1286389 PHOENIX | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 11
Technical content
https://www.phoenixcontact.com/us/products/1286389 08/30/2021 Page 1 / 11 Socket Outlet - EV-T2M3SO12-4P-B-EM - 1286389 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) CHARX connect, Socket Outlet, front protective cover screw connection, can be reconnected, For charging electric vehicles (EV) with alternating current (AC), Compatible with infrastructure charging plugs, Type 2, IEC 62196-2, 32 A / 480 V (AC), without cable, Locking actuator: 12 V, 4-position, Rear panel mounting, Generation 2 Basic, “PHOENIX CONTACT” logo The figure shows the standard item Product Description Infrastructure Socket Outlet for charging electric vehicles (EV) with alternating current (AC), compatible with type 2 Infrastructure Plugs, for installation at charging stations for E-Mobility (EVSE) Your advantages Uniform, space-saving installation space of all Phoenix Contact Infrastructure Socket Outlets Silver-plated surface of the power and signal contacts Developed and produced in accordance with the IATF 16949 automotive standard and ISO 9001 Manual emergency release of the locking actuator Integrated interlock during charging Key Commercial Data Packing unit 1 GTIN GTIN 4063151493660 Custom tariff number 85366990 Technical data Product definition Type front protective cover screw connection can be reconnected Application For charging electric vehicles (EV) with alternating current (AC) Compatible with infrastructure charging plugs Affixed logo “PHOENIX CONTACT” logo Design Generation 2 Basic Standards/regulations IEC 62196-2
https://www.phoenixcontact.com/us/products/1286389 08/30/2021 Page 2 / 11 Socket Outlet - EV-T2M3SO12-4P-B-EM - 1286389 Technical data Product definition Charging standard Type 2 Charging mode Mode 3, Case B Note on the connection method Connection via spade connector, separable Dimensions Height 91.71 mm Width 75 mm Depth 87.95 mm (with attachable cap for strain relief and touch protection, see accessories) 73.35 mm (without attachable cap for strain relief and touch protection, see accessories) Bore dimensions 60 mm x 60 mm Type of conductor without cable Ambient conditions Ambient temperature (operation) -30 °C ... 50 °C Ambient temperature (storage/transport) -40 °C ... 80 °C Max. altitude 5000 m (above sea level) Degree of protection IP44 (plugged in) IP54 (with protective cover, see accessories) Electrical properties Charging power (nominal operation) 22 kW Type of charging current AC 3-phase Number of phases 3 Number of power contacts 5 (L1, L2, L3, N, PE) Rated current of power contacts 32 A Rated voltage for power contacts 480 V AC Number of signal contacts 2 (CP, PP) Rated current for signal contacts 2 A Rated voltage for signal contacts 30 V AC Type of signal transmission Pulse width modulation Note on the connection method Connection via spade connector, separable Mechanical properties Insertion/withdrawal cycles > 10000 Insertion force < 100 N Withdrawal force < 100 N Mounting Possible mounting positions Rear panel mounting
https://www.phoenixcontact.com/us/products/1286389 08/30/2021 Page 3 / 11 Socket Outlet - EV-T2M3SO12-4P-B-EM - 1286389 Technical data Mounting Restrictions to mounting position Only 0 to 90 degree frontal inclination possible, see figure Mounting position of the locking actuator Top center Screw connection of a protective cover Only possible on the front Max. wall thickness max. 22 mm (Rear panel mounting, normative maximum specification for infrastructure plug when using the protective cover (Order No. 1627635) with fastening frame (Order No. 1627637)) Mounting hole diameter 7.00 mm (ø) Design Design line Generation 2 Basic Housing color black Material Material Plastic Material surface of contacts Ag Locking Locking type Locking in the inserted state with a locking mechanism Locking actuator Number of positions of theconnectors 4 Operating voltage 12 V (Typical power supply at the motor) Possible power supply range at the motor 9 V ... 16 V Maximum voltage for locking detection 30 V Typical motor current for locking 0.2 A Reverse current of the motor max. 1 A Max. dwell time with reverse current 1000 ms Recommended adaptation time 600 ms Pause time after entry or exit path 3 s Service life insertion cycles > 10000 load cycles Ambient temperature (operation) -30 °C ... 50 °C Cable length 0.5 m Cable structure 4 x 0.5 mm² Lock recognition available Mechanical emergency release available Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 10; For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
