DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 7
Technical content
03-2012, Rev. 0312 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. AXICOM Signal Relays n Strong magnet system and wide voltage range n Highly reliable n Contacts for signal loads and currents up to 5A n DC coils operating voltage 6VDC to 220VDC; AC, latching and non- latching coils on request n Multi purpose relay n Great variety of contact arrangements and materials to meet specific applications n Sockets for easy and quick mounting of relays Typical applications Press controls with high safety requirements (forcibly guided springs), traffic and railroad signalling, motor vehicle traffic controls, power plants and nuclear power plants controls Max. DC breaking capacity, contact sets B1xx, C1xx Max. DC breaking capacity, contact sets F1xx Cradle S Relay V23054/V23062 Contact Data Product code block 3 B104/B110/ B604/B610/ C104/C110/ C404/C410/ F104/F105/ B112/B133 B612/B633 C112/C133 C422/C433 F110 Contact arrangement max. 6 form C (6 CO) contacts or 6 form A (6 NO) contacts (see product code table) Max. switching voltage 150VDC 36VDC 150VDC 36VDC 260VDC 125VAC 30VAC 125VAC 30VAC 250VAC Rated current 2A 0.2A 2A 0.2A 5A Limiting continuous current at max. ambient temperature 2A 2A 2A 2A 5A Breaking capacity max. 35 to 70W 5W, 5VA 35 to 70W 5W, 5VA 50 to 140W see DC load breaking capacity curve below 50VA - 50VA - 500VA Contact material silver, gold-flashed gold F silver, gold-flashed gold F silver, gold-flashed Contact style single contact single contact bifurcated contacts bifurcated contacts single contact Operate / release time typ. 16/2ms 16/2ms 16/2ms 16/2ms 16/2ms 70 W 40 W 150 120 100 U 0,3 0,4 0,5 0,6 0,8 1 1,5 2A IDC current [A] DC voltage [VDC] safe breaking, no stationary arc contact material Ag, gold flashed 250 200 150 100 100 W 140 W 50 W 0,2 0,3 0,4 0,5 0,6 0,8 1 1,5 2 3 4 5A I U DC current [A] DC voltage [VDC] safe breaking, no stationary arc contact material Ag, gold flashed
03-2012, Rev. 0312 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. AXICOM Signal Relays Cradle S Relay V23054/V23062 (Continued) Coil Data Magnetic system neutral Coil voltage range 6 to 220 VDC, 1000 - 2000mW power consumption Max. coil temperature 100 °C Thermal resistance < 40K/W Coil versions, DC coil, monostable Coil Rated Operate/Limiting Coil Rated coil code voltage voltage1) resistance power VDC VDC Ω ± 10% mW 011 6 - 33 1091 012 8.4 - 70 1008 015 12 - 130 1108 016 12.5 - 185 845 017 16 - 270 948 019 20 - 390 1026 020 24 - 630 914 002 1.2 - 1.75 823 025 28 - 800 980 046 29 - 890 945 021 32 - 1050 975 022 45 - 1900 1066 026 60 - 3800 947 014 76 - 5800 996 004 110 - 9200 1315 013 125 - 15500 1008 003 220 - 25000 1936 1) See part code table. All figures are given for coil without pre-energization, at ambient temperature +23°C. Insulation Data B1xx,B6xx,C1xx,C4xx F1xx Initial surge withstand voltage between open contacts 500Vrms 500V rms between contact and coil 500Vrms 1000V rms between adjacent contacts 500Vrms 1000V rms Initial insulation resistance, at 500VDC > 106Ω Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at www.te.com/customersupport/rohssupportcenter Ambient temperature -40 to +70°C Category of environmental protection IEC 61810 RT I - dust protected, RT V - hermetically sealed Degree of protection, IEC 60529 dust-protected IP 30, or hermetically sealed IP 67 Terminal type PCB, solder terminals Weight V23054 Size I approx. 