1360A BELDEN | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

Part Number: 1360A Fieldbus, 1 Pr #16 Str TC, PO Ins, OS, PVC Jkt, CMG Product Description Fieldbus, 1 Pair 16AWG (7x24H) Tinned Copper, PO Insulation, Overall Beldfoil® Shield, Orange PVC Outer Jacket, CMG Technical Specifications Physical Characteristics (Overall) Conductor AWG Stranding Material No. of Pairs 16 7x24 TC - Tinned Copper 1 Conductor Count: 2 Insulation Material Nominal Wall Thickness PO - Polyolefin 0.029 in Color Chart Number Color

1 Blue and Orange

Type Material Material Trade Name Coverage [%] Drainwire Material Drainwire AWG Drainwire Construction n x D Tape Aluminum/Polyester Beldfoil® 100 % TC - Tinned Copper 20 7x28 mm Outer Jacket Material Material Nominal Diameter Nominal Wall Thickness PVC - Polyvinyl Chloride 0.4 in 0.065 in 0.4 in Construction and Dimensions Cabling Twists Filler 4.8 twist/ft Polypropylene

Electrical Characteristics

Nominal Conductor DCR Nominal Outer Shield DCR 4.2 Ohm/1000ft 7.5 Ohm/1000ft Capacitance Max. Capacitance Unbalance Nom. Capacitance Conductor to Shield Nom.Mutual Capacitance 1.2 pF/ft 45 pF/ft 24 pF/ft Inductance Nominal Inductance 0.19 µH/ft

Nominal Characteristic Impedance

100 Ohm

High Frequency (Nominal/Typical) Frequency [MHz] Nom. Insertion Loss 0.039 MHz 0.08 dB/100ft Delay Nominal Velocity of Propagation (VP) [%] 66 % High Freq Frequency [MHz] Max. Insertion Loss (Attenuation) Max./Min. Input Impedance (unFitted) 0.031 MHz 0.091 dB/100ft 100 Ohm Current Element Max. Recommended Current [A] Per Conductor 8 Amps per Conductor Voltage UL Voltage Rating

300 V RMS

Electrical Characteristics Notes: Max Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft Other Electrical Characteristic 2: 31.25 KBits/sec Temperature Range UL Temp Rating: 105°C Operating Temp Range: -40°C To +105°C Mechanical Characteristics Oil Resistance: Yes Bulk Cable Weight: 65 lbs/1000ft Max Recommended Pulling Tension: 71 lbs Min Bend Radius/Minor Axis: 4 in Standards NEC Articles: 800 NEC/(UL) Specification: CMR, ITC-ER, PLTC-ER CEC/C(UL) Specification: CMG CPR Euroclass: Eca Applicable Environmental and Other Programs EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/11/EC (BFR): Yes EU Directive 2011/65/EU (ROHS II): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU: Yes EU Directive Compliance: EU Directive 2003/11/EC (BFR) EU CE Mark: Yes EU RoHS Compliance Date (yyyy-mm-dd): 2004-01-01 CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Suitability Suitability - Burial: Yes Suitability - Indoor: Yes Suitability - Oil Resistance: Yes Suitability - Outdoor: Yes Suitability - Sunlight Resistance: Yes

Flammability, LS0H, Toxicity Testing C(UL) Flammability: FT4 UL Flammability: UL1666 Riser ISO/IEC Flammability: IEC 60332-1-2 IEEE Flammability: 1202 UL voltage rating: 300 V RMS Plenum/Non-Plenum Plenum (Y/N): No Part Number Variants Item # Color UPC Length Footnote 1360A 0031000 Orange 612825112631 1,000 ft C Footnote: C - CRATE REEL PUT-UP. Product Notes Notes: Fieldbus: Orange jacket. Profibus PA: Intrinsically Safe Blue jacket. Jacket diameter tolerance: +/- .010 History Update and Revision: Revision Number: 0.336 Revision Date: 08-22-2019 © 2019 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.