https://www.phoenixcontact.com/us/products/1286389 08/30/2021 Page 4 / 11 Socket Outlet - EV-T2M3SO12-4P-B-EM - 1286389 Drawings Connection diagram PE CP N PP Pin assignment of Infrastructure Socket Outlet Schematic diagram Rear mounting with front protective cover screw connection The screw connection for a protective cover (EV-T2SC-EM) from the accessories range only supports front mounting with a corresponding fixing frame (EV-T2SF-EM). The panel thickness must not exceed 5 mm. The sealing frame that is slid on from the rear must contact the housing panel flush with the flat side and must completely surround the infrastructure socket outlet. Block diagram M PIN 1 – BN Ub+ PIN 2 – YE PIN 3 – GN PIN 4 – RD Ub- Block diagram of the locking actuator Schematic diagram M +Ub -Ub RL RU stall current switch point 1 switch point 2 Locking states of the locking actuator
https://www.phoenixcontact.com/us/products/1286389 08/30/2021 Page 5 / 11 Socket Outlet - EV-T2M3SO12-4P-B-EM - 1286389 Schematic diagram AC Operating instructions Schematic diagram Installation positions
https://www.phoenixcontact.com/us/products/1286389 08/30/2021 Page 6 / 11 Socket Outlet - EV-T2M3SO12-4P-B-EM - 1286389 Schematic diagram R = 0 ΩL R = ∞ ΩU Position of the emergency unlocking lever on the locking actuator
https://www.phoenixcontact.com/us/products/1286389 08/30/2021 Page 7 / 11 Socket Outlet - EV-T2M3SO12-4P-B-EM - 1286389 Classifications eCl@ss eCl@ss 10.0.1 27144706 eCl@ss 11.0 27144706 eCl@ss 9.0 27144706 ETIM ETIM 7.0 EC002898 Accessories Accessories AC charging controller AC charging controller - CHARX SEC-1000 - 1139034 CHARX control modular, AC charging controller according to IEC 61851-1. Configurable charging controller. operating mode Stand-alone or client. interface: CHARX control modular system bus. Connectable peripheral devices: Energy meter, RFID, DC residual current detection. DIN rail mounting AC charging controller - CHARX SEC-3000 - 1139022 CHARX control modular, AC charging controller according to IEC 61851-1. Embedded Linux system. operating mode Stand-alone, server, or client. interface: Ethernet (2x), CHARX control modular system bus, MICRO-USB type C. communication protocol: OCPP 1.6J, Modbus/TCP, MQTT. Connectable peripheral devices: Energy meter, RFID, DC residual current detection. DIN rail mounting AC charging controller - CHARX SEC-3050 - 1139018 CHARX control modular, AC charging controller according to IEC 61851-1, ISO/IEC 15118. Embedded Linux system. operating mode Stand-alone, server, or client. interface: Ethernet (2x), CHARX control modular system bus, MICRO- USB type C. communication protocol: OCPP 1.6J, Modbus/TCP, MQTT. Connectable peripheral devices: Energy meter, RFID, DC residual current detection. DIN rail mounting
https://www.phoenixcontact.com/us/products/1286389 08/30/2021 Page 8 / 11 Socket Outlet - EV-T2M3SO12-4P-B-EM - 1286389 Accessories AC charging controller - CHARX SEC-3100 - 1139012 CHARX control modular, AC charging controller according to IEC 61851-1. Embedded Linux system. operating mode Stand-alone, server, or client. interface: Ethernet (2x), Cellular communication (4G/2G), CHARX control modular system bus, MICRO-USB type C. communication protocol: OCPP 1.6J, Modbus/TCP, MQTT. Connectable peripheral devices: Energy meter, RFID, DC residual current detection. DIN rail mounting AC charging controller - CHARX SEC-3150 - 1138965 CHARX control modular, AC charging controller according to IEC 61851-1, ISO/IEC 15118. Embedded Linux system. operating mode Stand-alone, server, or client. interface: Ethernet (2x), Cellular communication (4G/2G), CHARX control modular system bus, MICRO-USB type C. communication protocol: OCPP 1.6J, Modbus/TCP, MQTT. Connectable peripheral devices: Energy meter, RFID, DC residual current detection. DIN rail mounting AC charging controller - EM-CP-PP-ETH - 2902802 EV charge control is used to charge electrical vehicles on the 3-phase AC mains power supply according to IEC 61851-1 Mode 3. All necessary control functions are integrated. Additional functions are available for various charging applications. Adhesive label Label - EV-LABEL-C-SO - 1315521 CHARX connect, Label, accordance to DIN EN 17186, for AC charging cables and infrastructure charging sockets, Marking C for AC type 2 infrastructure charging plugs and type 2 infrastructure charging sockets Arrester combination Lightning/surge arrester type 1/2 - VAL-EV-T1/T2 264/12.5/3+1 - 1180149 CHARX protect: pluggable lightning current arrester/surge protective device, in accordance with Type 1/2 / Class I/II, for 3-phase power supply networks with separate N and PE (5-conductor system: L1, L2, L3, N, PE). Specifically designed for use in e-mobility.
