SG13309 EATON | Alldatasheet
Document overview
- Manufacturer or author: E9600953
- PDF pages: 36
Technical content
Impulse Current Iimp (10/350)µs Type Designation Article No. Units per package Lightning current arresters SPI No decoupling necessary, if arrester class C with Uc = 460 V are used for combination 35kA L - (PE)N 50kA N - PE 100kA N - PE SPI-35/440 263137 6 / 120 SPI-50/NPE 263138 2 / 120 SPI-100/NPE 263139 1 / 60 SG13005 SPI-35/440 Lightning current arrester Sets, Lightning protection classes I, II, III, IV Description Type Designation Article No. Units per package SPD Class B, SPI TN-C-Set 3-pole TN-S/TT -Set 3+1-pole SPI-35/440/3 267487 1 / 40 SPI-3+1 267488 1 / 20 SG14605 SPI-3+1 SPD Class B+C Impulse Current Iimp (10/350)µs Type Designation Article No. Units per package Lightning current arrester - surge arrester SPBT12 12.5kA L - (PE) N 100 kA N-PE SPBT12-280/1 158306 12 / 120 SPBT12-NPE100 158307 1 / 60 Lightning current arrester - surge arrester Sets, Lightning protection classes III, IV Description Type Designation Article No. Units per package SPD Class B+C, SPBT12 Without remote indication TN-S/TT -Set 1+1-pole TN-S-Set 2-pole TN-C-Set 3-pole TN-S-Set 4-pole TN-S/TT -Set 3+1-pole TN-S/TT -Set 3+1-pole SPBT12-280-1+NPE 158308 1 / 40 SPBT12-280/2 158309 1 / 60 SPBT12-280/3 158330 1 / 40 SPBT12-280/4 158331 1 / 30 SPBT12-280-3+NPE 158332 1 / 20 SPBT12-280-3+NPE/BB 158333 1 Accessories Auxiliary switch for SPBT12-280 Busbar ASAUXSC-SPM 131785 4 / 120 ZV-KSBI... With remote indication TN-S/TT -Set 1+1-pole TN-S/TT -Set 3+1-pole SPBT12-280-1+NPE-AX 158334 1 / 30 SPBT12-280-3+NPE-AX 158335 1 SG29612 SG27112 SPBT12-280/1 Surge Protection SPBT12-280/3 SG10407 SPBT12-280-3+NPE-AX Lead-through terminal for SPI SPB-D-125 248145 2 / 120 PHASE OUT TYPE PHASE OUT TYPE
Lightning current arrester - surge arrester Sets, Lightning protection classes I, II, III, IV Description Type Designation Article No. Units per package SPD Class B+C, SP-B+C/ TN-C-Set 3-pole TN-S/TT -Set 3+1-pole SP-B+C/3 267489 1 SP-B+C/3+1 267510 1 SG14905 SP-B+C/3 Accessories Auxiliary switch for SP-B+C ASAUXSC-SPM 131785 8 / 80 Surge Protection
SPC-E-175 1 18920 12 / 120 SPC-E-280 248150 12 / 120 SPC-E-335 248151 12 / 120 SPC-E-385 248152 12 / 120 SPC-E-460 248153 12 / 120 SPC-E-580 248154 12 / 120 SPC-E-N/PE 248157 12 / 120 U1302 Plug-in surge arrester SPC-S Insert 1-pole Insert 75VAC 15kA Insert 130VAC 20kA Insert 175VAC 20kA Insert 280VAC 20kA Insert 335VAC 20kA Insert 385VAC 20kA Insert 460VAC 20kA Insert 580VAC 20kA Insert N-PE 260VAC 30kA SPC-S-15/75 248158 4 / 120 SPC-S-20/130 248159 4 / 120 SPC-S-20/175 248160 4 / 120 SPC-S-20/280 248161 4 / 120 SPC-S-20/335 248162 4 / 120 SPC-S-20/385 248163 4 / 120 SPC-S-20/460 248164 4 / 120 SPC-S-20/580 248165 4 / 120 SPC-S-N/PE 248166 4 / 120 SG13109 Plug-in surge arrester SPC-S, 1- to 4-pole Complete (2- and multi-pole surge arresters are supplied with busbar) U1202 1-pole 130VAC 1x20kA 1-pole 175VAC 1x20kA 2-pole 175VAC 2x20kA 1-pole 280VAC 1x20kA 2-pole 280VAC 2x20kA 3-pole 280VAC 3x20kA 4-pole 280VAC 4x20kA 1-pole 335VAC 1x20kA 2-pole 335VAC 2x20kA 3-pole 335VAC 3x20kA 4-pole 335VAC 4x20kA 1-pole 385VAC 1x20kA 2-pole 385VAC 2x20kA 3-pole 385VAC 3x20kA 4-pole 385VAC 4x20kA 1-pole 460VAC 1x20kA 2-pole 460VAC 2x20kA 3-pole 460VAC 3x20kA 4-pole 460VAC 4x20kA 1-pole 580VAC 1x20kA 1+1p – – 3+1p – – 3+1p – – SPC-S-20/130/1 248188 12 / 120 SPC-S-20/175/1 248189 12 / 120 SPC-S-20/175/2 248190 1 / 60 SPC-S-20/280/1 248172 12 / 120 SPC-S-20/280/2 248173 1 / 60 SPC-S-20/280/3 248174 1 / 40 SPC-S-20/280/4 248175 1 / 30 SPC-S-20/335/1 248176 12 / 120 SPC-S-20/335/2 248177 1 / 60 SPC-S-20/335/3 248178 1 / 40 SPC-S-20/335/4 248179 1 / 30 SPC-S-20/385/1 248180 12 / 120 SPC-S-20/385/2 248181 1 / 60 SPC-S-20/385/3 248182 1 / 40 SPC-S-20/385/4 248183 1 / 30 SPC-S-20/460/1 248184 12 / 120 SPC-S-20/460/2 248185 1 / 60 SPC-S-20/460/3 248186 1 / 40 SPC-S-20/460/4 248187 1 / 30 SPC-S-20/580/1 248191 12 / 120 SPC-S-1+1 248192 1 / 60 SPC-S-3+1 248193 1 / 30 SPC-S-3+N/PE 1 15795 1 / 30 Base 1- to 4-pole Base 1-pole Base 1+1 2-pole Base 2-pole Base 3-pole Base 4-pole Base 3+1 4-pole SPC-S-S1 248167 12 / 120 SPC-S-S2-1+1 248201 6 / 60 SPC-S-S2 248168 6 / 60 SPC-S-S3 248169 4 / 40 SPC-S-S4 248170 3 / 30 SPC-S-S4-3+1 248171 3 / 30 SG14802 SPC-S-20/280 SPC-S-S4-3+1 PHASE OUT TYPE PHASE OUT TYPE PHASE OUT TYPE
Plug-in surge arrester SPCT2 Insert 1-pole Insert 75VAC 20kA Insert 130VAC 20kA Insert 175VAC 20kA Insert 280VAC 20kA Insert 335VAC 20kA Insert 385VAC 20kA Insert 460VAC 20kA Insert 580VAC 20kA Insert 260VAC 30kA SPCT2-075 167577 4/120 SPCT2-130 167582 4/120 SPCT2-175 167587 4/120 SPCT2-280 167592 4/120 SPCT2-335 167597 4/120 SPCT2-385 167602 4/120 SPCT2-460 167607 4/120 SPCT2-580 167612 4/120 SPCT2-NPE60 167617 4/120 SG14902 Plug-in surge arrester SPCT2, 1- to 4-pole Complete (2- and multi-pole surge arresters are supplied with busbar) U1202 1-pole 75VAC 20kA 1-pole 130VAC 20kA 1-pole 175VAC 20kA 1-pole 280VAC 20kA 1-pole 335VAC 20kA 1-pole 385VAC 20kA 1-pole 460VAC 20kA 1-pole 580VAC 20kA 1+N 260VAC 30kA 2-pole 75VAC 2x20kA 2-pole 130VAC 2x20kA 2-pole 175VAC 2x20kA 2-pole 280VAC 2x20kA 2-pole 335VAC 2x20kA 2-pole 385VAC 2x20kA 2-pole 460VAC 2x20kA 2-pole 580VAC 2x20kA 3-pole 75VAC 3x20kA 3-pole 130VAC 3x20kA 3-pole 175VAC 3x20kA 3-pole 280VAC 3x20kA 3-pole 335VAC 3x20kA 3-pole 385VAC 3x20kA 3-pole 460VAC 3x20kA 3-pole 580VAC 3x20kA 4-pole 75VAC 4x20kA 4-pole 130VAC 4x20kA 4-pole 175VAC 4x20kA 4-pole 280VAC 4x20kA 4-pole 335VAC 4x20kA 4-pole 385VAC 4x20kA 4-pole 460VAC 4x20kA 4-pole 580VAC 4x20kA 1+N 280VAC 20kA 1+N 335VAC 20kA 1+N 385VAC 20kA 1+N 460VAC 20kA 1+N 580VAC 20kA 3+N 280VAC 20kA 3+N 335VAC 20kA 3+N 385VAC 20kA 3+N 460VAC 20kA 3+N 580VAC 20kA 3+N/BB 280VAC 3x20kA 3+N/BB 335VAC 3x20kA 3+N/BB 385VAC 3x20kA 3+N/BB 460VAC 3x20kA SPCT2-075/1 167578 12/120 SPCT2-130/1 167583 12/120 SPCT2-175/1 167588 12/120 SPCT2-280/1 167593 12/120 SPCT2-335/1 167598 12/120 SPCT2-385/1 167603 12/120 SPCT2-460/1 167608 12/120 SPCT2-580/1 167613 12/120 SPCT2-NPE60/1 167618 12/120 SPCT2-075/2 167579 1/60 SPCT2-130/2 167584 1/60 SPCT2-175/2 167589 1/60 SPCT2-280/2 167594 1/60 SPCT2-335/2 167599 1/60 SPCT2-385/2 167604 1/60 SPCT2-460/2 167609 1/60 SPCT2-580/2 167614 1/60 SPCT2-075/3 167580 1/40 SPCT2-130/3 167585 1/40 SPCT2-175/3 167590 1/40 SPCT2-280/3 167595 1/40 SPCT2-335/3 167600 1/40 SPCT2-385/3 167605 1/40 SPCT2-460/3 167610 1/40 SPCT2-580/3 167615 1/40 SPCT2-075/4 167581 1/30 SPCT2-130/4 167586 1/30 SPCT2-175/4 167591 1/30 SPCT2-280/4 167596 1/30 SPCT2-335/4 167601 1/30 SPCT2-385/4 167606 1/30 SPCT2-460/4 16761 1 1/30 SPCT2-580/4 167616 1/30 SPCT2-280-1+NPE 167619 1/60 SPCT2-335-1+NPE 167621 1/60 SPCT2-385-1+NPE 167623 1/60 SPCT2-460-1+NPE 167625 1/60 SPCT2-580-1+NPE 167627 1/60 SPCT2-280-3+NPE 167620 1/30 SPCT2-335-3+NPE 167622 1/30 SPCT2-385-3+NPE 167624 1/30 SPCT2-460-3+NPE 167626 1/30 SPCT2-580-3+NPE 167628 1/30 SPCT2-280-3+NPE/BB 167629 1 SPCT2-335-3+NPE/BB 167630 1 SPCT2-385-3+NPE/BB 167631 1 SPCT2-460-3+NPE/BB 167632 1 SPCT2-280 NEW NEW Surge Protection
