1290533 PHOENIX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 11

Technical content

Please be informed that the data shown in this PDF document is generated from our online catalog. Please find the complete data in the user documentation. Our general terms of use for downloads are valid. Ex i-Frequency transducer, the frequencies measured at the Ex i inputs (0.001 Hz ... 20 kHz) are output as 0 mA / 4 mA ... 20 mA non Ex i signals. number of channels: 2, Standard configuration, 5-way isolation, Push-in connection Commercial data Item number 1290533 Packing unit 1 pc Minimum order quantity 1 pc Sales key C430 Product key DK121W GTIN 4063151522704 Weight per piece (including packing) 201.2 g Weight per piece (excluding packing) 160 g Customs tariff number 85437090 Country of origin DE MACX MCR-EX-AP-2F-2I-SP - Frequency measuring transducer 1290533 https://www.phoenixcontact.com/us/products/1290533 Nov 10, 2025, 12:19AM Page 1 (11)

Note on application Accuracy, typically specified as a percentage of the basic measuring range at UN, 23°C Notes on operation Installation conditions influence the ambient temperature. Please refer to the “Control cabinet installation instructions”. Notes on operation Use suitable cables and cable glands for applications below - 20°C. Product properties Product type Frequency value transformer Product family MACX Analog No. of channels 2 Configuration Software System properties Functionality Configuration Software Electrical properties Electrical isolation 5-way isolation Electrical isolation between input and output yes Temperature coefficient, typical ≤ 0.05 % Reverse polarity protection yes Electrical isolation Input/output IEC/EN 60079-11 Standards/regulations IEC/EN 60079-11 Rated insulation voltage 375 VPP Electrical isolation Input/power supply IEC/EN 60079-11 Standards/regulations IEC/EN 60079-11 Rated insulation voltage 375 VPP Electrical isolation Input/error message output IEC/EN 60079-11 Standards/regulations IEC/EN 60079-11 Rated insulation voltage 375 VPP Electrical isolation Input/configuration interface IEC/EN 60079-11 Standards/regulations IEC/EN 60079-11 Rated insulation voltage 375 VPP Electrical isolation Output 1/output 2 Test voltage 350 V (50 Hz, 60 s) MACX MCR-EX-AP-2F-2I-SP - Frequency measuring transducer 1290533 https://www.phoenixcontact.com/us/products/1290533 Nov 10, 2025, 12:19AM Page 2 (11)

Electrical isolation Output/supply Test voltage 350 V (50 Hz, 60 s) Electrical isolation Output/configuration interface Test voltage 350 V (50 Hz, 60 s) Electrical isolation Output/supply/error message output Test voltage 350 V (50 Hz, 60 s) Supply Nominal supply voltage 24 V DC Supply voltage range 18 V ... 31.2 V Power dissipation ≤ 1.5 W Power consumption 1.8 W Input data Measurement: Frequency Description of the input intrinsically safe Available input sources in accordance with IEC/EN 60947-5-6 NAMUR Pulse time 25 µs Frequency measuring range 0.001 Hz ... 20000 Hz < 100 Ω ... 360 Ω (Short circuit) Output data Signal: Error message output Maximum switching voltage 30 V Max. switching current 100 mA Signal: Current 0 mA ... 20 mA (configurable) 4 mA ... 20 mA (configurable) Current output signal 0 mA ... 20.5 mA (Function area) Output current with short-circuit 3.8 mA (Default setting, adjustable) Output current with wire break 20.5 mA (Default setting, adjustable) Load 0 Ω ... 600 Ω < 100 Ω ... 360 Ω (Short circuit) Connection data Connection method Push-in connection Stripping length 8 mm MACX MCR-EX-AP-2F-2I-SP - Frequency measuring transducer 1290533 https://www.phoenixcontact.com/us/products/1290533 Nov 10, 2025, 12:19AM Page 3 (11)

Conductor cross-section AWG 24 ... 16 Ex data Ex installation (EPL) Gc Ga Da Ex i circuits (EPL) Ma Safety data Max. internal inductance Li negligible Max. internal capacitance Ci negligible Max. output voltage Uo 10.5 V Max. output current Io 23.4 mA Max. output power Po 61.4 mW Safety-related maximum voltage Um 253 V AC IIA (simple circuit): Max. external inductivity Lo / Max. external capacitance Co 450 mH / 75 µF IIB/IIIC (simple circuit): Max. external inductivity Lo / Max. external capacitance Co 230 mH / 16.8 µF IIC (simple circuit): Max. external inductivity Lo / Max. external capacitance Co 63 mH / 2.41 µF I (simple circuit): Max. external inductivity Lo / Max. external capacitance Co 600 mH / 95 µF IIA (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co 100 mH / 2.9 µF, 10 mH / 4.5 µF, 1 mH / 7.3 µF, 0.1 mH / 14 µF IIB/IIIC (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co IIC (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co I (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co 100 mH / 4 µF, 10 mH / 5.7 µF, 2 mH / 7.8 µF, 0.1 mH / 17 µF Signaling Green LED (supply voltage)Status display Red LED (line errors) Dimensions Dimensional drawing Width 17.5 mm MACX MCR-EX-AP-2F-2I-SP - Frequency measuring transducer 1290533 https://www.phoenixcontact.com/us/products/1290533 Nov 10, 2025, 12:19AM Page 4 (11)

