V23026 TEC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 5
Technical content
03-2016, Rev. 0316 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. AXICOM Signal Relays P1 Relay V23026 Coil Data Magnetic system polarized Coil voltage range 3 to 24VDC other coil voltages on request Operative range, IEC 61810 see coil operative range Max. coil temperature 85°C Thermal resistance <130K/W Coil versions, THT, monostable Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDCmin. VDC min. Ω ±10% mW 006 3 2.25 0.3 137 66 001 5 3.75 0.5 370 68 005 9 6.75 0.9 1165 70 002 12 9.00 1.2 2250 34 004 24 18.00 2.4 4500 128 All figures are given for coil without pre-energization, at ambient temperature +23°C. Coil versions, SMT, monostable Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDCmin. VDC min. Ω ±10% mW 026 3 2.25 0.3 113 80 021 5 3.75 0.5 313 80 025 9 6.75 0.9 1015 80 022 12 9.00 1.2 1800 80 024 24 18.00 2.4 4500 128 All figures are given for coil without pre-energization, at ambient temperature +23°C. Coil operative range, monostable DC coil n Directly triggerable with TTL standard modules as ALS, HCT & ACT n Slim line 13.5x7.85mm (0.531x0.309”) n Switching current 1 A n Bifurcated 1 form C (CO) contact n Immersion cleanable n High sensitivity results in low nominal power consumption, 65 to 130mW for monostable and 30 to 150mW for bistable (latching) n Initial surge withstand voltage 2.5kV (2/10μs) meets the Bellcore Requirement GR-1089 1.5kV (10/160μs) meets FCC Part 68 Typical applications Automotive equipment, CAN bus, imobilizer, office equipment, measurement and control equipment, medical equipment, safety equipment Approvals UL 508 File No. E 111441 Technical data of approved types on request Contact Data Contact arrangement 1 form C (CO) Max. switching voltage 125VDC, 150VAC Rated current 1A Limiting continuous current, 85°C 1A Breaking capacity max. see max. DC load breaking capacity Contact material Palladium nickel, gold-rhodium covered Contact style bifurcated contact Min. recommended contact load 10mA at 20mV Initial contact resistance ≤50mΩ at 10mA/20mV Frequency of operation without load 200 ops./s Operate/release time max. 2ms Set/reset time max. 2ms Bounce time max. 3ms Electrical endurance at 12V/10mA typ. 50x106 operations at 6V/100mA typ. 10x106 operations at 30V/1000mA typ. 10x103 operations Contact ratings UL contact ratings 30VDC/1A 65VDC/0.46A 150VAC/0.46A Mechanical endurance typ. 109 operations Max. DC load breaking capacity 108-98009 Rev. E All specifications subject to change. Consult Tyco Electronics for latest specifications. 7 of 12 Telecom-, Signal and RF Relays P1 V23026 Relay AXICOM Contact Data Number of contacts and type 1 changeover contact Contact assembly Bifurcated contact Contact material Palladium nickel, gold-rhodium covered Limiting continuous current at max. ambient temperature 1 A Maximum switching current 1 A Maximum swichting voltage 125 Vdc
150 Vac
Maximum switching capacity 30 W, 60 VA Thermoelectric potential < 100 µV Initial contact resistance / measuring condition: 10 mA / 20 mV < 50 m□ Electrical endurance at 12 V / 10 mA at 6 V / 100 mA at 30 V / 1000 mA typ. 5 x 107 operations typ. 1 x 107 operations typ. 1 x 104 operations Mechanical endurance typ. 109 operations UL contact ratings 30 Vdc / 1 A 65 Vdc / 0.46 A 150 Vac / 0.46 A Max. DC Load Breaking Capacity 108-98009 Rev. E All specifications subject to change. Consult Tyco Electronics for latest specifications. 5 of 12 Telecom-, Signal and RF Relays P1 V23026 Relay AXICOM Coil Operating Range Unom = Nominal coil voltage Umax. = Upper limit of the operative range of the coil voltage (limiting voltage) when coils are continously energized Uop. min. = Lower limit of the operative range of the coil voltage (reliable operate voltage) Urel. min. = Lower limit of the operative range of the coil voltage (reliable release voltage) Umax. at 0 A Umax. at - 1 A Unom. nominal coil voltage Uop. min. Urel. min. Ambient Temperature [°C] Coil Voltage [U/Unom] Umax. at 0 A 65 mW 130 mW Ambient Temperature [°C] Coil Voltage [U/Unom] Unom. nominal coil voltage Umax. - 100 % coil duty at 0 A 65 mW Latching 32 mW LatchingUmax. - 5 % coil duty at 1 A Umax. - 5 % coil duty at 0 A Uset min. Z P1_THTSMD