Description Type Designation Article No. Units per package SPD Class C, SPC Surge arrester set SPC-S-3+1-SET 248194 1 SG14805 Auxiliary Switch for SPCT2 ASAUXSC-SPM 131785 8 / 80 SG60611 Surge Protection PHASE OUT TYPE SPC-S-3+1-SET NEW Description Type Designation Article No. Units per package Lead-through terminal for SPB, ASLTT -63 ASLTT -63 131784 12 / 120 SG59511
Photovoltaic - Surge Protection SPD-type T2 (Class C)
600 V DC
1000 V DC
SPPT2PA-600-2PE 132663 1 / 60 SPPT2PA-1000-2PE 132664 1 / 60 SPPT2PA-1000-2PE-AX 132666 1 / 60 For unearthed systems SPPT2PA-600-2+1PE 132661 1 / 40 SPPT2PA-1000-2+1PE 132662 1 / 40 SPPT2PA-1000-2+1PE-AX 132665 1 / 40 Plug-in Surge Arrester SPPT2PA for Photovoltaic application For earthed systems SG11309 SG11009
600 V DC À
1000 V DC À
110 0 V D C Á SPPT2PA-600 132667 1 SPPT2PA-1000 132668 1 SPPT2PA-1 100 132669 1 Inserts for replacement Earthed system Unearthed system SPPT2PA-600-2PE SPPT2PA-1000-2PE(-AX) SPPT2PA-600-2+1PE SPPT2PA-1000-2+1PE(-AX) L- L- L+ VOC ≤ Uc: Open circuit voltage of PV-Generator shall be equal or less than maximum continuous operating voltage of Surge Protective Device (SPD) to prevent its damage. Attention: Even at switched off DC-Disconnector system stays under high voltage! Before mounting ensure de-energizing and check zero-potential. DC
Poles Type Designation Article No. Units per package Busbars Z-GV-U/ for SPI, SP-B+C Z-GV-U/2 272588 20 / 1200 Z-GV-U/3 272589 20 / 1200 Z-GV-U/4 274080 20 / 1200 Z-GV-U/5 274081 20 / 1200 Z-GV-U/6 274082 20 / 400 Z-GV-U/8 274083 20 / 200 Z-GV-U/9 274084 20 / 200 Z-GV-U/9 Busbar Z-GV-16/3P-3TE/6 for SPI and SPC Z-GV-16/3P-3TE/6 26751 1 12 / 240 WA_SG11202 Busbars ZV-KSBI for SPC 2MU 3MU 3MU 2MU+1.5MU 4MU 5MU 5MU 2MU+3x1.5MU 6MU 7MU 7MU 7MU 9MU
11 M U
ZV-KSBI-2TE 263961 10 / 600 ZV-KSBI-3TE 263962 10 / 600 ZV-KSBI-3TE/S 263963 10 / 600 ZV-KSBI-3TE+HI 1 12370 50 / 150 ZV-KSBI-4TE 263964 10 / 600 ZV-KSBI-5TE 263965 10 / 200 ZV-KSBI-5TE/N 263966 10 / 200 ZV-KSBI-5TE+HI 1 12371 50 / 150 ZV-KSBI-6TE 1 131 18 50 / 500 ZV-KSBI-7TE 263967 50 / 500 ZV-KSBI-7TE/S 263968 10 / 100 ZV-KSBI-7TE/N 263969 10 / 100 ZV-KSBI-9TE/N 266874 50 / 500 ZV-KSBI-1 1TE 263970 50 / 500
Description Type Designation Article No. Units per package Surge protective device SPD-S-1+1 for TN-, TT -systems (3-phase 4-wire) Complete device Insert N-PE Insert L -N Base 1+1 2-pole Auxiliary switch SPD-S-1+1 248202 1 / 60 SPD-S-N/PE 248199 4 / 120 SPD-S-L/N 248200 4 / 120 SPC-S-S2-1+1 248201 6 / 60 SPC-S-HK 248203 8 / 80 U1602 Surge protective device SPD-S-280/2 for IT -, TT -systems (3-phase 3-wire) Complete device Insert Base Auxiliary switch SPD-S-280/2 269088 1 / 60 SPD-S-280 269087 4 / 120 SPC-S-S2 248168 6 / 60 SPC-S-HK 248203 8 / 80 SPD-S-1+1 Surge Protection SPD Class D PHASE OUT TYPE PHASE OUT TYPE 19” Multiple Outlet Strips NWS-STL/19/7F 7 outlets, DIN 7 outlets, plus switch, DIN 7 outlets, UTE NWS-STL/19/7F 255398 1 NWS-STL/19/7F/S/BL 255399 1 NWS-STL/19/7F/UTE 290031 1 N00411 19” Surge Protection - Multiple Outlet Strips with Switch SPD-STL/19/7F-S/BL 7 outlets, plus switch, DIN 7 outlets, UTE SPD-STL/19/7F-S/BL 283449 1 SPD-STL/19/7F-S/BL/UTE 290032 1 N00511 Surge Protection Multiple Outlet Strips with High-Range Filter and Energy Absorption for full Equipment Protection SPD-STL/6F-S 6 outlets, plus switch, DIN 6 outlets, plus switch, DIN+ISDN 19" fixing bracket for SPD-STL/6F-S (1U) SPD-STL/6F-S (68583) 13 0000 1 SPD-STL/6F-S/ISDN (68585) 147795 1 NWS-HW/19/SPD-STL/6F-S 166364 1 N04011
Earthing/Equipotential Bonding Description Type Designation Article No. Units per package Equipotential Bonding Bar PAS-7x16 7 x 2.5 - 16 mm2 PAS-7x16 107945 10 / 50 For main equipotential bonding Earthing strip up to 30 x 3.5 / Round conductor 7 - 10 mm SG07306 Earthing Bar for Antenna Lines PAS-HF-6 6 x HF-Cable shields PAS-HF-6 107946 10 / 100 Earthing conductor 6 - 25 mm 2 — — SG07206 Earth Clips EBS Tube Ø 1/8” - 1½” Tube Ø 1/8” - 4” EBS-210mm 107947 20 / 80 EBS-430mm 107948 20 / 80 For copper and galvanized steel/stainless steel tubes Cross-section for connection 1 x 2.5 mm 2 to 2 x 16 mm2 SG07406
SPD Class B, Lightning Current Arrester SPI Field of application: For the protection of low voltage distribution systems against direct lightning stroke into the overhead power supply line or exter- nal lightning protection system (IEC 62305). Application according to IEC 60364-5-53 Clause 534 Test class in accordance with IEC 61643-1 SPD-type in accordance with EN 61643-1 Capsuled version: during the discharge process, the device does not issue any hot ionised gases. Therefore, there is no need for keeping a safety dis- tance to flammable materials. Technical Data SPI-35/440 SPI-50/NPE SPI-100/NPE Electrical Design capsuled capsuled capsuled Responding time tr < 100 ns < 100 ns < 100 ns Voltage protection level Up 1.5 kV 1.5 kV 1.5 kV Maximum continuous operating voltage UC 440 VAC 260 VAC 260 VA Temporary overvoltage test value UT (200 ms) – 1200 VAC 1200 VAC (5 s) U T = UC –– Rated frequency 50/60 Hz 50/60 Hz 50/60 Hz Discharge current (8/20) µs Imax/In 35 kA 50 kA 100 kA Impulse current Iimp (10/350) µs Peak current 35 kA 50 kA 100 kA Charge Q 17 .5 As 25 As 50 As Specific energy 305 kJ/ Ω 625 kJ/Ω 2500 kJ/Ω Insulation resistance RISO >10 MΩ >10 MΩ >10 MΩ 1.5kAr.m.s/440V – – Short-circuit current strength at max. back-up fuse 25kA r.m.s –– Maximum back-up fuse 125 AgL – – Connection