Creation date September 14, 2021 4:29:01 AM CEST Catalogue status 10.09.2021 / We reserve the right to make technical changes. 1 VPU II 2 PV 600V DC Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Type II surge voltage arrester for use in photovoltaic applications
- Pluggable arrester
- Suitable for protecting DC systems
- High energy absorption with short response time
- Tested in accordance with EN 50539-11
- Suitable for use in accordance with IEC 60364-7-712 / EN 50539-12
- Coded voltage level
- Installation in distribution board
- Thermal protection function General ordering data Version Surge voltage arrester, Low voltage, without telecomm. contact Order No. 1351340000 Type VPU II 2 PV 600V DC GTIN (EAN) 4050118158731 Qty. 1 pc(s). Replacement parts 1351320000
VPU II 2 PV 600V DC Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Creation date September 14, 2021 4:29:01 AM CEST Catalogue status 10.09.2021 / We reserve the right to make technical changes. 2 Dimensions and weights Depth 69 mm Depth (inches) 2.717 inch Height 94 mm Height (inches) 3.701 inch Width 35.6 mm Width (inches) 1.402 inch Mounting dimension - height 75 mm Net weight 290 g Temperatures General data Colour black, orange Design Installation housing; 2TE, Insta IP 20 Operating altitude ≤ 2000 m Optical function display green = OK; red = arrester is defective - replace Protection degree IP20 Rail TS 35 UL 94 flammability rating V-0 Version without telecomm. contact Insulation coordination acc. to EN 50178 Pollution severity 2 Surge voltage category III Photovoltaic technical data Conditions and requirements EN 50539-11 Discharge current In (8/20 µs) 12.5 kA Discharge current, max. (8/20 µs) 40 kA Maximum continuous operating voltage UCPV mode +/-, -/PE, +/PE 600 V DC Operating height in the grounded PV system ≤ 2000 m Operating height in ungrounded PV system ≤ 2000 m PV system voltage, max. Ucpv 600 V Protection level Up (+/-) ≤ 4.4 kV Protection level Up (+/PE) ≤ 2.2 kV Protection level Up (-/PE) ≤ 2.2 kV Requirements class Type II Short-circuit curent ISCPV 200 A Standards EN 50539-11 Rated data IEC / EN Discharge current Imax (8/20µs) wire-PE 40 kA Discharge current In (8/20µs) wire-PE 20 kA Discharge current, max. (8/20 µs) 40 kA Leakage current at Un 30 µA Max. continuous voltage, Uc (DC) 600 V Number of poles 2 PV voltage, acc. to IEC 60364-7-712 < 600 V Rated voltage (DC) 600 V Response time ≤ 25 ns SPD type T2 Signalling contact No Standards EN 50539-11 Voltage type DC
VPU II 2 PV 600V DC Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Creation date September 14, 2021 4:29:01 AM CEST Catalogue status 10.09.2021 / We reserve the right to make technical changes. 3 Connection data Type of connection Screw connection Stripping length, rated connection 15 mm Tightening torque, min. 2 Nm Tightening torque, max. 3 Nm Clamping range, rated connection 16 mm² Clamping range, min. 1.5 mm² Clamping range, max. 35 mm² Wire cross-section, solid, min. 1.5 mm² Wire cross-section, solid, max. 16 mm² Wire connection cross section, finely stranded, min. 1.5 mm² Wire connection cross section, finely stranded, max. 25 mm² Conductor cross-section, flexible, AEH (DIN 46228-1), min. 1.5 mm² Conductor cross-section, flexible, AEH (DIN 46228-1), max. 50 mm² Connection cross-section, stranded, min. 1.5 mm² Connection cross-section, stranded, max. 50 mm² Classifications ETIM 6.0 EC000941 ETIM 7.0 EC000941 ETIM 8.0 EC000941 ECLASS 9.0 27-13-08-05 ECLASS 9.1 27-13-08-05 ECLASS 10.0 27-13-08-05 ECLASS 11.0 27-13-08-05 Tender specification sheets Long specification Multi-pole surge voltage arrestor according to the requirements of Class II acc. to IEC 50539-11. Consisting of V0 material, the arrestor serves as overvoltage protection and is used in applications according to IEC 50539-12. The use of a high-performance varistor meets the inspection requirements for Class II surge protection systems on the basis of the standards. The arrestor is installed in the vicinity of the equipment that needs protection, in a commercially available installation/electrical distribution enclosure. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window changes from green to red. Rated voltage: 600 VAC In/ max (8/20 µs): 20/40 kA, protection level < 2.2 kV l, type: Weidmüller VPU II 2 PV 600 V/40 kA, Order No. 1351340000 or equivalent Short specification Class II arrester with In/ Imax: 20/40 kA suitable for 600 V PV systems. Protection level < 2.2 kV. Type: Weidmüller VPU II
2 PV 600 V/40 kA Order
no. 13513400000 or equivalent
VPU II 2 PV 600V DC Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Creation date September 14, 2021 4:29:01 AM CEST Catalogue status 10.09.2021 / We reserve the right to make technical changes. 4 Approvals Approvals ROHS Conform Downloads Approval/Certificate/Document of Conformity EAC VPU SERIES EU_Konformitätserklärung / EU_Declaration_of_Conformity Engineering Data STEP Engineering Data EPLAN, WSCAD User Documentation Beipackzettel / Instruction sheet Catalogues Catalogues in PDF-format Brochures