20g V23054 Size II approx. 25g V23054Size III approx. 27g V23062 Size I approx. 30g V23062 Size II approx. 35g Washing not recommended Ultrasonic cleaning not recommended Packaging unit 5 pcs. Accessories For details see datasheet Cradle Relay, Accessories and Mounting Terminals: coil with 1 winding: start 4, end 1 coil with 2 windings (upon request): start 3, end 2 for winding I, start 4, end 1 for winding II The minimum voltage UI depends on the contact set and the ambient temperature, the maximum voltage UII only depends on the ambient temperature. Between minimum voltage UI tamb and operating voltage U a safety margin of approx. 20% is recommended. UI tamb (1.2) < UI ≤ UII tamb UI tamb UI · U20 °C · kI tamb UII tamb U Il 20 °C · kII tamb tamb Ambient temperature U Operating voltage UI tamb Minimum voltage at ambient temperature, tamb UII tamb Maximum voltage at ambient temperature, tamb kI and kII Factors
03-2012, Rev. 0312 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. AXICOM Signal Relays Cradle S Relay V23054/V23062 (Continued) Terminal assignment 2 form C (2 CO) V230xx-xxxxx-Bx04 V230xx-xxxxx-Cx04 Size I 2 form A (2 NO) V230xx-xxxxx-F105 6 form A (6 NO) V230xx-xxxxx-Bx12 V230xx-xxxxx-Cx12 Size II 4 form C (4 CO) V230xx-xxxxx-Bx10 V230xx-xxxxx-Cx10 2 form C (2 CO) V230xx-xxxxx-F104 Dimensions V23054-Cxxx, size I type V23054-Dxxx, size II type 6 form C (6 CO) V230xx-xxxxx-Bx33 V230xx-xxxxx-Cx33 Size III 4 form C (4 CO) V230xx-xxxxx-F110 V23054-Exxx, size I type
03-2012, Rev. 0312 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. AXICOM Signal Relays Cradle S Relay V23054/V23062 (Continued) V23062-Axxx, size I type V23062-Bxxx, size II type Dimensions Instructions for Impulse Operation The maximum voltage stated in the part code table can be increased for impulse operation as follows: U II Impuls UII tambxq UII tamb Maximum continuous voltage at ambient temperature tamb q Factor The impulse voltage must not exceed 80% of the test voltage (winding/ frame or winding/winding) or 2.5 times the value of the maximum voltage listed in the part code table. IftED ≤ 3s then q= ; IftED = Pulse width, t2 = Cycle time. If tED > 3s the value of q must be obtained from the nomograph. Examples of various periodic pulse trains (energizing side) 1. Periodic recurrence of one energizing pulse 2. Periodic recurrence of two unequal energizing pulses tED = tI + tII tI + tII = Pulse widths within one cycle
03-2012, Rev. 0312 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. AXICOM Signal Relays Cradle S Relay V23054/V23062 (Continued) Product code structure Typical product code V23054 -D 0 021 -B1 10 Type V23054 Cradle S Relay, dust protected V23062 Cradle S Relay, hermetically sealed Size V23054 types C Size I, dust-protected D Size II, dust-protected E Size III, dust-protected V23062 types A Size I, hermetically sealed B Size II, hermetically sealed Version