diagram Mechanical Frame size 45 mm 45 mm 45 mm Device height 90 mm 90 mm 90 mm Device width 17 .5 mm 17 .5 mm 35 mm Weight 174 g 178 g 320 g Upper and lower lift terminal capacity rigid 0.5 - 35 mm 2 0.5 - 35 mm2 10 - 50 mm2 flexible 0.5 - 25 mm 2 0.5 - 25 mm2 16 - 35 mm2 Tightening torque of terminal screws 4 - 4.5 Nm 4 - 4.5 Nm 6 - 8 Nm Mounting quick fastening on DIN rail IEC/EN 60715 Degree of protection acc. to IEC 60529 (installed) IP20 (IP40) Accessories: busbars Z-GV-U/ Permitted relative air humidity < 95% Permitted ambient temperature -40°C to +85°C Dimensions (mm) SPI-35/440, SPI-50/NPE I SPI-100/NPE Installation of lightning current arresters upstream of the meter is subject to co-ordination with the relevant power supply company. Installation of an r.m.s.ective protection cascade (SPD classes B, C, D) requires co-ordinated application of the respective protective devices. This is ensured by a defined line length between protective devices. When using lightning current arresters of type SPI in connection with surge arresters SPC with a maximum continuous operating voltage Uc of 460 V AC, no specific line length or decoupling coils are required. Practical Hint Application Example Attention! SPI-.../NPE should be used only as a N-PE spark gap in a e.g. TT -system (con- nection type 2 according to IEC 60364-5-
534 Clause 534)
SPI-50/NPE: for protection class III, IV according to IEC 62305 SPI-100/NPE: for protection class I, II, III, IV according to IEC 62305 Surge Protection SPI-35/440/3 SPI-3+1 Lightning current arrester Sets, Lightning protection classes I, II, III, IV . . .SPI-35/440 . . .SPI-100/NPE . . .SPB-D-125 . . . .Z-GV-U/3 . . .Z-GV-U/6
SPD Class B+C, Lightning Current Arrester - Surge Arresters SPBT12 Field of application For the protection of low voltage distribution systems against transient overvoltage caused by direct and indirect lightning stroke and switching operations. Application according to IEC 60364-5-53 Clause 534 Test class , in accordance with IEC 61643-1 SPD-type , in accordance with EN 61643-1 1 Lightning protection classes III and IV in accordance with IEC 62305 Busbars ZV-KSBI are available for all customary applications III Technical Data SPBT12-280... SPBT12-NPE100 Electrical per pole Responding time (rate of voltage rise 5 kV/µs) < 25 ns < 100 ns Voltage protection level Up < 1.5kV < 1.5kV Voltage protection level at 5 kA (8/20) µs 950 V – Maximum continuous operating voltage UC 280 VAC 255 VAC Temporary overvoltage test value UT 370 VAC (5 s) 1200 VAC (200 ms) Rated frequency 50/60 Hz 50/60 Hz Open circuit voltage Uoc 10 kV 20 kV Nominal discharge current (8/20) µs In 25 kA 100 kA Maximum discharge current Imax 50 kA 100 kA Imulse current Iimp (10/350) µs Peak current 12.5 kA 100 kA Charge Q 6.25 As 50 As Specific energy 39.1 kJ/ Ω 2500 kJ/Ω Follow current interrupt rating Ifi –1 0 0 A r.m.s Maximum back-up fuse 160 AgL/gG – Maximum short-circuit current 50 kA r.m.s – Connection diagram Mechanical Frame size 45 mm 45 mm Device height 80 mm 80 mm Device width 17 .5 mm 35 mm Weight 121 g 250 g Permitted ambient temperature -40°C to +70°C -40°C to +70°C Degree of protection (built-in) IP40 IP40 Upper and lower lift terminal capacity 4 - 25 mm 2 4 - 35 mm2 Upper and lower open mouthed terminals for busbar thickness up to 1.5 mm 1.5 mm Tightening torque of terminal screws 2.4 - 3 Nm 2.4 - 3 Nm Quick fastening on DIN rail according to IEC/EN 60715 IEC/EN 60715 Block Diagram Surge Protection Dimensions (mm) Lightning current arrester - surge arrester Sets, Lightning protection classes III, IV SPBT12-280 SPBT12-NPE100 SPBT12- 280/2 SPBT12-280/3 SPBT12-280/4 . . .SPBT12-280
SPD Class B+C, Lightning Current Arrester - Surge Arresters SPBT12-280 Field of application For the protection of low voltage distribution systems against transient overvoltage caused by direct and indirect lightning stroke and switching operations. Application according to IEC 60364-5-53 Clause 534 Test class , in accordance with IEC 61643-1 SPD-type , in accordance with EN 61643-1 1 Lightning protection classes III and IV in accordance with IEC 62305 Busbars ZV-KSBI are available for all customary applications III Technical Data SPBT12-280-1+NPE SPBT12-280-3+NPE Electrical per pole Responding time (rate of voltage rise 5 kV/µs) L -N / N-PE < 25 ns / < 100 ns < 25 ns / < 100 ns Voltage protection level Up L -N / L -PE / N-PE < 1.5kV < 1.5kV Maximum continuous operating voltage UC L -N / N-PE 280 VAC / 255 VAC 280 VAC / 255 VAC Temporary overvoltage test value UT (5 s) L -N / L -PE 348 VAC / 370 VAC 348 VAC / 370 VAC (200 ms) N-PE 1200 VAC 1200 VAC Rated frequency 50/60 Hz 50/60 Hz Open circuit voltage Uoc 10 kV 20 kV Nominal discharge current (8/20) µs In L -N / N-PE 25 kA / 100 kA 3x25 kA / 100 kA Maximum discharge current Imax L -N / N-PE 50 kA / 100 kA 3x50 kA / 100 kA Imulse current Iimp (10/350) µs Peak current L -N / N-PE 12.5 kA / 100 kA 3x12.5 kA / 100 kA Charge Q 50 As 50 As Specific energy 2500 kJ/ Ω 2500 kJ/Ω Follow current interrupt rating Ifi N-PE 100 A r.m.s 100 Ar.m.s Maximum back-up fuse 160 AgL/gG 160 AgL/gG Maximum short-circuit current 50 kA r.m.s 50 kAr.m.s Connection diagram Mechanical Frame size 45 mm 45 mm Device height 80 mm 80 mm Device width 52.5 mm 87 .5 mm Weight 375 g 626 g Permitted ambient temperature -40°C to +70°C -40°C to +70°C Degree of protection (built-in) IP40 IP40 Upper and lower lift terminal capacity L, N 4 - 25 mm 2 4 - 25 mm2 N, PE 4 - 35 mm 2 4 - 35 mm2 Upper and lower open mouthed terminals for busbar thickness up to 1.5 mm 1.5 mm Tightening torque of terminal screws 2.4 - 3 Nm 2.4 - 3 Nm Quick fastening on DIN rail according to IEC/EN 60715 IEC/EN 60715 Block Diagram L N PE Lightning current arrester - surge arrester Sets, Lightning protection classes III, IV N PE L2 L3 SPBT12-280-1+NPE SPBT12-280-3+NPE . . .SPBT12-280 . . .ASAUXSC-SPM . . .SPI-100/NPE . . .ASLTT -63SPBT12-280-3+NPE/BB SPBT12-280-1+NPE-AX SPBT12-280-3+NPE-AX