03-2016, Rev. 0316 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. AXICOM Signal Relays P1 Relay V23026 (Continued) Insulation Data Initial dielectric strength between open contacts 500Vrms between contact and coil 1500Vrms Initial surge withstand voltage between contact and coil 2500V Capacitance between open contacts max. 5pF between contact and coil max. 6pF Clearance/creepage between contact and coil 0.75mm between adjacent contacts 0.75mm RF Data Isolation at 100MHz/900MHz -30.0dB/-18.0dB Insertion loss at 100MHz/900MHz -0.12dB/-1.9dB Voltage standing wave ratio (VSWR) at 100MHz/900MHz 1.06/1.75 Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at www.te.com/customersupport/rohssupportcenter Ambient temperature -40 to +85°C Category of environmental protection, IEC 61810 RT III - immersion cleanable Vibration resistance (functional) 20g, 200 to 2000Hz 40g, 10 to 200Hz Shock resistance (functional) IEC 60068-2-27 (half sine) 50 g Terminal type PCB terminals and SMT terminals Weight max. 2g Resistance to soldering heat THT IEC 60068-2-20 265 °C/10s Resistance to soldering heat SMT IEC 60068-2-58 see reflow profile Moisture sensitive level, JEDEC J-Std-020D MSL3 Washing not recommended Ultrasonic cleaning possible Packaging unit THT 2000 pcs. SMT 2400 pcs. Coil data (continued) Coil versions, THT and SMT, bistable 2 coils Coil Rated Set Reset Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ω ±10% mW 106 3 2.25 2.25 130 69 101 5 3.75 3.75 390 64 105 9 6.75 6.75 1200 68 102 12 9.00 9.00 1500 96 241) All figures are given for coil without pre-energization, at ambient temperature +23°C. Coils I and II are identical. 1) A nominal voltage of 24VDC is feasible with a 12VDC coil with a series resistor (1500Ω) Coil data (continued) Coil versions, THT, bistable 1 coil Coil Rated Set Reset Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ω ±10% mW 056 3 2.25 -2.25 300 30 051 5 3.75 -3.75 740 34 057 9 6.75 -6.75 2160 38 052 12 9.00 -9.00 4500 32 054 24 18.00 -18.00 4500 128 Coil data (continued) Coil versions, SMT, bistable 1 coil Coil Rated Set Reset Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ω ±10% mW 051 5 3.75 -3.75 740 34 052 12 9.00 -9.00 4500 32 A nominal voltage of 24V is feasible with a 12V coil with a series resitor (4500Ω) Other coil voltages on request All figures are given for coil without pre-energization, at ambient temperature +23°C. Coils I and II are identical. Coil operative range, bistable Umax upper limit of the operative range of the coil voltage (limiting voltage) when coils are continuously energized. Uop min lower limit of the operative range of the coil voltage (reliable operate voltage). Urel min lower limit of the operative range of the coil voltage (reliable release voltage). 108-98009 Rev. E All specifications subject to change. Consult Tyco Electronics for latest specifications. 5 of 12 Telecom-, Signal and RF Relays P1 V23026 Relay AXICOM Coil Operating Range Unom = Nominal coil voltage Umax. = Upper limit of the operative range of the coil voltage (limiting voltage) when coils are continously energized Uop. min. = Lower limit of the operative range of the coil voltage (reliable operate voltage) Urel. min. = Lower limit of the operative range of the coil voltage (reliable release voltage) Umax. at 0 A Umax. at - 1 A Unom. nominal coil voltage Uop. min. Urel. min. Ambient Temperature [°C] Coil Voltage [U/Unom] Umax. at 0 A 65 mW 130 mW Ambient Temperature [°C] Coil Voltage [U/Unom] Unom. nominal coil voltage Umax. - 100 % coil duty at 0 A 65 mW Latching 32 mW LatchingUmax. - 5 % coil duty at 1 A Umax. - 5 % coil duty at 0 A Uset min.
