1174260 COHERENT | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 7
Technical content
High-Sensitivity Thermopile USB and RS-232 Sensors to 2 W Amplified and Thermally Stabilized Thermopiles Sensors with a Wide, Flat Spectral Range for Low Power Laser Measurement with USB and RS-232 Direct Interfaces The PS10 and PS19 sensors are thermally stabilized, amplified thermo- pile thermopile sensors with a broad spectral response, high sensitivity, and a large active area. These sensors are ideal for measuring small laser diodes and HeNe lasers and small ion lasers. Unlike semiconductor detectors, these sensors have a flat broadband output and will not saturate above 1 mW/cm 2. USB and RS-232 sensor models plug directly into a PC or industrial con- troller. Communication with these models can be performed directly via host commands between host and sensor or through our PC software application (included). FEATURES & BENEFITS
- Thermally stabilized designs
- Power measurement from 100 µW to 1 W
- 10 µW resolution
- 10 mm and 19 mm apertures
- Direct USB and RS-232 interfaces
- FC and SMA fiber adapters (optional for PS10, see accessories secton of datasheet)
- RoHS compliant
High-Sensitivity Thermopile USB and RS-232 Sensors to 2 W Datasheet SPECIFICATIONS PS10 PS10Q PS19Q PS19 Wavelength Range (nm) 1903 to 11,000 300 to 2100 300 to 2100 1903 to 11,000 Power Range 100 µW to 1 W 100 µW to 1 W 100 µW to 1 W 100 µW to 1 W Max. Intermittent Power (<5 min.) (W) 3 Long-Pulse Joules (J) 0.001 to 1 Noise Equivalent Power (µW) 3 3 3 5 Maximum Thermal Drift 1 (µW) ±40 ±25 ±25 ±400 Maximum Power Density (W/cm 2) 500 Maximum Energy Density (mJ/cm 2) 50 (10 ns, 1064 nm) Response Time (sec.) (0% to 95%) Speed-up On Speed-up Off Detector Coating Black Detector Element Thermopile Optic None Quartz Quartz None Detector Diameter (mm) 10 10 19 19 Calibration Uncertainty (%) (k=2) ±1 Power Linearity (%) ±1 Spectral Compensation Accuracy (%) ±1.5 Long-Pulse Joules Accuracy (%) ±3 Calibration Wavelength (nm) 514 Cooling Method Air Cable Type USB and RS Cable Length (m) 2.5 (USB)/0.3 (RS) Part Number 2 1174260 (USB) 1287077 (USB) 1288992 (RS) 1168343 (USB) 1179504 (RS) 1174261 (USB) 1 Power stability over 30 minutes in typical lab environment. 2 Software and post stand included. 3 190 nm to 300 nm operation restricted to <100 mW average power and <250 W/cm2 power density. C24 Quick Ship program: eligible for next business day shipment . The PS10 model includes a light tube mounted to the front of the housing, which minimizes the effects of background radiation and narrows the field of view. Alternatively, the light tube can be removed and replaced by a fiber adapter accessory. Where optimum stability is required, the PS10Q or PS19Q include a wedged quartz window, for applications from 0.3 to 2.0 µm. The quartz window more effectively eliminates thermal background radiation and the effects of air currents.
76 mm (3.01 in.) 48 mm (1.91 in.) 39 mm (1.55 in.) 2X 1/4-20 180° Apart 2X M6 180° Apart Ø10 mm (0.39 in.) 10 mm (0.39 in.) Ø84 mm (3.30 in.) Adjustable 207 mm to 162 mm (8.13 in. to 6.36 in.) Aperture Plate Post and Stand Base Detail 51 mm (2.0 in.) 76 mm (3.0 in.) 32 mm (1.25 in.) 10 mm (0.37 in.)63 mm (2.5 in.) 13 mm (0.5 in.) 86 mm (3.38 in.) 7 mm (0.27 in.) Note: Detector Surface is 19.2 mm (0.75 in.) Below Front Face of Aperture Plate 52.3 mm (2.06 in.) 48.5 mm (1.91 in.) 39.3 mm (1.55 in.) 2X M6x1.0 - 6H 12.7 mm (0.50 in.) 180° Apart Ø10 mm (0.39 in.) 9.5 mm (0.38 in.) Ø83.8 mm (3.30 in.) Adjustable 207 mm to 162 mm (8.13 in. to 6.36 in.) Aperture Plate Post and Stand Base Detail 50.8 mm (2.0 in.) 76.2 mm (3.0 in.) 31.8 mm (1.25 in.) 9.5 mm (0.37 in.)63.5 mm (2.5 in.) 12.7 mm (0.5 in.) 85.7 mm (3.38 in.) 6.7 mm (0.27 in.) Note: Detector Surface is 18.3 mm (0.72 in.) Below Front Face of Aperture Plate 2X 1/4-20 UNC 12.7 mm (0.50 in.) 180° Apart High-Sensitivity Thermopile USB and RS-232 Sensors to 2 W Datasheet PS10 PS10Q MECHANICAL SPECIFICATIONS