Height 107.8 mm Depth 113.7 mm Depth NS 35/7,5 114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715) Material specifications Flammability rating according to UL 94 V0 Housing material PA 6.6 Environmental and real-life conditions Ambient conditions IP20 (Terminal blocks)Degree of protection IP30 (Housing) -40 °C ... 70 °C (Stand-alone device: any mounting position) -40 °C ... 50 °C (Group assembly: vertical DIN rail without circulating air) -40 °C ... 65 °C (Group assembly: vertical DIN rail with circulating air) -40 °C ... 65 °C (Group assembly: horizontal DIN rail without circulating air) Ambient temperature (operation) -40 °C ... 70 °C (Group assembly: horizontal DIN rail with circulating air) Ambient temperature (storage/transport) -40 °C ... 80 °C Altitude ≤ 2000 m Permissible humidity (operation) ≤ 95 % (non-condensing) Approvals ATEX  II (1) G [Ex ia Ga] IIC  II (1) D [Ex ia Da] IIIC  II 3 (1) G Ex nA [ia Ga] IIC T4 Gc Identification  I (M1) [Ex ia Ma] I IECEx [Ex ia Ga] IIC [Ex ia Da] IIIC Ex nA nC [ia Ga] IIC T4 Gc Identification [Ex ia Ma] I EMC data Electromagnetic compatibility Tested in accordance with the following standards and regulations: EN 61326-1 For industrial use, NAMUR NE 21 Standards and regulations MACX MCR-EX-AP-2F-2I-SP - Frequency measuring transducer 1290533 https://www.phoenixcontact.com/us/products/1290533 Nov 10, 2025, 12:19AM Page 5 (11)

Electrical isolation 5-way isolation Mounting Mounting type NS 35/15, NS 35/7,5 Mounting position vertical, horizontal MACX MCR-EX-AP-2F-2I-SP - Frequency measuring transducer 1290533 https://www.phoenixcontact.com/us/products/1290533 Nov 10, 2025, 12:19AM Page 6 (11)

114,5 112,5 107,8 (-SP) 17,57 MACX MCR-EX-AP-2F-2I-SP - Frequency measuring transducer 1290533 https://www.phoenixcontact.com/us/products/1290533 Nov 10, 2025, 12:19AM Page 7 (11)

4.3 4.2 4.1 5.3 5.2 5.1 3.3 3.2 3.1 2.3 2.2 2.1 1.3 1.2 1.1 PWR+ I– IN1 OUT2 OUT1 I+I–I+PWR-FM NC NC NC +IN2 NC S-PORT OUTIN passive PWR+ PWR– PLC / DCSSensor / Field passive Zone 2 Zone 0,1,2 Zone 20,21,22 IN 2 + IN 2 - or or or or IN 1 + IN 1 - safe area 4.1 4.2 5.2 5.3 3.1 3.2 2.2 2.3 MACX MCR-EX-AP-2F-2I-SP - Frequency measuring transducer 1290533 https://www.phoenixcontact.com/us/products/1290533 Nov 10, 2025, 12:19AM Page 8 (11)

To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/1290533  IECEx Approval ID: IECEx BVS 21.0018X  ATEX Approval ID: BVS 21 ATEX E 016X MACX MCR-EX-AP-2F-2I-SP - Frequency measuring transducer 1290533 https://www.phoenixcontact.com/us/products/1290533 Nov 10, 2025, 12:19AM Page 9 (11)

ECLASS-13.0 27210128 ECLASS-15.0 27210128 ETIM ETIM 9.0 EC002918 MACX MCR-EX-AP-2F-2I-SP - Frequency measuring transducer 1290533 https://www.phoenixcontact.com/us/products/1290533 Nov 10, 2025, 12:19AM Page 10 (11)

Environmental product compliance EU RoHS Fulfills EU RoHS substance requirements Yes Exemption 6(c), 7(a), 7(c)-I China RoHS EFUP-50Environment friendly use period (EFUP) An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. EU REACH SVHC REACH candidate substance (CAS No.) Lead(CAS: 7439-92-1) SCIP dc3f33d0-e324-4014-be83-fa9f7e0e6421 Phoenix Contact 2025 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA

586 Fulling Mill Road

Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com MACX MCR-EX-AP-2F-2I-SP - Frequency measuring transducer 1290533 https://www.phoenixcontact.com/us/products/1290533 Nov 10, 2025, 12:19AM Page 11 (11)