SPD Class B+C, SP-B+C/ Lightning current arrester - surge arrester Sets, Lightning protection classes I, II, III, IV Surge Protection Field of application: For the protection of low voltage distribution systems against direct lightning stroke into the overhead power supply line or exter- nal lightning protection system (IEC 62305) and against indirect lightning stroke and switching operations. Application according to IEC 60364-5-53 Clause 534 Test class and in accordance with IEC 61643-1 SPD-type and in accordance with EN 61643-1 1 Capsuled version: during the discharge process, the device does not issue any hot ionised gases. Therefore, there is no need for keeping a safety dis- tance to flammable materials. III Technical Data SP-B+C/3 SP-B+C/3+1 Electrical Design capsuled capsuled Responding time tr < 25 ns < 25 ns Voltage protection level Up 1.5 kV 1.5 kV Maximum continuous operating voltage UC L -(PE)N / N-PE 440 VAC / – 440 VAC / 260 VAC Temporary overvoltage test value UT L -(PE)N U T = Uc UT = Uc N-PE – 1200 VAC (200 ms) Rated frequency 50/60 Hz 50/60 Hz Discharge current (8/20) µs Imax/In 3x35 kA 100 kA Impulse current Iimp (10/350) µs Peak current 100 kA 100 kA Charge Q 50 As 50 As Specific energy 2500 kJ/ Ω 2500 kJ/Ω Follow current interrupt rating Ifi L -(PE)N / N-PE at 260 V 3kA rms / – 3kA rms / 100Arms at 440 V 1,5kA rms / – 1,5kA rms / – Short-circuit current strength at max. back-up fuse 25kA rms 25kArms Maximum back-up fuse 125 AgL 125 AgL Connection diagram Mechanical Frame size 45 mm 45 mm Device height 90 mm 90 mm Device width 1 10 mm 164 mm Weight 1 100 g 1420 g Upper and lower lift terminal capacity rigid L, N, PEN / PE 0.5 - 35 mm 2 0.5 - 35 mm2 / 10 - 50 mm2 flexible L, N, PEN / PE 0.5 - 25 mm 2 0.5 - 25 mm2 / 16 - 35 mm2 Tightening torque of terminal screws 4 - 4.5 Nm 4 - 4.5 Nm / 6 - 8 Nm Mounting quick fastening on DIN rail IEC/EN 60715 Degree of protection acc. to IEC 60529 (installed) IP20 (IP40) Accessories: busbars Z-GV-U/ Permitted relative air humidity < 95% Permitted ambient temperature -40°C to +70°C Dimensions (mm) Installation of lightning current arresters upstream of the meter is subject to co-ordination with the relevant power supply company. Installation of an r.m.s.ective protection cascade (SPD classes B, C, D) requires co-ordinated application of the respective protective devices. This is ensured by a defined line length between protective devices. When using lightning current arresters of type SPI in connection with surge arresters SPC with a maximum continuous operating voltage Uc of 460 V AC, no specific line length or decoupling coils are required. Practical Hint T1 T2 Lightning current arrester - surge arrester . . .SPI-35/440 . . .SPI-100/NPE for protection class I, II, III, IV Lead-through terminal . . .SPB-D-125 Busbar . . .Z-GV-U/6 . . .Z-GV-U/9 . . .Z-GV-16/3P-3TE/6
Busbar Connection Examples according to IEC 60364-5-53 Clause 534 SPD Class B SPI B Lightning current arrester . . .SPI-35/440 . . .SPI-100/NPE for protection class I, II, III, IV SPI-50/NPE for protection class III, IV Lead-through terminal . . .SPB-D-125 Busbar . . .Z-GV-U/2 . . .Z-GV-U/3 . . .Z-GV-U/4 . . .Z-GV-U/4 at SPI-100/NPE Z-GV-U/3 at SPI-50/NPE . . .Z-GV-U/6 (Z-GV-U/5 at SPI-50/NPE) CT1 . .Connection type 1 CT2 . .Connection type 2 3 x 240/415 V AC 3 x 230/400 V AC 3 x 220/380 V AC TN-C-System TT -System 3 x 230 VAC IT -System 3 x 230 VAC SPI-35/440/3 4 wires 2 wires SPI-35/440/3 4 wires 3 wires 3 x 240/415 V AC 3 x 230/400 V AC 3 x 220/380 V AC TN-S-System TT -System IT -System 3 x 230/400 VAC SPI-3+1 CT2 CT2 5 wires 3 wires TN-S-System CT1 CT1 5 wires 3 wires
Busbar Connection Examples according to IEC 60364-5-53 Clause 534 SPD Class B+C SPI B SPC C Lightning current arrester . . .SPI-35/440 . . .SPI-100/NPE for protection class I, II, III, IV SPI-50/NPE for protection class III, IV . . .SPCT2-460/3 Lead-through terminal . . .SPB-D-125 Busbar . . .Z-GV-U/6 . . .Z-GV-U/9 . . .Z-GV-16/3P-3TE/6 CT2 . .Connection type 2 3 x 240/415 V AC 3 x 230/400 V AC 3 x 220/380 V AC TN-C-System TT -System 3 x 230 VAC IT -System 3 x 230 VAC SP-B+C/3 4 wires SP-B+C/3 4 wires 3 x 240/415 V AC 3 x 230/400 V AC 3 x 220/380 V AC TN-S-System TT -System IT -System 3 x 230/400 VAC SP-B+C/3+1 CT2 5 wires Surge Protection
Application Examples according to IEC 60364-5-53 Clause 534 Lightning current arrester . . .SPI-35/440 . . .SPI-100/NPE . . .SPI-50/NPE Surge arrester . . .SPCT2-460/3 Lead-through terminal . . .SPB-D-125 . . .ASLTT -63 Busbar . . .ZV-KSBI-4TE Protection Class I, II, III, IV Protection Class III, IV Main distribution board Lightning current arrester Sub-distribu- tion board Main distribution board Lightning current arrester Sub-distribu- tion board Main distribution board Lightning current arrester Sub-distribu- tion board
SPD Class C, Surge Arresters SPC-E Field of application For the protection of low voltage distribution systems against transient overvoltage caused by indirect lightning stroke and switching operations. Test class according to IEC 61643-1+A1 SPD-type according to EN 61643-1 1 Busbars ZV-KSBI are available for all customary applications Suitable for busbar connection to all Xtra Combinations switchgear Technical Data SPC-E-75 -130 -175 -280 -335 -385 -460 -580 Electrical Responding time (rate of voltage rise 5 kV/µs) < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns Voltage protection level at 5 kA (8/20) µs 400 V 550 V 700 V 1000 V 1200 V 1350 V 1700 V 2000 V Maximum continuous operating voltage UC 75 VAC 130 VAC 175 VAC 280 VAC 335 VAC 385 VAC 460 VAC 580 VAC Temporary overvoltage test value UT (5 s) = U c = Uc = Uc 350 VAC 415 VAC 415 VAC 580 VAC = U c Rated frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Nominal discharge current (8/20) µs In 15 kA 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA Maximum discharge current Imax 30 kA 40 kA 40 kA 40 kA 40 kA 40 kA 40 kA 40 kA Permissible back-up fuse Maximum short-circuit current Connection diagram Mechanical Frame size 45 mm Device height 80 mm Device width 17 .5 mm Weight 97 g Permitted ambient temperature -40°C to +70°C Degree of protection (built-in) IP40 Upper and lower lift terminal capacity 4 - 25 mm 2 Upper and lower open mouthed terminals for busbar thickness up to 1.5 mm Tightening torque of terminal screws 2.4 - 3 Nm Quick fastening on DIN rail according to IEC/EN 60715 Accessories: busbars 16 mm2 Type ZV-KSBI ... Block Diagram II Surge Protection ≤ 125 AgL 50 kAr.m.s. PLHT -C100 20 kAr.m.s.
