Product: 1315SB Shipboard Speaker, 4 Conductor 14 AWG TC, CMG-LS Product Description Shipboard Speaker, 4 Conductor 14 AWG stranded (41x30) tinned copper conductors, PP insulation, CMG-LS rating, LSZH jacket. Technical Specifications Physical Characteristics (Overall) Conductor AWG Stranding Material Nominal Diameter No. of Conductors 14 41x30 TC - Tinned Copper 0.073 in 4 Conductor Count: 4 Insulation Material Nominal Diameter Nominal Wall Thickness PP - Polypropylene 0.095 in 0.011 in Outer Shield Type No Shield Outer Jacket Material Nominal Diameter Nominal Wall Thickness LSZH - Low Smoke Zero Halogen (Flame Retardant) 0.333 in 0.052 in
Electrical Characteristics
2.42 Ohm/1000ft
Nom. Capacitance Conductor to Conductor 29 pF/ft Inductance Nominal Inductance 0.17 µH/ft Current Max. Recommended Current [A]
17.6 Amps per Conductor at 25ºC
300 V RMS
UL Temp Rating: 105°C Operating Temperature Range: -30°C To +105°C Mechanical Characteristics Max. Pull Tension: 218.400 lbs Min. Bend Radius/Minor Axis: 3.5 in Standards NEC/(UL) Compliance: CMG-LS CEC/C(UL) Compliance: CMG-ST1 IEEE Compliance: Std. 45 clause 23 Applicable Environmental and Other Programs Environmental Space: Indoor/Outdoor EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/11/EC (BFR): Yes EU Directive 2011/65/EU (RoHS 2): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU (RoHS 2 amendment): Yes EU CE Mark: Yes Suitability Suitability - Indoor: Yes Suitability - Outdoor: Yes Suitability - Sunlight Resistance: Yes Flammability, LS0H, Toxicity Testing UL Flammability: UL1685 FT4 Loading, Limited Smoke CSA Flammability: FT4 IEC Flammability: IEC 60332-1-2, IEC 60332-3-22 IEEE Flammability: 1202 UL voltage rating: 300 V RMS Plenum/Non-Plenum Plenum (Y/N): No Related Part Numbers Variants Item # Color Put-Up Type Length UPC 1315SB 0101000 Black Reel 1,000 ft 612825111788 Footnote: C - CRATE REEL PUT-UP. History Update and Revision: Revision Number: 0.251 Revision Date: 11-09-2022 © 2023 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.