0 Standard version
1 Fitted with contact pile-ups F
2 For higher test voltage of 2kV coil/frame
3 Combination of 1 & 2 (contact pile-ups F and higher test voltage coil/frame)
Coil code: please refer to coil versions table Contact style B1 Single contacts B6 Single contacts F1 Single contacts C1 Bifurcated contacts C4 Bifurcated contacts Contact arrangement 04 2 form C, 2 CO 05 2 form A, 1 NO 10 4 form C, 4 CO 12 6 form A, 6 NO 33 6 form C, 6 CO Other types on request Product code Version Coil Operate/Lim. Arrangement Contacts Enclosure PartNumber V23054-CXXXX, standard, size I V23054-C0013-B104 Standard, size I 125VDC 59/190VDC 2 form C, 2 CO Single Dust protected 2-1419172-8 V23054-C0015-B104 Standard, size I 12VDC 4.7/18VDC 2 form C, 2 CO Single Dust protected 1393812-6 V23054-C0016-B104 Standard, size I 12.5VDC 5.4/21.5VDC 2 form C, 2 CO Single Dust protected 1393812-7 V23054-C0019-C104 Standard, size I 20VDC 10.5/31VDC 2 form C, 2 CO Bifurcated Dust protected 1422019-3 V23054-C2003-C404 Standard, size I 220VDC 98/240VDC 2 form C, 2 CO Bifurcated Dust protected 3-1393812-2 V23054-C2004-B104 Standard, size I 110VDC 44/145VDC 2 form C, 2 CO Single Dust protected 3-1393812-3 V23054-C2013-B104 Standard, size I 125VDC 59/190VDC 2 form C, 2 CO Single Dust protected 3-1393812-4 V23054-C2020-B104 Standard, size I 24VDC 10.5/39VDC 2 form C, 2 CO Single Dust protected 3-1393812-5 V23054-C2026-C104 Standard, size I 60VDC 36/94VDC 2 form C, 2 CO Bifurcated Dust protected 3-1393812-6 V23054-C0020-B104 Standard, size I 24VDC 10.5/39VDC 2 form C, 2 CO Single Dust protected 1-1393812-0 V23054-C0020-C104 Standard, size I 24VDC 13/39VDC 2 form C, 2 CO Bifurcated Dust protected 1-1393812-1 V23054-C0021-B104 Standard, size I 32VDC 14.5/50VDC 2 form C, 2 CO Single Dust protected 1-1393812-2 V23054-C0021-C104 Standard, size I 32VDC 17.5/50VDC 2 form C, 2 CO Bifurcated Dust protected 1-1393812-3 V23054-C0021-C404 Standard, size I 32VDC 17.5/50VDC 2 form C, 2 CO Bifurcated Dust protected 1-1393812-4 V23054-C0022-B104 Standard, size I 45VDC 19/66VDC 2 form C, 2 CO Single Dust protected 1-1393812-5 V23054-C0022-C104 Standard, size I 45VDC 24/66VDC 2 form C, 2 CO Bifurcated Dust protected 1-1393812-6 V23054-C0026-B104 Standard, size I 60VDC 29/94VDC 2 form C, 2 CO Single Dust protected 2-1393812-0 V23054-C0026-C104 Standard, size I 60VDC 36/94VDC 2 form C, 2 CO Bifurcated Dust protected 2-1393812-3 V23054-C0026-C404 Standard, size I 60VDC 36/94VDC 2 form C, 2 CO Bifurcated Dust protected 2-1393812-4 V23054-C003-B104 Standard, size I 220VDC 79/240VDC 2 form C, 2 CO Single Dust protected 1393812-2 V23054-C003-C104 Standard, size I 220VDC 98/240VDC 2 form C, 2 CO Bifurcated Dust protected 1393812-3 V23054-C004-B104 Standard, size I 110VDC 44/145VDC 2 form C, 2 CO Single Dust protected 1393812-4 V23054-C004-C104 Standard, size I 110VDC 53.5/145VDC 2 form C, 2 CO Bifurcated Dust protected 1393812-5 V23054-CXXXX, 5A, size I V23054-C1022-F105 5A, size I 45VDC 19/66VDC 2 form A, 2 NO Single Dust protected 3-1393812-1 V23054-C3015-F105 5A, size I 12VDC 4.7/18VDC 2 form A, 2 NO Single Dust protected 1422019-5