Responding time (rate of voltage rise 5 kV/µs) < 100 ns Voltage protection level at nominal discharge current < 1.0 kV Maximum continuous operating voltage UC 260 VAC Temporary overvoltage test value UT (200 ms) 1200 VAC Rated frequency 50/60 Hz Nominal discharge current (8/20) µs In 20 kA Charge Q at In 0.57 As Specific energy at In 5.7 kJ/Ω Maximum discharge current Imax 40 kA Follow current interrupt rating Ifi 100 Ar.m.s Maximum back-up fuse – Maximum short-circuit current – Connection diagram Mechanical Frame size 45 mm Device height 80 mm Device width 17 .5 mm Weight 97 g Permitted ambient temperature -40°C to +70°C Degree of protection (built-in) IP40 Upper and lower lift terminal capacity 4 - 25 mm 2 Upper and lower open mouthed terminals for busbar thickness up to 1.5 mm Tightening torque of terminal screws 2.4 - 3 Nm Quick fastening on DIN rail according to IEC/EN 60715 Accessories: busbars 16 mm2 Type ZV-KSBI ... Dimensions (mm) Application Examples SPC-E according to IEC 60364-5-53 Clause 534 SPC-E-280 SPC-E-280 SPC-E-460 SPC-E-460SPC-E-280 SPC-E-280 SPC- N/PE D63 SPC- N/PE D63 SPC- 280G
SPD Class C, Plug-in Surge Arresters SPCT2 Field of application: For the protection of low voltage distribution systems against transient overvoltage caused by indirect lightning stroke and switching operations. Test class according to IEC 61643-1+A1 SPD-type according to EN 61643-1 1 Auxiliary switch SPC-S-HK for remote message transmission can be mount- ed onto the device Suitable for busbar connection to all Xtra Combinations switchgear Busbars ZV-KSBI are available for all customary applications Technical Data Inserts SPCT2-075 SPCT2-130 SPCT2-175 SPCT2-280 SPCT2-335 SPCT2-385 SPCT2-460 Electrical Mechanical coding xxxxxxx Responding time (rate of voltage rise 5 kV/µs) < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns Voltage protection level at 5 kA (8/20) µs 400 V 550 V 700 V 1000 V 1200 V 1350 V 1700 V Maximum continuous operating voltage Uc 75 VAC 130 VAC 175 VAC 280 VAC 335 VAC 385 VAC 460 VAC Temporary overvoltage test value UT (5 s) = U C = UC = UC 350 VAC 415 VAC 415 VAC 580 VAC Rated frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Open circuit voltage Uoc –––1 0 k V 5 k V –– Nominal discharge current (8/20) µs In 15 kA 20 kA 15 kA 20 kA 20 kA 20 kA 20 kA Maximum discharge current Imax 30 kA 40 kA 40 kA 40 kA 40 kA 40 kA 40 kA Follow current interrupt rating Ifi ––––––– Permissible back-up fuse Maximum short-circuit current Connection diagram Mechanical Frame size 45 mm Device height 80 mm Device width 1-pole 17 .5 mm (1MU) 1+1-pole 35 mm (2MU) 2-pole 35 mm (2MU) 3-pole 52.5 mm (3MU) 3+1-pole 70 mm (4MU) 4-pole 70 mm (4MU) Mechanical coding 1-pole x 1+1-pole yx 2-pole xx 3-pole xxx 3+1-pole yxxx 4-pole xxxx Weight Base 1P , 1+1P , 2P , 3P , 3+1P , 4P 53/120/120/180/240/240 g Weight Complete Devices 1P , 1+1P , 2P , 3P , 3+1P , 4P 1 10/201/220/330/412/440 g Permitted ambient temperature -40°C to +70°C Degree of protection (built-in) IP40 Upper and lower lift terminal capacity 4 - 25 mm 2 Upper and lower open mouthed terminals for busbar thickness up to 1.5 mm Tightening torque of terminal screws 2.4 - 3 Nm Quick fastening on DIN rail according to IEC/EN 60715 Accessories: busbars 16 mm2 Type ZV-KSBI ... Symbol II ≤ 125 AgL 50 kAr.m.s. PLHT -C100 20 kAr.m.s.
Inserts SPCT2-580 SPCT2-NPE Electrical Mechanical coding x y Responding time (rate of voltage rise 5 kV/µs) < 25 ns < 100 ns Voltage protection level at nominal discharge current / Uoc < 2.6 kV < 1.0 kV Voltage protection level at 5 kA (8/20) µs 2000 V – Maximum continuous operating voltage Uc 580 VAC 260 VAC Temporary overvoltage test value UT = UC (5 s) 1200 VAC (200 ms) Rated frequency 50/60 Hz 50/60 Hz Nominal discharge current (8/20) µs In 20 kA 20 kA Charge Q at In 0.57 As 0.57 As Specific energy at In 5.7 kJ/Ω 5.7 kJ/Ω Maximum discharge current Imax 40 kA 40 kA Follow current interrupt rating Ifi –1 0 0 A r.m.s Permissible back-up fuse – Maximum short-circuit current – Connection diagram Mechanical Frame size 45 mm Device height 80 mm Device width 1-pole 17 .5 mm (1MU) 1+1-pole 35 mm (2MU) 2-pole 35 mm (2MU) 3-pole 52.5 mm (3MU) 3+1-pole 70 mm (4MU) 4-pole 70 mm (4MU) Mechanical coding 1-pole x 1+1-pole yx 2-pole xx 3-pole xxx 3+1-pole yxxx 4-pole xxxx Weight Base 1P , 1+1P , 2P , 3P , 3+1P , 4P 53/120/120/180/240/240 g Weight Complete Devices 1P , 1+1P , 2P , 3P , 3+1P , 4P 1 10/201/220/330/412/440 g Permitted ambient temperature -40°C to +70°C Degree of protection (built-in) IP40 Upper and lower lift terminal capacity 4 - 25 mm 2 Upper and lower open mouthed terminals for busbar thickness up to 1.5 mm Tightening torque of terminal screws 2.4 - 3 Nm Quick fastening on DIN rail according to IEC/EN 60715 Accessories: busbars 16 mm2 Type ZV-KSBI ... Dimensions (mm) ≤ 125 AgL 50 kAr.m.s. PLHT -C100 20 kAr.m.s.
