HFE80V-200_EN Rev 1.0 1 A HFE80V-200 HIGH VOLTAGE DC RELAY
- 200A, 250Vdc - 1 Form A Relay
- 4kVac dielectric strength between coil and contacts
- Different control coil voltages: 12, 24Vdc
- Outline Dimensions: (54x29.6x88) mm
- Dimensions with flanges: (88x47.4x88) mm
- Screw load terminals
- Mounting flanges reinforced with compression sleeves
- RoHS compliant materials and processes Contact Data Characteristics Rated Load 200A Insulation resistance 1,000MΩ (at 500 Vdc) Contact form 1 Form A Dielectric strength: Contact material Cu Alloy Coil to contact 4kVac for 1 min Contact resistance* ≤1mΩ (@ 20A) Across open contacts 3kVac for 1 min Max. switching voltage 250Vdc Dielectric creepage Max. switching current 400A Ambient temperature -40°C to +85°C Operate time ≤ 30ms Ambient humidity 5% - 85% RH Release time ≤ 10ms Vibration 1.5 mm (DA) 10Hz to 500Hz † Bounce time ≤ 5ms Shock resistance: Electrical endurance 10,000 cycles ‡ Functional 196 m/s 2 § Mechanical endurance 200,000 cycles Destructive 490 m/s 2 ** Coil power consumption 6W Termination: Coil termination Connector Load termination Screw Terminal Unit weight Approximately 370g * Typical value for Initial Contact Resistance: Using a sample quantity of at least 20 units, take the average value from 5 continuous measurements from each sample † Sinusoidal vibration, 1.5 mm double amplitude ,10 Hz to 500 Hz, acceleration 49 m/s2, 8 hours each for both directions on of three mutually perpendicular axes, 4 hours each for the energized and non-energized status, total 24 hours. There shall not be any abnormalities on relay appearance, construction and performance ‡ Rating at: 200Vdc / 40A. Duty Cycle: On: 0.6s, Off: 5.4s § Duration 11ms, 500 ops for each direction of three mutually perpendicular axes, 250 ops each for the energized and non- energized status, total 3000 shocks. The opening time for close contacts or the closing time for open contacts should not exceed 10μs ** Duration 6 ms, 50 shocks for each direction of three mutually perpendicular axes, total 300 shocks. There shall not be any abnormalities on relay appearance, construction and performance
HFE80V-200_EN Rev 1.0 2 A Current Endurance†† Current Duration 200A Continuous 300A 5 min 400A 30 s 800A 10 s 1600A 1 s †† Testing Conditions: 1V, 85°C, Diameter of cable used: 60 mm2 Electrical Endurance‡‡ Contact Rating Operations Making Current Inrush 400A, RC =1ms, Steady 200A, 10Vdc, Breaking Current 0A 75,000 ops Making Current 40A, Breaking Current 40A, 200Vdc 10,000 ops Making Current 100A, Breaking Current 100A, 200Vdc 5,000 ops Making Current 150A, Breaking Current 150A, 200Vdc 1,500 ops Making Current 200A, Breaking Current 200A, 200Vdc 500 ops Breaking Current 200A, 150Vdc, Making Current 0A 3,000 ops Breaking Current 400A, 200Vdc, Making Current 0A 50 ops ‡‡ 23oC room temperature, Duty Cycle 0.6s ON/ 5.4s OFF, Diameter of cable used: 60 mm2 Coil Resistance (Ω±10%) at 23°C Nominal Coil Voltage Pick-up Voltage Drop-out Voltage Coil Resi stance 12Vdc ≤9Vdc ≥1Vdc 24Ω 24Vdc ≤18Vdc ≥2Vdc 96Ω
Ordering Information
HFE80 V -200 /■ -■ -H T C 5 Y (XXX) Type Application V : Vehicle Nil : New Energy Power Control Series Code 200 : 200A Load Voltage 150 : 150Vdc 200 : 200Vdc Coil Voltage 12 : 12Vdc 24 : 24Vdc Contact Type H : 1 Form A Contact Material T : AgSnO2 Coil Termination C : Connector Load Terminal 5 : Screw Terminal Installation Type Y : Horizontal Fixing Nil : Vertical Fixing Special Code X : Customer Customization
HFE80V-200_EN Rev 1.0 3 A D i m e n s i o n a l D r a w i n g s (Unit: mm) VERTICAL FIXING : HFE80V-200/XXX-XX-HTC5 (XXX) HORIZONTAL FIXING : HFE80V-200/XXX-XX-HTC5Y (XXX)
HFE80V-200_EN Rev 1.0 4 A Wiring Diagrams Single Coil 1. Coil and load terminals are polarity independent Connector Manufacturer: Tianhai, Part number: 0435 §§ §§ Connectors are optional parts
HFE80V-200_EN Rev 1.0 5 A Application Notes 1. To maintain the relay in its closed state, the coil voltage should reach the stated pick-up voltage. 2. For definitions of terms used in this data sheet, see glossa ry at www.kgtechnologies.net. Disclaimer: This data sheet is for reference only. All specifications are s ubject to change without prior notice. KG Technologies, Inc. cannot predict every possible application for our relays. While we do our best to make our relays as versatile as possible, we highly recommend contacting our en gineering team if you have any questions. KG Technologies, Inc. is not responsible for malfunctioning relays when operated outside the specified parameters given in this data sheet.