Features

  • Compatible with any UL Listed fire alarm control panel.
  • 50 watt power output.
  • 25 or 70.7 (optional) VRMS power-limited operation.
  • Integral message repeater.
  • Eight (8) DIP-switch selectable tones. - ANSI Cadence - Alert Tone - March Code - Hi-Lo - California Code - ANSI Whoop - Steady - Continuous Whoop
  • Optional FVIV-ZS provides four Style Y or Z (Class A or B) speaker circuits.
  • Auxiliary audio input.
  • Form “C” trouble and alarm relay outputs.
  • Remote microphone module for all-call paging.
  • Single channel operation. FireVac® IV An ISO 9000-2000 Company SIGNALING

12 Clintonville Road, Northford, CT 06472 - Tel: 203-484-7161 - Fax: 203-484-7118

www.gamewell.fci.com 9020-0532 Rev. D1 page 2 of 4 FVIV-X70 The FVIV-X70 optional module is used to convert the standard speaker circuit voltage output from 25 VRMS to 70 VRMS. This is useful in situations where the speakers circuits must run for longer distances. Note that speakers at 70 VRMS are not power-limited and must be separated from power-lim ited circuits by at least 1/4 inch. FVIV-RM The FVIV-RM Remote Microphone Station enhances operation of t he system by provid- ing voice paging from a remote location up to 5,000 feet away. Only four wires (shielded,

18 AWG minimum) are required between the

®IV and the FVIV-RM. The FVIV-RM is fully supervised by the FireVac ®IV. Simply key the microphone to activate the Fire- Vac®IV in an “ALL-Call” fashion to page over all speakers. The FVIV-RM comes complete with its own cabinet with dimensions of 10 1/4” H x 10 3/8” W x 3 1/8” D (26.04 x 26.35 x 7.94 cm). System Operation The operation of a fire alarm initiating device (i.e. smoke detectors, manual stations, water-flow switches, etc.) connected to the fire alarm control panel will cause a either a reverse polarity signal or a dry contact closure to be sent to the FireVac ®IV. If the optional FVIV-ZS is installed, the fire alarm control panel will also provide up to four normally open dry contact outputs that will close to activate the appropriate speaker circuit. In response, the FireVac ®IV will: 1. Sound an alarm tone (DIP switch selectable) over the speaker circuit(s). 2. Produce a recorded message that will play in alterna- tion with the selected tone. 3. Override both tone and pre-recorded message and broadcast voice commands from the local or remote microphones. The FireVac ®IV provides two (2), separate mes- sages that may be field configured using the op- tional 7780 program. Optional Modules (FVIV-ZS) An ideal solution for installations that require zoned speaker circuit activation, the FVIV-ZS provides four separate, individually activated speaker cir- cuits. The FVIV-ZS features a switch for manual activation of each speaker circuit as well as an ad- dition switch for “All-Call” paging. Interface with the fire alarm control panel is achieved through normally open relays provided by the main control panel. The FVIV-ZS responds to closures across its input terminals to activate the appropriate speaker circuit. SP + SP – SP 4+ SP 4– SP R4+ SP R4– SP 3+ SP 3– SP R3– SP R3+ SP 1+ SP 1– SP R1+ SP R1– SP 2+ SP 2– SP R2+ SP R2– ALL-CALL ACTIVE TROUBLE –+ OUT –+ IN

70.7 VRMS SPK

www.gamewell.fci.com 9020-0532 Rev. D1 page 3 of 4 FVIV-RM (in Cabinet up to 5,000 feet way) FireVac® IV Assembly

www.gamewell.fci.com 9020-0532 Rev. D1 page 4 of 4

Ordering Information

150-00026 FireVac®IV, Emergency Voice Evacuation System, 50 watts”Stand Alone” 150-00027 FVIV-50-ZS, Emergency Voice Evacuation System, 4-channel, 50 watt total 151-00027 FVIV-RM, Remote Microphone Station (one per system) 151-00028 FVIV-X70, Line Transformer, con- verts 25 VRMS speaker circuit(s) to

70 VRMS

151-00029 FVIV-B450, Zone Splitter, 4 Speaker Circuits 200-90002 7780, Programming Software to download or removerecorded messages Specifications Operating voltage: 120 VAC @ 60 Hz, 1.2 amp, or 230 VAC @ 50 Hz, 0.607 amp.* Operating temperature: 32° to 120° F (0° to 49° C) Relative humidity: 10% to 85% at 86° F (30°C), non- condensing * Specify voltage requirements when ordering. Operating Current Supervisory Alarm FireVac IV 0.140 amp. 0.490 amp. FVIV-ZS 0.045 amp. 0.250 amp. (All circuits active) FVIV-RM 0.030 amp. 0.030 amp. FVIV-X70 0.010 amp. 0.065 amp. Trouble & Alarm Relays 2.5 A @ 30 VDC resistive Dimensions: Surface mount 26 1/4” H x 14 1/2” W x 4” D (67 x 36.3 x 8.8 cm) Flush mount 24 3/4” H x 14 1/2” W x 3 7/16” D (63 x 36.3 x 8.7 cm) Shipping weight 37 lbs. (16.78 kg.)