SPD Class C, Plug-in Surge Arresters SPC-S Field of application: For the protection of low voltage distribution systems against transient overvoltage caused by indirect lightning stroke and switching operations. Test class according to IEC 61643-1+A1 SPD-type according to EN 61643-1 1 Auxiliary switch SPC-S-HK for remote message transmission can be mount- ed onto the device Suitable for busbar connection to all Xtra Combinations switchgear Busbars ZV-KSBI are available for all customary applications Technical Data Inserts SPC-S-15/75 -20/130 -20/175 -20/280 -20/335 -20/385 -20/460 Electrical Mechanical coding x x x xxxx Responding time (rate of voltage rise 5 kV/µs) < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns Voltage protection level at 5 kA (8/20) µs 400 V 550 V 700 V 1000 V 1200 V 1350 V 1700 V Maximum continuous operating voltage Uc 75 VAC 130 VAC 175 VAC 280 VAC 335 VAC 385 VAC 460 VAC Temporary overvoltage test value UT (5 s) = U C = UC = UC 350 VAC 415 VAC 415 VAC 580 VAC Rated frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Open circuit voltage Uoc –––1 0 k V 5 k V –– Nominal discharge current (8/20) µs In 15 kA 20 kA 15 kA 20 kA 20 kA 20 kA 20 kA Maximum discharge current Imax 30 kA 40 kA 40 kA 40 kA 40 kA 40 kA 40 kA Follow current interrupt rating Ifi ––––––– Permissible back-up fuse Maximum short-circuit current Connection diagram Mechanical Frame size 45 mm Device height 80 mm Device width 1-pole 17 .5 mm (1MU) 1+1-pole 35 mm (2MU) 2-pole 35 mm (2MU) 3-pole 52.5 mm (3MU) 3+1-pole 70 mm (4MU) 4-pole 70 mm (4MU) Mechanical coding 1-pole x 1+1-pole yx 2-pole xx 3-pole xxx 3+1-pole yxxx 4-pole xxxx Weight Base 1P , 1+1P , 2P , 3P , 3+1P , 4P 53/120/120/180/240/240 g Weight Complete Devices 1P , 1+1P , 2P , 3P , 3+1P , 4P 1 10/201/220/330/412/440 g Permitted ambient temperature -40°C to +70°C Degree of protection (built-in) IP40 Upper and lower lift terminal capacity 4 - 25 mm 2 Upper and lower open mouthed terminals for busbar thickness up to 1.5 mm Tightening torque of terminal screws 2.4 - 3 Nm Quick fastening on DIN rail according to IEC/EN 60715 Accessories: busbars 16 mm2 Type ZV-KSBI ... Symbol II Surge Protection ≤ 160 AgL 50 kAr.m.s. PLHT -C100 20 kAr.m.s.
Inserts SPC-S-20/580 -N/PE Electrical Mechanical coding x y Responding time (rate of voltage rise 5 kV/µs) < 25 ns < 100 ns Voltage protection level at nominal discharge current / Uoc < 2.6 kV < 1.0 kV Voltage protection level at 5 kA (8/20) µs 2000 V – Maximum continuous operating voltage Uc 580 VAC 260 VAC Temporary overvoltage test value UT = UC (5 s) 1200 VAC (200 ms) Rated frequency 50/60 Hz 50/60 Hz Nominal discharge current (8/20) µs In 20 kA 20 kA Charge Q at In 0.57 As 0.57 As Specific energy at In 5.7 kJ/Ω 5.7 kJ/Ω Maximum discharge current Imax 40 kA 40 kA Follow current interrupt rating Ifi –1 0 0 A r.m.s Permissible back-up fuse – Maximum short-circuit current – Connection diagram Mechanical Frame size 45 mm Device height 80 mm Device width 1-pole 17 .5 mm (1MU) 1+1-pole 35 mm (2MU) 2-pole 35 mm (2MU) 3-pole 52.5 mm (3MU) 3+1-pole 70 mm (4MU) 4-pole 70 mm (4MU) Mechanical coding 1-pole x 1+1-pole yx 2-pole xx 3-pole xxx 3+1-pole yxxx 4-pole xxxx Weight Base 1P , 1+1P , 2P , 3P , 3+1P , 4P 53/120/120/180/240/240 g Weight Complete Devices 1P , 1+1P , 2P , 3P , 3+1P , 4P 1 10/201/220/330/412/440 g Permitted ambient temperature -40°C to +70°C Degree of protection (built-in) IP40 Upper and lower lift terminal capacity 4 - 25 mm 2 Upper and lower open mouthed terminals for busbar thickness up to 1.5 mm Tightening torque of terminal screws 2.4 - 3 Nm Quick fastening on DIN rail according to IEC/EN 60715 Accessories: busbars 16 mm2 Type ZV-KSBI ... Dimensions (mm) ≤ 160 AgL 50 kAr.m.s. PLHT -C100 20 kAr.m.s.
SPD Class C, Surge Arresters SPCT2-1+NPE, SPCT2-3+NPE Field of application: For the protection of low voltage distribution systems against transient overvoltage caused by indirect lightning stroke and switching operations. Test class according to IEC 61643-1+A1 SPD-type according to EN 61643-1 1 Auxiliary switch SPC-S-HK for remote message transmission can be mount- ed onto the device Suitable for busbar connection to all Xtra Combinations switchgear Type SPC-S-3+1: consists of 1 base SPC-S-S4-3+1, 1 insert SPC-S-N/PE and 3 inserts SPC-S-20/335 Type SPC-S-1+1: consists of 1 base SPC-S-S2-1+1, 1 insert SPC-S-N/PE and 1 insert SPC-S-20/335 Technical Data SPCT2-1+NPE SPCT2-3+NPE Electrical Mechanical coding yx yxxx Responding time (rate of voltage rise 5 kV/µs) L -N/N-PE/L -PE < 25ns/< 100ns/< 100ns < 25ns/< 100ns/< 100ns Maximum continuous operating voltage UC L -N/N-PE 335VAC/260VAC 280VAC/260VAC Temporary overvoltage test value UT (5 s) L -N 415 VAC 350 VAC (200 ms) N-PE 1200 VAC 1200 VAC Rated frequency 50/60 Hz 50/60 Hz Nominal discharge current In L -N/N-PE/L -PE 20 kA (8/20)µs 20 kA (8/20)µs Voltage protection level Up at In L -N/N-PE/L -PE ≤1600V/≤1000V/≤1650V ≤1000V/≤1000V/≤1300V Maximum discharge current Imax L -N/N-PE/L -PE 40 kA (8/20)µs 40 kA (8/20)µs Permissible back-up fuse Maximum short-circuit current Connection diagram x x x x yy Mechanical Mechanical coding of base yx yxxx Frame size 45 mm 45 mm Device height 80 mm 80 mm Device width 35 mm 70 mm Weight 201 g 412 g Upper and lower lift terminal capacity 1 - 25 mm 2 1 - 25 mm2 Open-mouthed terminals at both sides for busbar thickness up to 1.5 mm 1.5 mm Tightening torque of terminal screws 2.4 - 3 Nm 2.4 - 3 Nm Permitted ambient temperature -40°C to +70°C -40°C to +70°C Mounting quick fastening on DIN rail IEC/EN 60715 Degree of protection (built-in) IP40 IP40 Dimensions (mm) II NN L2L1 Application Examples ≤ 125 AgL 50 kAr.m.s. PLHT -C100 20 kAr.m.s. SPCT2-1+NPE SPCT2-3+NPE
Content The 3+1 circuit offers a universal solution for surge protection in low volt- age distribution systems Suitable for TT - and TN-S systems according to IEC 60364-5-53 Clause 534 Remote message transmission is possibly by mounting auxiliary switch ASAUXSC-SPM Busbar connected, minimum installation work required SPCT2-335-3+NPE/BB - 1 unit SPC-S-3+1 surge arrester - 1 unit ASLTT -63 lead-through terminal - busbar included Surge Arrester Set SPCT2-335-3+NPE/BB SPD Class C, SPCT2 Surge arrester Sets
Auxiliary Switch for (Lightning Current Arrester-)Surge Arrester ASAUXSC-SPM Field of application: For mounting onto surge protective devices for external defect message transmission Design basically in accordance with IEC 60947-5-1 Can be mounted subsequently Suitable for SPBT12-280/1, SPCT2 Technical Data Electrical Rated insulation voltage 250 V Rated frequency 50/60 Hz Switching contact 1 NC + 1 NO Minimum voltage per contact 24 VAC Rated operational current AC12 2A/250VAC Maximum back-up fuse 2 A gL Overvoltage category IV Pollution degree 2 Mechanical Frame size 45 mm Device height 80 mm Device width 8.8 mm Weight 41 g Mounting screw-mounting Degree of protection, built-in IP40 Finger and hand touch safe acc. to BGV A3, ÖVE-EN 6 Upper and lower terminals lift terminals Terminal capacity 2 x 2.5 mm 2 Tightening torque of terminal screws 0.8 - 1 Nm Connection diagram Dimensions (mm) Surge Protection Application Examples ASAUXSC-SPM SPCT2 SPCT2 SPCT2