03-2012, Rev. 0312 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. AXICOM Signal Relays Cradle S Relay V23054/V23062 (Continued) Product code Version Coil Operate/Lim. Arrangement Contacts Enclosure PartNumber V23054-DXXXX, standard, size II V23054-D0013-B110 Standard, size II 125VDC 59/190VDC 4 form C, 4 CO Single Dust protected 4-1419172-5 V23054-D0015-B112 Standard, size II 12VDC 4.7/18VDC 6 form A, 6 NO Single Dust protected 6-1422019-5 V23054-D0016-C110 Standard, size II 12.5VDC 5.4/21.5VDC 4 form C, 4 CO Bifurcated Dust protected 4-1393812-2 V23054-D0017-B110 Standard, size II 16VDC 7/25.5VDC 4 form C, 4 CO Single Dust protected 4-1393812-3 V23054-D0017-B110 Standard, size II 16VDC 7/25.5VDC 4 form C, 4 CO Single Dust protected 4-1393812-4 V23054-D0019-B110 Standard, size II 20VDC 10.5/31VDC 4 form C, 4 CO Single Dust protected 4-1393812-6 V23054-D0019-C110 Standard, size II 20VDC 10.5/31VDC 4 form C, 4 CO Bifurcated Dust protected 4-1393812-7 V23054-D0019-C410 Standard, size II 20VDC 10.5/31VDC 4 form C, 4 CO Bifurcated Dust protected 5-1393812-0 V23054-D2003-B110 Standard, size II 220VDC 79/240VDC 4 form C, 4 CO Single Dust protected 1393813-1 V23054-D2013-B110 Standard, size II 125VDC 59/190VDC 4 form C, 4 CO Single Dust protected 1393813-2 V23054-D2020-B110 Standard, size II 24VDC 10.5/39VDC 4 form C, 4 CO Single Dust protected 1393813-3 V23054-D2021-B110 Standard, size II 32VDC 14.5/50VDC 4 form C, 4 CO Single Dust protected 1393813-4 V23054-D2021-B112 Standard, size II 32VDC 14.5/50VDC 6 form A, 6 NO Single Dust protected 1393813-5 V23054-D2026-B110 Standard, size II 60VDC 29/94VDC 4 form C, 4 CO Single Dust protected 1393813-6 V23054-D2026-B112 Standard, size II 60VDC 29/94VDC 6 form A, 6 NO Single Dust protected 1393813-7 V23054-D0020-B110 Standard, size II 24VDC 10.5/39VDC 4 form C, 4 CO Single Dust protected 5-1393812-1 V23054-D0020-B112 Standard, size II 24VDC 10.5/39VDC 6 form A, 6 NO Single Dust protected 5-1393812-2 V23054-D0020-C110 Standard, size II 24VDC 13/39VDC 4 form C, 4 CO Bifurcated Dust protected 5-1393812-3 V23054-D0002-C410 Standard, size II 1,2VDC 0,75/2,1VDC 4 form C, 4 CO Bifurcated Dust protected 3-1419137-7 V23054-D0021-B110 Standard, size II 32VDC 14.5/50VDC 4 form C, 4 CO Single Dust protected 5-1393812-4 V23054-D0021-C112 Standard, size II 32VDC 17.5/50VDC 6 form A, 6 NO Bifurcated Dust protected 5-1393812-5 V23054-D0022-B110 Standard, size II 45VDC 19/66VDC 4 form C, 4 CO Single Dust protected 5-1393812-8 V23054-D0022-C110 Standard, size II 45VDC 24/66VDC 4 form C, 4 CO Bifurcated Dust protected 5-1393812-9 V23054-D0002-B110 Standard, size II 1,2VDC 0,54/2,1VDC 4 form C, 4 CO Single Dust protected 6-1393812-2 V23054-D0026-B112 Standard, size II 60VDC 29/94VDC 6 form A, 6 NO Single Dust protected 6-1393812-3 V23054-D0026-C110 Standard, size II 60VDC 43/94VDC 4 form C, 4 CO Bifurcated Dust protected 6-1393812-4 V23054-D0026-C112 Standard, size II 60VDC 36/94VDC 6 form A, 6 NO Bifurcated Dust protected 6-1393812-5 V23054-D0026-C114 Standard, size II 60VDC 29/94VDC 4 form A, 4 NO Bifurcated Dust protected 6-1393812-6 V23054-D003-B110 Standard, size II 220VDC 79/240VDC 4 form C, 4 CO Single Dust protected 3-1393812-8 V23054-D004-C110 Standard, size II 110VDC 44/145VDC 4 