03-2016, Rev. 0316 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. AXICOM THT version 108-98009 Rev. E All specifications subject to change. Consult Tyco Electronics for latest specifications. 4 of 12 Telecom-, Signal and RF Relays P1 V23026 Relay AXICOM Dimensions Dimensions in mm THT Version Mounting hole layout View onto the component side of the PCB (top view) Terminal assignment Relay – top view Contact release or reset condition, coil polarity to set the relay Non-latching type not energized condition Latching type, 1 coil reset condition Latching type, 2 coils reset condition Contacts are shown in reset condition. Both coils can be used either as set or reset coil. THT V23026-x1xxx-B201 SMT V23026-x1xxx-B201 mm inch mm inch L W H 13.00 ± 0.10 7.60 ± 0.10 6.90 – 0.20 0.512 ± 0.004 0.299 ± 0.004 0.272 – 0.008 13.40 ± 0.10 7.75 ± 0.10 8.00 – 0.20 0.528 ± 0.004 0.305 ± 0.004 0.315 – 0.008 T S 3.50 – 0.20 N/A 5.08 ± 0.15 0.30 ± 0.10 N/A N/A 0.138 – 0.008 N/A 0.200 ± 0.006 0.012 ± 0.004 N/A N/A N/A 10.90 – 0.50 5.08 ± 0.15 N/A 0.85 ± 0.10 0.20 – 0.15 N/A 0.429 – 0.020 0.200 ± 0.006 N/A 0.033 ± 0.004 0.008 – 0.006 SMT Version Solder pad layout View onto the component side of the PCB (top view) 13.0±0.1 7.60±0.1 5.08±0.15 0.3±0.1 6.9-0.23.5-0.2 0.85±0.1 0.2-0.15 13.4±0.1 7.75±0.1 10.9-0.5 5.08±0.15 8.0-0.2 5.08 5.08 PCB layout TOP view on component side of PCB Dimensions 108-98009 Rev. E All specifications subject to change. Consult Tyco Electronics for latest specifications. 4 of 12 Telecom-, Signal and RF Relays P1 V23026 Relay AXICOM Dimensions Dimensions in mm THT Version Mounting hole layout View onto the component side of the PCB (top view) Terminal assignment Relay – top view Contact release or reset condition, coil polarity to set the relay Non-latching type not energized condition Latching type, 1 coil reset condition Latching type, 2 coils reset condition Contacts are shown in reset condition. Both coils can be used either as set or reset coil. THT V23026-x1xxx-B201 SMT V23026-x1xxx-B201 mm inch mm inch L W H 13.00 ± 0.10 7.60 ± 0.10 6.90 – 0.20 0.512 ± 0.004 0.299 ± 0.004 0.272 – 0.008 13.40 ± 0.10 7.75 ± 0.10 8.00 – 0.20 0.528 ± 0.004 0.305 ± 0.004 0.315 – 0.008 T S 3.50 – 0.20 N/A 5.08 ± 0.15 0.30 ± 0.10 N/A N/A 0.138 – 0.008 N/A 0.200 ± 0.006 0.012 ± 0.004 N/A N/A N/A 10.90 – 0.50 5.08 ± 0.15 N/A 0.85 ± 0.10 0.20 – 0.15 N/A 0.429 – 0.020 0.200 ± 0.006 N/A 0.033 ± 0.004 0.008 – 0.006 SMT Version Solder pad layout View onto the component side of the PCB (top view) 13.0±0.1 7.60±0.1 5.08±0.15 0.3±0.1 6.9-0.23.5-0.2 0.85±0.1 0.2-0.15 13.4±0.1 7.75±0.1 10.9-0.5 5.08±0.15 8.0-0.2 5.08 5.08 SMT version 108-98009 Rev. E All specifications subject to change. Consult Tyco Electronics for latest specifications. 4 of 12 Telecom-, Signal and RF Relays P1 V23026 Relay AXICOM Dimensions Dimensions in mm THT Version Mounting hole layout View onto the component side of the PCB (top view) Terminal assignment Relay – top view Contact release or reset condition, coil polarity to set the relay Non-latching type not energized condition Latching type, 1 coil reset condition Latching type, 2 coils reset condition Contacts are shown in reset condition. Both coils can be used either as set or reset coil. THT V23026-x1xxx-B201 SMT V23026-x1xxx-B201 mm inch mm inch L W H 13.00 ± 0.10 7.60 ± 0.10 6.90 – 0.20 0.512 ± 0.004 0.299 ± 0.004 0.272 – 0.008 13.40 ± 0.10 7.75 ± 0.10 8.00 – 