Lead-Through Terminal for Surge Protective Devices, Class B, SPB-D-125 The lead-through terminal permits orderly wiring of SPDs of class B. It serves as lead-through terminal in circuits requiring vertical connections from the upper to the lower SPD connection level.Technical Data Electrical Design basically in accordance with IEC 61643-1: 1998-02, DIN VDE 0675 Part 6: 1989-1 1, IEC 61024-1: 1990-03, IEC 60947-7-1: 1989-10, DIN VDE 01 10-1: 1997-04 Rated voltage UC 500 V AC/DC Rated current IN 125 A / 30°C Impulse current (10/350) µs Peak current 100 kA Charge Q 50 As Specific energy 2,5 MJ/ Ω Overvoltage category III Mechanical Frame size 45 mm Device height 90 mm Device width 17 .5 mm Mounting quick fastening on DIN rail IEC/EN 60715 Degree of protection, built-in IP40 Upper and lower terminals lift and open-mouthed terminals Terminal capacity rigid 0.5 - 35 mm 2 flexible 0.5 - 25 mm 2 Tightening torque of terminal screws 4-4.5 Nm Permitted relative air humidity < 95% Pollution degree 2 Resistance to climatic conditions F / DIN 40040 Creepage a. clearance distances acc. to IEC 60664-1, DIN VDE 01 10-1:1997-04 Temperature range -40 to +85°C Connection diagram Dimensions (mm) Connection type 2 according to IEC 60364-5-53 Clause 534 TT -System, TN-S-System , IT - System with Neutral Lightning current arrester . . . SPI-35/440 . . . SPI-100/NPE . . . SPI-50/NPE Lead-through terminal . . . SPB-D-125 Busbar . . . Z-GV-U/5 . . . Z-GV-U/6
Lead-Through Terminal for Surge Protective Devices, ASLTT -63 The lead-through terminal permits orderly wiring of SPDs. It serves as lead-through terminal in circuits requiring vertical connections from the upper to the lower SPD connection level. 1-pole Suitable for standard busbar connection to all Xtra Combination switchgear Technical Data Electrical Rated voltage 500V AC/DC Rated current 63 A Rated frequency 50/60 Hz Mechanical Frame size 45 mm Device height 80 mm Device width 17 .5 mm Mounting quick fastening on DIN rail IEC/EN 60715 Degree of protection, built-in IP40 Finger and hand touch safe acc. to BGV A3, ÖVE-EN 6 Upper and lower terminals lift and open-mouthed terminals Terminal capacity 1 - 25 mm 2 Busbar thickness 0.8 - 2 mm Tightening torque of terminal screws 2.4 - 3 Nm Connection diagram Dimensions (mm) Application Example / Connection type 2 acc. to IEC 60364- 5-53 Clause 534 SPCT2-335- 3+NPE/BB ASLT T-63 Surge Protection
Photovoltaic - Surge Protection SPD-type T2 (Class C), Plug-in Surge Arresters SPPT2PA-...-2PE Field of application: For the protection of photovoltaic systems against transient overvoltage caused by indirect lightning stroke and switching operations. Test class according to IEC 61643-1 SPD-type according to EN 61643-1 1 Types SPPT2PA-...-AX for remote message transmission of defective inserts Connection diagrams II SPPT2PA-...-2PE Technical Data SPPT2PA-600-2PE SPPT2PA-1000-2PE(-AX) Electrical Responding time ≤ 25 ns ≤ 25 ns Maximum continuous operating voltage UC 600 V DC 1000 V DC Rated frequency DC DC Nominal discharge current In 15 kA (8/20) µs 15 kA (8/20) µs Voltage protection level Up ≤ 3 kV ≤ 5 kV Residual voltage at 5 kA (8/20) µs ≤ 2.5 kV ≤ 4 kV Maximum discharge current Imax 30 kA (8/20) µs 30 kA (8/20) µs Permissible back-up fuse – – Maximum short-circuit current Isc 80 A 80 A Residual current IPE ≤ 20 µA ≤ 20 µA Mechanical Frame size 45 mm 45 mm Device height 90 mm 90 mm (99 mm) Device width 35.6 mm 35.6 mm Weight 247 g 247 g (249 g) Upper and lower lift terminal capacity fine- / solid strand 4-25/4-35 mm 2/AWG1 1-2 4-25/4-35 mm 2/AWG1 1-2 Tightening torque of terminal screws 4.5 Nm 4.5 Nm Permitted ambient temperature -40°C up to +80°C -40°C up to +80°C Mounting quick fastening on DIN rail IEC/EN 60715 Degree of protection IP20 IP20 Polution degree 2 2 Dimensions (mm) Auxiliary switch Electrical Rated insulation voltage 250 V Rated frequency 50/60 Hz Switching contact 1 CO Minimum voltage per contact 5 V AC/DC Rated operational current 1.5 A / 250 V AC
1.5 A / 30 V DC
Min. admissible power 5 mA / 5 V Mechanical Terminal capacity fine- / solid strand 1.5/1.5 mm 2/AWG28-16 Tightening torque of terminal screws 0.25 Nm Application hints according to EN 50539-12 DC
Photovoltaic - Surge Protection SPD-type T2 (Class C), Plug-in Surge Arresters SPPT2PA-...-2+1PE Field of application: For the protection of photovoltaic systems against transient overvoltage caused by indirect lightning stroke and switching operations. Test class according to IEC 61643-1 SPD-type according to EN 61643-1 1 Galvanic seperation in unearthed systems by means of a spark gap Types SPPT2PA-...-AX for remote message transmission of defective inserts Connection diagrams II SPPT2PA-...-2+1PE Technical Data SPPT2PA-600-2+1PE SPPT2PA-1000-2+1PE(-AX) Electrical Responding time L+ -> L - / L -> PE ≤ 25 ns / ≤ 100 ns ≤ 25 ns / ≤ 100 ns Maximum continuous operating voltage UC 600 V DC 1000 V DC Rated frequency DC DC Nominal discharge current In 15 kA (8/20) µs 15 kA (8/20) µs Voltage protection level Up L+ -> L - / L -> PE ≤ 3 kV / ≤ 3 kV ≤ 5 kV / ≤ 3 kV Residual voltage at 5 kA (8/20) µs L+ -> L - / L -> PE ≤ 2.5 kV / ≤ 2 kV ≤ 4 kV / ≤ 2 kV Maximum discharge current Imax 30 kA (8/20) µs 30 kA (8/20) µs Permissible back-up fuse – – Maximum short-circuit current Isc 80 A 80 A Residual current IPE ≤ 20 µA ≤ 20 µA Mechanical Frame size 45 mm 45 mm Device height 90 mm 90 mm (99 mm) Device width 53.4 mm 53.4 mm Weight 318 g 318 g (323 g) Upper and lower lift terminal capacity fine- / solid strand 4-25/4-35 mm 2/AWG1 1-2 4-25/4-35 mm 2/AWG1 1-2 Tightening torque of terminal screws 4.5 Nm 4.5 Nm Permitted ambient temperature -40°C up to +80°C -40°C up to +80°C Mounting quick fastening on DIN rail IEC/EN 60715 Degree of protection IP20 IP20 Polution degree 2 2 Dimensions (mm) Auxiliary switch Electrical Rated insulation voltage 250 V Rated frequency 50/60 Hz Switching contact 1 CO Minimum voltage per contact 5 V AC/DC Rated operational current 1.5 A / 250 V AC Min. admissible power 5 mA / 5 V Mechanical Terminal capacity fine- / solid strand 1.5/1.5 mm 2/AWG28-16 Tightening torque of terminal screws 0.25 Nm Application hints according to EN 50539-12 DC