form C, 4 CO Bifurcated Dust protected 3-1393812-9 V23054-DXXXX, 5A, size II V23054-D1003-F104 5A, size II 220VDC 98/240VDC 2 form C, 2 CO Single Dust protected 8-1393812-6 V23054-D1004-F104 5A, size II 110VDC 53.5/145VDC 2 form C, 2 CO Single Dust protected 8-1393812-7 V23054-D1011-F104 5A, size II 6VDC 2.9/9VDC 2 form C, 2 CO Single Dust protected 8-1393812-8 V23054-D1012-F104 5A, size II 8.4VDC 4.4/13VDC 2 form C, 2 CO Single Dust protected 8-1393812-9 V23054-D1015-F104 5A, size II 12VDC 5.8/18VDC 2 form C, 2 CO Single Dust protected 9-1393812-0 V23054-D1017-F104 5A, size II 16VDC 8.7/25.5VDC 2 form C, 2 CO Single Dust protected 9-1393812-1 V23054-D1019-F104 5A, size II 20VDC 10.5/31VDC 2 form C, 2 CO Single Dust protected 9-1393812-2 V23054-D1020-F104 5A, size II 24VDC 13/39VDC 2 form C, 2 CO Single Dust protected 9-1393812-3 V23054-D1021-F104 5A, size II 32VDC 17.5/50VDC 2 form C, 2 CO Single Dust protected 9-1393812-4 V23054-D1022-F104 5A, size II 45VDC 24/66VDC 2 form C, 2 CO Single Dust protected 9-1393812-5 V23054-D1026-F104 5A, size II 60VDC 36/94VDC 2 form C, 2 CO Single Dust protected 9-1393812-8 V23054-D3003-F104 5A, size II 220VDC 98/240VDC 2 form C, 2 CO Single Dust protected 1393813-9 V23054-D0300-F104 5A, size II 110VDC 53.5/145VDC 2 form C, 2 CO Single Dust protected 1-1393813-1 V23054-D3020-F104 5A, size II 24VDC 13/39VDC 2 form C, 2 CO Single Dust protected 1-1393813-4 V23054-D3026-F104 5A, size II 60VDC 36/94VDC 2 form C, 2 CO Single Dust protected 1-1393813-6 V23054-EXXXX, standard, size III V23054-E0012-B133 Standard, size III 8.4VDC 4.4/13VDC 6 form C, 6 CO Single Dust protected 2-1393813-5 V23054-E0015-B133 Standard, size III 12VDC 5.8/18VDC 6 form C, 6 CO Single Dust protected 2-1393813-6 V23054-E0015-C133 Standard, size III 12VDC 8.8/18VDC 6 form C, 6 CO Bifurcated Dust protected 2-1393813-7 V23054-E0016-B133 Standard, size III 12.5VDC 6.9/21.5VDC 6 form C, 6 CO Single Dust protected 2-1393813-8 V23054-E0016-C133 Standard, size III 12.5VDC 10/21.5VDC 6 form C, 6 CO Bifurcated Dust protected 3-1393813-0 V23054-E0017-B133 Standard, size III 16VDC 8.7/25.5VDC 6 form C, 6 CO Single Dust protected 3-1393813-1 V23054-E0017-C133 Standard, size III 16VDC 13/25.5VDC 6 form C, 6 CO Bifurcated Dust protected 3-1393813-2 V23054-E0019-B133 Standard, size III 20VDC 10.5/31VDC 6 form C, 6 CO Single Dust protected 3-1393813-3 V23054-E0019-C133 Standard, size III 20VDC 15.5/31VDC 6 form C, 6 CO Bifurcated Dust protected 3-1393813-4 V23054-E0019-C433 Standard, size III 20VDC 15.5/31VDC 6 form C, 6 CO Bifurcated Dust protected 3-1393813-5 V23054-E2004-B133 Standard, size III 110VDC 53.5/145VDC 6 form C, 6 CO Single Dust protected 9-1393813-0 V23054-E2013-B133 Standard, size III 125VDC 73/190VDC 6 form C, 6 CO Single Dust protected 1422019-2 V23054-E2026-B133 Standard, size III 60VDC 36/94VDC 6 form C, 6 CO Single Dust protected 9-1393813-4 V23054-E0020-B133 Standard, size III 24VDC 13/39VDC 6 form C, 6 CO Single Dust protected 3-1393813-6 V23054-E0020-B533 Standard, size III 24VDC 13/39VDC 6 form C, 6 CO Single Dust protected 3-1393813-9 V23054-E0020-B633 Standard, size III 24VDC 13/39VDC 6 form C, 6 CO Single Dust protected 4-1393813-0 