0.20 0.528 ± 0.004 0.305 ± 0.004 0.315 – 0.008 T S 3.50 – 0.20 N/A 5.08 ± 0.15 0.30 ± 0.10 N/A N/A 0.138 – 0.008 N/A 0.200 ± 0.006 0.012 ± 0.004 N/A N/A N/A 10.90 – 0.50 5.08 ± 0.15 N/A 0.85 ± 0.10 0.20 – 0.15 N/A 0.429 – 0.020 0.200 ± 0.006 N/A 0.033 ± 0.004 0.008 – 0.006 SMT Version Solder pad layout View onto the component side of the PCB (top view) 13.0±0.1 7.60±0.1 5.08±0.15 0.3±0.1 6.9-0.23.5-0.2 0.85±0.1 0.2-0.15 13.4±0.1 7.75±0.1 10.9-0.5 5.08±0.15 8.0-0.2 5.08 5.08 THT version SMT version Monostable version rest condition 108-98009 Rev. E All specifications subject to change. Consult Tyco Electronics for latest specifications. 4 of 12 Telecom-, Signal and RF Relays P1 V23026 Relay AXICOM Dimensions Dimensions in mm THT Version Mounting hole layout View onto the component side of the PCB (top view) Terminal assignment Relay – top view Contact release or reset condition, coil polarity to set the relay Non-latching type not energized condition Latching type, 1 coil reset condition Latching type, 2 coils reset condition Contacts are shown in reset condition. Both coils can be used either as set or reset coil. THT V23026-x1xxx-B201 SMT V23026-x1xxx-B201 mm inch mm inch L W H 13.00 ± 0.10 7.60 ± 0.10 6.90 – 0.20 0.512 ± 0.004 0.299 ± 0.004 0.272 – 0.008 13.40 ± 0.10 7.75 ± 0.10 8.00 – 0.20 0.528 ± 0.004 0.305 ± 0.004 0.315 – 0.008 T S 3.50 – 0.20 N/A 5.08 ± 0.15 0.30 ± 0.10 N/A N/A 0.138 – 0.008 N/A 0.200 ± 0.006 0.012 ± 0.004 N/A N/A N/A 10.90 – 0.50 5.08 ± 0.15 N/A 0.85 ± 0.10 0.20 – 0.15 N/A 0.429 – 0.020 0.200 ± 0.006 N/A 0.033 ± 0.004 0.008 – 0.006 SMT Version Solder pad layout View onto the component side of the PCB (top view) 13.0±0.1 7.60±0.1 5.08±0.15 0.3±0.1 6.9-0.23.5-0.2 0.85±0.1 0.2-0.15 13.4±0.1 7.75±0.1 10.9-0.5 5.08±0.15 8.0-0.2 5.08 5.08 Terminal assignment Bistable version, 1 coil reset condition 108-98009 Rev. E All specifications subject to change. Consult Tyco Electronics for latest specifications. 4 of 12 Telecom-, Signal and RF Relays P1 V23026 Relay AXICOM Dimensions Dimensions in mm THT Version Mounting hole layout View onto the component side of the PCB (top view) Terminal assignment Relay – top view Contact release or reset condition, coil polarity to set the relay Non-latching type not energized condition Latching type, 1 coil reset condition Latching type, 2 coils reset condition Contacts are shown in reset condition. Both coils can be used either as set or reset coil. THT V23026-x1xxx-B201 SMT V23026-x1xxx-B201 mm inch mm inch L W H 13.00 ± 0.10 7.60 ± 0.10 6.90 – 0.20 0.512 ± 0.004 0.299 ± 0.004 0.272 – 0.008 13.40 ± 0.10 7.75 ± 0.10 8.00 – 0.20 0.528 ± 0.004 0.305 ± 0.004 0.315 – 0.008 T S 3.50 – 0.20 N/A 5.08 ± 0.15 0.30 ± 0.10 N/A N/A 0.138 – 0.008 N/A 0.200 ± 0.006 0.012 ± 0.004 N/A N/A N/A 10.90 – 0.50 5.08 ± 0.15 N/A 0.85 ± 0.10 0.20 – 0.15 N/A 0.429 – 0.020 0.200 ± 0.006 N/A 0.033 ± 0.004 0.008 – 0.006 SMT Version Solder pad layout View onto the component side of the PCB (top view) 13.0±0.1 7.60±0.1 5.08±0.15 0.3±0.1 6.9-0.23.5-0.2 0.85±0.1 0.2-0.15 13.4±0.1 7.75±0.1 10.9-0.5 5.08±0.15 8.0-0.2 5.08 5.08 Bistable version, 2 coils reset condition 108-98009 Rev. E All specifications subject to change. Consult Tyco Electronics for latest specifications. 