ω Mechanical Specifications Dimensions (H x W x D) 83 x 318 x 280 mm (3.25 x 12.5 x 11 in) Weight 2 kg (4.4 lb) Connections Voltage Monitor BNC Connector Ground Receptacle Banana Jack Cable 156A to Plate Coaxial (3 m length, 4.95 mm diameter) Electrical Specifications Battery Eliminator Output Connector 2.1 mm DC power plug Output Current 1.2 A Battery Operation Rechargeable battery, supplied Recharge Time 2.1 mm DC power plug Recharge Indicator LCD screen battery status indicator Operating Time 8 hours from a full charge Environmental Specifications Temperature 5 to 35°C (41 to 95°F) Relative Humidity To 80% RH, noncondensing Altitude To 2000 m (6561.68 ft.) Measured using the true rms feature of the HP Model 34401A digital multimeter

advancedenergy.com 3 TREK CHARGED PLATE MONITOR 156A Included Accessories

23103 Operator’s Manual

F5054R Universal AC Adapter Optional Accessories

43433 Carrying Case

1K062 Walking Test Adapter 1K065 Ion Collecting Plate Tripod Kit Ion Collecting Plates Capacitance: 20 pF ±2 pF 17397 150 x 150 mm (6 x 6 in sq) 17375 25 x 25 mm (1 x 1 in sq) REFERENCE NUMBERS TECHNICAL DATA (CONTINUED)

Features

Mode Select A three-position toggle switch selects the +Decay, -Decay, or Float mode of operation. This switch is also used in combination with the Test/Reset Control switch to program the START and STOP voltages. Test/Reset Control A momentary toggle switch used in conjunction with the Mode Select switch to program the START and STOP voltages +Decay and -Decay Modes Sets the plate voltage to a value greater than the programmed start voltage and resets the decay timer to zero Float Mode Sets the plate voltage to 0 V ±2 V Plate Voltage Digital Panel Meter 3.5 digit red LED display Range 0 to ±1100 V Resolution 1 V Accuracy Better than 0.1% of full scale ±1 count Decay Time Digital Panel Meter 4-digit red LED display Range 0 to 9999 seconds

For international contact information, visit advancedenergy .com. sales.support@aei.com +1.970.221.0108 ABOUT ADVANCED ENERGY Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. AE’s power solutions enable customer innovation in complex semiconductor and industrial thin film plasma manufacturing processes, demanding high and low voltage applications, and temperature-critical thermal processes. With deep applications know-how and responsive service and support across the globe, AE builds collaborative partnerships to meet rapid technological developments, propel growth for its customers and power the future of technology. Specifications are subject to change without notice. Not responsible for errors or omissions. ©2020 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, Trek®, and AE® are U.S. trademarks of Advanced Energy Industries, Inc. ENG-ESD-Trek-156A-235-02 12.20