High-Sensitivity Thermopile USB and RS-232 Sensors to 2 W Datasheet PS19 PS19Q MECHANICAL SPECIFICATIONS 48.5 mm (1.91 in.) 39.3 mm (1.55 in.) 2X M6x1.0 - 6H 12.7 mm (0.50 in.) 180° Apart Ø19.3 mm (0.76 in.) 9.5 mm (0.38 in.) Ø83.8 mm (3.30 in.) R19.1 mm (0.75 in.) Adjustable 207 mm to 162 mm (8.13 in. to 6.36 in.) Aperture Plate 6X 60° Post and Stand Base Detail 50.8 mm (2.0 in.) 76.2 mm (3.0 in.) 31.8 mm (1.25 in.) 9.5 mm (0.37 in.)63.5 mm (2.5 in.) 12.7 mm (0.5 in.) 85.7 mm (3.38 in.) 6.7 mm (0.27 in.) Note: Detector Surface is 18.3 mm (0.72 in.) Below Front Face of Aperture Plate 2X 1/4-20 UNC 12.7 mm (0.50 in.) 180° Apart 6X 6-32 UNC 6.4 mm (0.25 in.) 48 mm (1.91 in.) Ø19 mm (0.76 in.) Ø84 mm (3.30 in.) Adjustable 197 mm to 252 mm (7.75 in. to 9.93 in.) 51 mm (2.00 in.) 51 mm (2.00 in.) 76 mm (3.00 in.) Note: Detector Surface is 16.63 mm (0.66 in.) Below Front Face of Aperture Plate
High-Sensitivity Thermopile USB and RS-232 Sensors to 2 W Datasheet SPECIFICATIONS PM3 PM3Q Wavelength Range (nm) 1903 to 11,000 300 to 2000 Power Range 500 µW to 2 W Max. Intermittent Power (<5 min.) (W) 3 Long-Pulse Joules (J) 0.001 to 1 Noise Equivalent Power (µW) 20 Maximum Thermal Drift 1 (µW) ±1000 ±500 Maximum Power Density (W/cm 2) 500 Maximum Energy Density (mJ/cm 2) 50 (10 ns, 1064 nm) Response Time (sec.) (0% to 95%) Speed-up On Speed-up Off Detector Coating Black Detector Element Thermopile Optic None Quartz Detector Diameter (mm) 19 10 Calibration Uncertainty (%) (k=2) ±1 Power Linearity (%) ±1 Spectral Compensation Accuracy (%) ±1.5 Long-Pulse Joules Accuracy (%) ±3 Calibration Wavelength (nm) 10,600 514 Cooling Method Air Cable Type USB Cable Length (m) 2.5 Part Number 2 1174263 (USB) 1191133 (USB) 1 Power stability over 30 minutes in typical lab environment. 2 Software and post stand included. 3 190 nm to 300 nm operation restricted to <100 mW average power and <250 W/cm2 power density. The PM3 sensors are amplified low-power thermopiles, but they do not contain the temperature-stabilization features of the PS series. The PM3 comes with a 10 mm inner diameter light tube to eliminate stray light; however, this can be removed to make use of the entire 19 mm diameter absorbing surface. The PM3Q replaces the light tube with a wedged quartz window to block spurious ambient thermal emissions from reaching the detector.
High-Sensitivity Thermopile USB and RS-232 Sensors to 2 W Datasheet PM3 PM3Q MECHANICAL SPECIFICATIONS 74 mm (2.91 in.) Light Tube 22 mm (0.87 in.) Light Tube Ø19 mm (0.75 in.)Ø63 mm (2.48 in.) 36 mm (1.40 in.) Adjustable 186 mm to 227 mm (6.81 in. to 8.96 in.) 51 mm (2.00 in.) 51 mm (2.00 in.) 76 mm (3.00 in.) Note: Detector Surface is 11 mm (0.44 in.) Below Front Face of Aperture Plate 38.8 mm (1.53 in.) 35.7 mm (1.40 in.) Ø9.5 mm (0.38 in.) Ø24.1 mm (0.95 in.) 22.8 mm (0.90 in.) 9.5 mm (0.38 in.) Ø63 mm (2.48 in.) Adjustable 193 mm to 148 mm (7.60 in. to 5.83 in.) Aperture Plate Post and Stand Base Detail 50.8 mm (2.0 in.) 76.2 mm (3.0 in.) 31.8 mm (1.25 in.) 9.5 mm (0.37 in.)63.5 mm (2.5 in.) 12.7 mm (0.5 in.) 85.7 mm (3.38 in.) 6.7 mm (0.27 in.) Note: Detector Surface is 11.1 mm (0.44 in.) Below Front Face of Aperture Plate
Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice. Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976. Coherent offers a limited warranty for all High Power Water-Cooled Thermopile Sensors. For full details of this warranty coverage, please refer to the Service section at www.coherent.com or contact your local Sales or Service Representative. MC-011-20-0M0320 Copyright ©2020 Coherent, Inc. Coherent, Inc.,
5100 Patrick Henry Drive Santa Clara, CA 95054
p. (800) 527-3786 | (408) 764-4983 f. (408) 764-4646 tech.sales@coherent.com www.coherent.com High-Sensitivity Thermopile USB and RS-232 Sensors to 2 W Datasheet Fiber-Optic Connector Adapters Part Number: 0012-3860 (PS-SMA-Type Connector) 0012-3863 (PS-FC-Type Connector) The following fiber adapters can be mounted onto the front of the PS10 sensor in place of the removable light tube. -20, LM-45, LM-100, LM-150 LS, and LM-200 sensors. POWER SENSOR ACCESSORIES