4 of 12 Telecom-, Signal and RF Relays P1 V23026 Relay AXICOM Dimensions Dimensions in mm THT Version Mounting hole layout View onto the component side of the PCB (top view) Terminal assignment Relay – top view Contact release or reset condition, coil polarity to set the relay Non-latching type not energized condition Latching type, 1 coil reset condition Latching type, 2 coils reset condition Contacts are shown in reset condition. Both coils can be used either as set or reset coil. THT V23026-x1xxx-B201 SMT V23026-x1xxx-B201 mm inch mm inch L W H 13.00 ± 0.10 7.60 ± 0.10 6.90 – 0.20 0.512 ± 0.004 0.299 ± 0.004 0.272 – 0.008 13.40 ± 0.10 7.75 ± 0.10 8.00 – 0.20 0.528 ± 0.004 0.305 ± 0.004 0.315 – 0.008 T S 3.50 – 0.20 N/A 5.08 ± 0.15 0.30 ± 0.10 N/A N/A 0.138 – 0.008 N/A 0.200 ± 0.006 0.012 ± 0.004 N/A N/A N/A 10.90 – 0.50 5.08 ± 0.15 N/A 0.85 ± 0.10 0.20 – 0.15 N/A 0.429 – 0.020 0.200 ± 0.006 N/A 0.033 ± 0.004 0.008 – 0.006 SMT Version Solder pad layout View onto the component side of the PCB (top view) 13.0±0.1 7.60±0.1 5.08±0.15 0.3±0.1 6.9-0.23.5-0.2 0.85±0.1 0.2-0.15 13.4±0.1 7.75±0.1 10.9-0.5 5.08±0.15 8.0-0.2 5.08 5.08 Contacts are shown in reset condition. Both coils can be used either as set or reset coil. Contact position might change during transportation and must be reset before use. Signal Relays P1 Relay V23026 (Continued)
03-2016, Rev. 0316 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. AXICOM Signal Relays P1 Relay V23026 (Continued) Recommended soldering conditions Processing 108-98009 Rev. E All specifications subject to change. Consult Tyco Electronics for latest specifications. 9 of 12 Telecom-, Signal and RF Relays P1 V23026 Relay AXICOM Soldering conditions according IEC 60058-2-58 and IPC/JEDEC J-STD-020B Infrared Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature) Infrared Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature) Recommended Soldering Conditions Resistance to soldering heat - Re/f_lo w pro/f_ile Recommended re/f_lo w soldering pro/f_ile Vapor Phase Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature) 240 °C 180 °C 130 °C 100 °C 20 - 40 sec Full line: typical Dotted line: process limits forced cooling Temperature °CTemperature °C Time (s) Temperature °C Time (s) 108-98009 Rev. E All specifications subject to change. Consult Tyco Electronics for latest specifications. 9 of 12 Telecom-, Signal and RF Relays P1 V23026 Relay AXICOM Soldering conditions according IEC 60058-2-58 and IPC/JEDEC J-STD-020B Infrared Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature) Infrared Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature) Recommended Soldering Conditions Resistance to soldering heat - Re/f_lo w pro/f_ile Recommended re/f_lo w soldering pro/f_ile Vapor Phase Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature) 240 °C 180 °C 130 °C 100 °C 20 - 40 sec Full line: typical Dotted line: process limits forced cooling Temperature °CTemperature °C Time (s) Temperature °C Time (s) 108-98009 Rev. E All specifications subject to change. Consult Tyco Electronics for latest specifications. 