Doc #97025 DATA DELAY DEVICES, INC. 2/6/97 3 Mt. Prospect Ave. Clifton, NJ 07013 10-TAP SIP DELAY LINE TD/TR = 5 (SERIES 1507)
FEATURES
10 taps of equal delay increment Very narrow device (SIP package) Stackable for PC board economy Low profile Epoxy encapsulated Meets or exceeds MIL-D-23859C FUNCTIONAL DESCRIPTION The 1507-series device is a fixed, single-input, ten-output, passive delay line. The signal input (IN) is reproduced at the outputs (T1-T10) in equal increments. The delay from IN to T10 (TD) is given by the device dash number. The characteristic impedance of the line is given by the letter code that follows the dash number (See Table). The rise time (TR) of the line is 10% of TD, and the 3dB bandwidth is given by 3.5 / TD. SERIES SPECIFICATIONS Dielectric breakdown:
50 Vdc
Distortion @ output: 10% max. Operating temperature: -55°C to +125°C Storage temperature: -55°C to +125°C Temperature coefficient:
100 PPM/°C
.250 MAX. .100 MIN. 1.455 TYP. .200 MAX. .020 TYP. .020 TYP. 1.300 TYP. .100 TYP. .010 TYP. Package Dimensions 1997 Data Delay Devices data delay devices, inc. GND IN T1 T2 T3 T4 9 10 11 12 13 14 NC T10 T6 T7 T8 T9 GND 1507-xxz xx = Delay (TD) z = Impedance Code PIN DESCRIPTIONS IN Signal Input T1-T10 Tap Outputs GND Ground DASH NUMBER SPECIFICATIONS Part Number TD (ns) Delay per Tap (ns) TR (ns) Impedance (ΩΩ) RDC (ΩΩ) 1507-20A 20.0 ± 2.0 2.0 ± 0.4 4.0 1.0 1507-40A 40.0 ± 2.0 4.0 ± 1.0 8.0 1.5 1507-50A 50.0 ± 2.5 5.0 ± 1.5 9.0 1.5 1507-100A 100 ± 5.0 10.0 ± 2.0 18.0 2.0 1507-150A 150 ± 7.5 15.0 ± 2.0 28.0 3.0 1507-200A 200 ± 10.0 20.0 ± 3.0 38.0 4.0 1507-20B 20.0 ± 2.0 2.0 ± 0.4 4.0 100 1.5 1507-50B 50.0 ± 2.5 5.0 ± 1.5 9.0 100 2.0 1507-100B 100 ± 5.0 10.0 ± 2.0 18.0 100 4.0 1507-200B 200 ± 10.0 20.0 ± 3.0 38.0 100 6.0 1507-250B 250 ± 13.0 25.0 ± 4.0 48.0 100 7.0 1507-20C 20.0 ± 2.0 2.0 ± 0.4 4.0 200 3.0 1507-50C 50.0 ± 2.5 5.0 ± 1.5 9.0 200 4.5 1507-100C 100 ± 5.0 10.0 ± 2.0 18.0 200 6.0 1507-200C 200 ± 13.0 20.0 ± 3.0 38.0 200 9.0 1507-50G 50.0 ± 2.5 5.0 ± 1.5 9.0 500 6.0 1507-100G 100 ± 5.0 10.0 ± 2.0 18.0 500 10.0 1507-200G 200 ± 10.0 20.0 ± 3.0 38.0 500 30.0 1507-300G 300 ± 15.0 30.0 ± 4.0 58.0 500 30.0 1507-500G 500 ± 25.0 50.0 ± 5.0 98.0 500 55.0 Functional Diagram GND IN T10 GND
Doc #97025 DATA DELAY DEVICES, INC. 2/6/97 Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com PASSIVE DELAY LINE TEST SPECIFICATIONS TEST CONDITIONS INPUT: OUTPUT: Ambient Temperature: 25oC ± 3oC Rload: 10MΩ Input Pulse: High = 3.0V typical Cload: 10pf Low = 0.0V typical Threshold: 50% (Rising & Falling) Source Impedance: 50Ω Max. Rise/Fall Time: 3.0 ns Max. (measured at 10% and 90% levels) Pulse Width (TD <= 75ns): PWIN = 100ns Period (TD <= 75ns): PERIN = 1000ns Pulse Width (TD > 75ns): PWIN = 2 x TD Period (TD > 75ns): PERIN = 10 x TD NOTE: The above conditions are for test only and do not in any way restrict the operation of the device. Timing Diagram For Testing TRISE TFALL PERIN PWIN TRISE TFALL 10% 10% 50% 50% 90% 90% 50% 50% VIH VIL VOH VOL INPUT SIGNAL OUTPUT SIGNAL TRISE TFALL 10% 10% 90% 90% IN OUT TRIG IN TRIG Test Setup DEVICE UNDER TEST (DUT) OSCILLOSCOPE PULSE GENERATOR 50 Ω ROUT RIN RIN = ROUT = ZLINE T10