Photovoltaic - Surge Protection Auxiliary Switch for Surge Arresters ASAUXSC-SPM Field of application: For mounting onto surge protective devices for external defect message transmission Design basically in accordance with IEC 60947-5-1 Can be mounted subsequently Suitable for SPMT2PA Technical Data Electrical Rated insulation voltage 250 V Rated frequency 50/60 Hz Switching contact 1 CO Minimum voltage per contact 24 VAC Rated operational current AC12 2A/250VAC Maximum back-up fuse 2 A gL Overvoltage category IV Pollution degree 2 Mechanical Frame size 45 mm Device height 80 mm Device width 8.8 mm Weight 41 g Mounting screw-mounting Degree of protection, built-in IP40 Finger and hand touch safe acc. to BGV A3, ÖVE-EN 6 Upper and lower terminals lift terminals Terminal capacity 2 x 2.5 mm 2 Tightening torque of terminal screws 0.8 - 1 Nm Connection diagram Dimensions (mm) Application Examples SPCT2-280/2 SPBT12-280/3 SPCT2-460/4 AC Lead-Through Terminal for Surge Protective Devices, SPD-type 2 (Class C), ASLTT -63 The lead-through terminal permits orderly wiring of SPDs types 2 (class C). It serves as lead-through terminal in circuits requiring vertical connections from the upper to the lower SPD connection level. 1-pole Suitable for standard busbar connection to EATON switchgear Technical Data Electrical Rated voltage 690V AC/DC Rated current 63 A Rated frequency 50/60 Hz Mechanical Frame size 45 mm Device height 80 mm Device width 17 .5 mm Mounting quick fastening on DIN rail IEC/EN 60715 Degree of protection, built-in IP40 Finger and hand touch safe acc. to BGV A3, ÖVE-EN 6 Upper and lower terminals lift and open-mouthed terminals Terminal capacity 1 - 25 mm 2 Busbar thickness 0.8 - 2 mm Tightening torque of terminal screws 2.4 - 3 Nm Connection diagram Dimensions (mm) Application Example / Connection type 2 acc. to IEC 60364-5-53 Clause 534 SPCT2-335- 3+NPE ASLT T-63
Busbars Z-GV-U/ permit to implement customary SPD combinations Suitable for SPI-..., SPB-D-125 The rated cross-section of Z-GV-U/ is 16 mm The busbars must be cut to length in some cases Marking Label SPI-BZS-L/N/PE Can be affixed to SPI-..., SPB-D-125 Size 7 x 17mm Colour: white Technical Data Electrical Rated voltage 230/400 V, 50/60 Hz Rated current 63 A Mechanical Busbar cross section 16 mm 2 Cu Busbars ZV-KSBI Models Busbars ZV-KSBI permit to implement customary SPD combinations The rated cross-section of ZV-KSBI is 16 mm The busbars must be cut to length in some cases Technical Data Electrical Rated voltage 230/400 V, 50/60 Hz Rated current 63 A Mechanical Busbar cross section 16 mm 2 Cu
SPD Class D, Surge Protective Device SPD-S-1+1, SPD-S-280/2 Field of application: For fine protection of user equipment against transient overvoltage For mounting on DIN rails in distribution boxes for electrical installation No decoupling from upstream surge protection in the low voltage distribu- tion system required Test class according to IEC 61643-1+A1 SPD-type according to EN 61643-1 1 Suitable for high back-up fuse 63 A gL / C 63 Auxiliary switch SPC-S-HK for remote message transmission can be mount- ed onto the device Technical Data SPD-S-1+1 SPD-S-280/2 Electrical Mechanical coding yx xx Responding time (rate of voltage rise 5 kV/µs) L -N/N-PE/L -PE < 25ns/< 100ns/< 100ns L1-L2(N)/L2(N)-PE/L1-PE < 25ns Maximum continuous operating voltage UC L -N/N-PE 335VAC/260VAC L1-L2(N)/L2(N)-PE 280VAC Temporary overvoltage test value UT (5 s) L -N/L -PE 350VAC/416VAC L -N/L -PE 350VAC/416VAC (200 ms) N-PE 1200VAC N-PE 1200VAC Rated frequency 50/60 Hz 50/60 Hz Open circuit voltage UOC L -N/N-PE/L -PE 5kV L1-L2(N)/L2(N)-PE/L1-PE 10kV Voltage protection level Up at UOC L -N/N-PE/L -PE≤ 1000V/≤ 900V/≤ 1000V L1-L2(N)/L2(N)-PE ≤ 950V Nominal discharge current In L -N/N-PE/L -PE 2,5kA (8/20)µs L1-L2(N)/L2(N)-PE 5kA (8/20)µs Voltage protection level Up at In L -N/N-PE/L -PE≤ 1000V/≤ 700V/≤ 1000V L1-L2(N)/L2(N)-PE ≤ 950V Maximum discharge current Imax L -N/N-PE/L -PE 10kA (8/20)µs L1-L2(N)/L2(N)-PE/L1-PE 10kA (8/20)µs Follow current interrupt rating Ifi N-PE 100 A r.m.s. – Permissible back-up fuse Maximum short-circuit current Connection diagram xx yx Mechanical Mechanical coding of base yx xx Frame size 45 mm 45 mm Device height 80 mm 80 mm Device width 35 mm 35 mm Weight 220 g 220 g Upper and lower lift terminal capacity 1 - 25 mm 2 1 - 25 mm2 Open-mouthed terminals at both sides for busbar thickness up to 1.5 mm 1.5 mm Tightening torque of terminal screws 2.4 - 3 Nm 2.4 - 3 Nm Permitted ambient temperature -40°C to +70°C -40°C to +70°C Mounting quick fastening on DIN rail IEC/EN 60715 Degree of protection (built-in) IP40 IP40 Dimensions (mm) III Application Examples ≤ 63 AgL 50 kAr.m.s. ≤ C63 10 kAr.m.s.
19” Outlet Strips NWS-STL/19/7F Installation onto 19” rails Installation height: 1U Diagonally arranged socket outlets with earthing contact according to DIN 49440 or NF-C61314 (UTE), 16A / 250VAC Connection cable of 2.5 m H05VV-F 3G1,5 mm 2 with an angled connector Max. power consumption: 3680 W Degree of protection: IP20 Temperature range: -5°C to +40°C Dimensions: 482,6x44x44,45mm (WxDxH) Material: Enclosure made of aluminium, front cover made of plastic similar to RAL 7035 Weight: approx. 0.9 kg Scope of delivery: 1 Outlet strip incl. 19“ fixing bracket, different fixing material 19" Outlet Strips with Surge Protection SPD-STL/19/7F-S/BL Can be mounted on 19“ rails Installation height: 1U Diagonally arranged socket outlets with earthing contact according to DIN 49440 or NF-C61314 (UTE), 16A / 250VAC Connection cable of 2.5 m H05VV-F 3G1,5 mm 2 with an angled connector On/Off switch, 2-pole, lit Max. power consumption: 3680 W Degree of protection: IP20 Temperature range: -5°C up to +40°C Surge protection tested according to IEC 61643-1 (Class: SPD Type 3) Response time: < 25 ns Dimensions: 482,6x44x44,45mm (WxDxH) Material: Enclosure made of aluminium, front cover made of plastic similar to RAL 7035 Weight: approx. 0.9 kg Scope of delivery: 1 Outlet strip incl. 19“ fixing bracket, different fixing material Surge Protection Outlet Strips with High-Grade Filter and Energy Absorption for full Equipment Protection SPD-STL/6F-S Suitable for wall-mounting in indoor areas A 19“ fixing bracket is available as an option for mounting the strip in a cabinet Diagonally arranged socket outlets with earthing contact according to DIN 49440, 10A / 250VAC Connection cable of 1.0 m H05VV-F 3G1,0 mm 2 with an angled connector On/Off switch with MCB that can be reset Max. power consumption: 2500 W Degree of protection: IP20 Temperature range: -15°C to +70°C Surge protection tested according to IEC 61643-1 (Class: SPD Type 3) Response time: < 1 ns Dimensions: 390x42x52mm (WxDxH) Material: Enclosure made of plastic similar to RAL 7021 Weight: approx. 0.4 kg Scope of delivery: 1 Multiple outlet strip 19" Fixing Bracket for SPD-STL/6F-S Fixing bracket for mounting surge protection outlet strips SPD-STL/6F-S on a 19” frame Mounting on 19” rails Installation height: 1U Material: Steel sheet, powder-coated RAL 7035 Weight: approx. 0.4 kg Scope of delivery: 1 Fixing bracket, different fixing material
Earthing/Equipotential Bonding Equipotential Bonding Bar PAS-7x16 Dimensions (mm) Earthing Bar for Antenna Lines PAS-HF-6 Dimensions (mm) Earth Clip EBS Dimensions (mm)