9 of 12 Telecom-, Signal and RF Relays P1 V23026 Relay AXICOM Soldering conditions according IEC 60058-2-58 and IPC/JEDEC J-STD-020B Infrared Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature) Infrared Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature) Recommended Soldering Conditions Resistance to soldering heat - Re/f_lo w pro/f_ile Recommended re/f_lo w soldering pro/f_ile Vapor Phase Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature) 240 °C 180 °C 130 °C 100 °C 20 - 40 sec Full line: typical Dotted line: process limits forced cooling Temperature °CTemperature °C Time (s) Temperature °C Time (s) Soldering conditions according IEC 60058-2-58 and IPC/JEDEC J-STD-020B Resistance to soldering heat - Reflow profile Recommended reflow soldering profile Vapor Phase Soldering: temperature/time profile (lead and housing peak temperature) Infrared Soldering: temperature/ time profile (lead and housing peak temperature) Packing 108-98009 Rev. E All specifications subject to change. Consult Tyco Electronics for latest specifications. 10 of 12 Telecom-, Signal and RF Relays P1 V23026 Relay AXICOM Packing Dimensions in mm 11.6±0.2 13.8±0.2 Tube for THT version 40 relays per tube 2‘000 relays per box Tape and reel for SMT version 480 relays per reel 2‘400 per box Reel dimension Tube for THT version 40 relays per tube, 2000 relays per box 108-98009 Rev. E All specifications subject to change. Consult Tyco Electronics for latest specifications. 10 of 12 Telecom-, Signal and RF Relays P1 V23026 Relay AXICOM Packing Dimensions in mm 11.6±0.2 13.8±0.2 Tube for THT version 40 relays per tube 2‘000 relays per box Tape and reel for SMT version 480 relays per reel 2‘400 per box Reel dimension Tape and reel for SMT version 480 relays per reel, 2400 relays per box Reel dimensions 108-98009 Rev. E All specifications subject to change. Consult Tyco Electronics for latest specifications. 10 of 12 Telecom-, Signal and RF Relays P1 V23026 Relay AXICOM Packing Dimensions in mm 11.6±0.2 13.8±0.2 Tube for THT version 40 relays per tube 2‘000 relays per box Tape and reel for SMT version 480 relays per reel 2‘400 per box Reel dimension 108-98009 Rev. E All specifications subject to change. Consult Tyco Electronics for latest specifications. 10 of 12 Telecom-, Signal and RF Relays P1 V23026 Relay AXICOM Packing Dimensions in mm 11.6±0.2 13.8±0.2 Tube for THT version 40 relays per tube 2‘000 relays per box Tape and reel for SMT version 480 relays per reel 2‘400 per box Reel dimension
03-2016, Rev. 0316 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. AXICOM Signal Relays P1 Relay V23026 (Continued) Product code structure Typical product code V23026 A1 002 B201 Type V23026 P1 Series Signal Relay Version A1 THT, monostable D1 SMT, monostable B1 THT, bistable (latching), 2 coils E1 SMT, bistable (latching), 2 coils C1 THT, bistable (latching), 1 coil F1 SMT, bistable (latching), 1 coil Coil Coil code: please refer to coil versions table Contacts B201 1 form C, 1 CO Product Code Version Coil Coil voltage Part Number V23026A1006B201 THT version monostable 3VDC 1-1393774-7 V23026A1001B201 5VDC 1393774-1 V23026A1005B201 9VDC 1-1393774-5 V23026A1002B201 12VDC 1393774-8 V23026A1004B201 24VDC 1-1393774-2 V23026B1106B201 bistable, 2 coils 3VDC 1393775-3 V23026B1101B201 5VDC 3-1393774-4 V23026B1105B201 9VDC 1393775-2 V23026B1102B201 12VDC 3-1393774-5 V23026C1056B201 3VDC 2-1393774-6 V23026C1051B201 5VDC 2-1393774-0 V23026C1057B201 9VDC 2-1393774-7 V23026C1052B201 12VDC 2-1393774-1 V23026C1054B201 24VDC 2-1393774-4 V23026D1026B201 SMT version monostable 3VDC 1393776-8 V23026D1021B201 5VDC 1393776-3 V23026D1025B201 9VDC 1422015-9 V23026D1022B201 12VDC 1393776-4 V23026D1024B201 24VDC 1393776-7 V23026E1106B201 bistable, 2 coils 3VDC 1393777-3 V23026E1101B201 5VDC 1422015-6 V23026E1105B201 9VDC 1393777-2 V23026E1102B201 12VDC 1393776-9 V23026F1051B201 9VDC 1422015-8 V23026F1052B201 12VDC 4-1393774-3