V23054-E0020-C133 Standard, size III 24VDC 20/39VDC 6 form C, 6 CO Bifurcated Dust protected 4-1393813-1 V23054-E0020-C433 Standard, size III 24VDC 20/39VDC 6 form C, 6 CO Bifurcated Dust protected 4-1393813-2 V23054-E0021-B133 Standard, size III 32VDC 17.5/50VDC 6 form C, 6 CO Single Dust protected 4-1393813-3 V23054-E0022-B133 Standard, size III 45VDC 24/66VDC 6 form C, 6 CO Single Dust protected 4-1393813-4 V23054-E0022-B633 Standard, size III 45VDC 24/66VDC 6 form C, 6 CO Single Dust protected 4-1393813-5 V23054-E0022-C133 Standard, size III 45VDC 35/66VDC 6 form C, 6 CO Bifurcated Dust protected 4-1393813-6 V23054-E0026-B133 Standard, size III 60VDC 36/94VDC 6 form C, 6 CO Single Dust protected 4-1393813-8 V23054-E0026-C133 Standard, size III 60VDC 55/94VDC 6 form C, 6 CO Bifurcated Dust protected 4-1393813-9
03-2012, Rev. 0312 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. AXICOM Signal Relays Cradle S Relay V23054/V23062 (Continued) Product code Version Coil Operate/Lim. Arrangement Contacts Enclosure PartNumber V23054-EXXXX, 5A, size III V23054-E1003-F110 5A, size III 220VDC 118/240VDC 4 form C, 4 CO Single Dust protected 5-1393813-9 V23054-E1004-F110 5A, size III 110VDC 66/145VDC 4 form C, 4 CO Single Dust protected 6-1393813-0 V23054-E1011-F110 5A, size III 6VDC 3.5/9VDC 4 form C, 4 CO Single Dust protected 6-1393813-1 V23054-E1015-F110 5A, size III 12VDC 7/18VDC 4 form C, 4 CO Single Dust protected 6-1393813-3 V23054-E1016-F110 5A, size III 12.5VDC 8.1/21.5VDC 4 form C, 4 CO Single Dust protected 6-1393813-6 V23054-E1017-F110 5A, size III 16VDC 10.5/25.5VDC 4 form C, 4 CO Single Dust protected 6-1393813-8 V23054-E1019-F110 5A, size III 20VDC 13/31VDC 4 form C, 4 CO Single Dust protected 7-1393813-2 V23054-E1020-F110 5A, size III 24VDC 15.5/39VDC 4 form C, 4 CO Single Dust protected 7-1393813-6 V23054-E1021-F110 5A, size III 32VDC 21/50VDC 4 form C, 4 CO Single Dust protected 8-1393813-1 V23054-E1022-F110 5A, size III 45VDC 29/66VDC 4 form C, 4 CO Single Dust protected 8-1393813-2 V23054-E1026-F110 5A, size III 60VDC 43/94VDC 4 form C, 4 CO Single Dust protected 8-1393813-5 V23054-E3020-F110 5A, size III 24VDC 15.5/39VDC 4 form C, 4 CO Single Dust protected 1-1393814-0 V23062-AXXXX, standard, size I V23062-A0014-C404 Standard, size I 76VDC 32/110VDC 2 form C, 2 CO Bifurcated Herm. sealed 1393815-1 V23062-A0025-C104 Standard, size I 28VDC 15/40VDC 2 form C, 2 CO Bifurcated Herm. sealed 1393815-2 V23062-A0046-C104 Standard, size I 29VDC 13/43VDC 2 form C, 2 CO Bifurcated Herm. sealed 1393815-3 V23062-BXXXX, standard, size II V23062-B0019-C410 Standard, size II 20VDC 13/31VDC 4 form C, 4 CO Bifurcated Herm. sealed 1393815-4 V23062-B0020-C110 Standard, size II 24VDC 15.5/39VDC 4 form C, 4 CO Bifurcated Herm. sealed 1393815-5 V23062-B0022-C110 Standard, size II 45VDC 29/66VDC 4 form C, 4 CO Bifurcated Herm. sealed 1393815-7 V23062-B0026-B610 Standard, size II 60VDC 29/94VDC 4 form C, 4 CO Single Herm. sealed 1393815-8 V23062-BXXXX, 5A, size II V23062-B1004-F104 5A, size II 110VDC 53.5/145VDC 2 form C, 2 CO Single Herm. sealed 1-1393815-1 V23062-B1026-F104 5A, size II 60VDC 36/94VDC 2 form C, 2 CO Single Herm. sealed 1-1393815-7