https://www.phoenixcontact.com/us/products/1286389 08/30/2021 Page 9 / 11 Socket Outlet - EV-T2M3SO12-4P-B-EM - 1286389 Accessories Lightning/surge arrester type 1/2 - VAL-EV-T1/T2 264/12.5/3+1-R - 1180150 CHARX protect: pluggable lightning current arrester/surge protective device, in accordance with Type 1/2 / Class I/II, for 3-phase power supply networks with separate N and PE (5-conductor system: L1, L2, L3, N, PE), with remote indication contact. Specifically designed for use in e-mobility. Type 2 surge arrester - VAL-EV-T2 280/3+1 - 1180144 CHARX protect: pluggable surge protective device, in accordance with Type 2 / Class II, for 3-phase power supply networks with separate N and PE (5-conductor system: L1, L2, L3, N, PE). Specifically designed for use in e-mobility. Type 2 surge arrester - VAL-EV-T2 280/3+1-R - 1180145 CHARX protect: pluggable surge protective device, in accordance with Type 2 / Class II, for 3-phase power supply networks with separate N and PE (5-conductor system: L1, L2, L3, N, PE), with remote indication contact. Specifically designed for use in e-mobility. Assembly tool Tool - EV-T2M3SO-CAP-REMOVER - 1286836 CHARX connect, tool for opening the optional cap for attachment to the back of the Generation 2.0 Basic infrastructure charging socket with functions for strain relief and touch protection. Cable set Cable set - EV-T2M3SOW-1AC32A-0,3M6,0E - 1164343 CHARX connect, Cable set, Cables with slip-on sleeves on one end, Only for connection to generation 2 infrastructure charging sockets from Phoenix Contact, Type 2, IEC 62196-2, 32 A / 250 V (AC), Single wires, length: 0.3 m, Generation 2
https://www.phoenixcontact.com/us/products/1286389 08/30/2021 Page 10 / 11 Socket Outlet - EV-T2M3SO12-4P-B-EM - 1286389 Accessories Cable set - EV-T2M3SOW-3AC20A-0,3M2,5E - 1164355 CHARX connect, Cable set, Cables with slip-on sleeves on one end, Only for connection to generation 2 infrastructure charging sockets from Phoenix Contact, Type 2, IEC 62196-2, 20 A / 480 V (AC), Single wires, length: 0.3 m, Generation 2 Cable set - EV-T2M3SOW-3AC32A-0,3M6,0E - 1164362 CHARX connect, Cable set, Cables with slip-on sleeves on one end, Only for connection to generation 2 infrastructure charging sockets from Phoenix Contact, Type 2, IEC 62196-2, 32 A / 480 V (AC), Single wires, length: 0.3 m, Generation 2 Cable set - EV-T2M3SOW-1AC32A-0,7M6,0E - 1164344 CHARX connect, Cable set, Cables with slip-on sleeves on one end, Only for connection to generation 2 infrastructure charging sockets from Phoenix Contact, Type 2, IEC 62196-2, 32 A / 250 V (AC), Single wires, length: 0.7 m, Generation 2 Cable set - EV-T2M3SOW-3AC20A-0,7M2,5E - 1164361 CHARX connect, Cable set, Cables with slip-on sleeves on one end, Only for connection to generation 2 infrastructure charging sockets from Phoenix Contact, Type 2, IEC 62196-2, 20 A / 480 V (AC), Single wires, length: 0.7 m, Generation 2 Cable set - EV-T2M3SOW-3AC32A-0,7M6,0E - 1164365 CHARX connect, Cable set, Cables with slip-on sleeves on one end, Only for connection to generation 2 infrastructure charging sockets from Phoenix Contact, Type 2, IEC 62196-2, 32 A / 480 V (AC), Single wires, length: 0.7 m, Generation 2 Protective cover for Socket Outlet
https://www.phoenixcontact.com/us/products/1286389 08/30/2021 Page 11 / 11 Socket Outlet - EV-T2M3SO12-4P-B-EM - 1286389 Accessories Protective covers - EV-T2SOC-B - 1164293 CHARX connect, Protective covers, self-closing, rear protective cover screw connection, For attaching to infrastructure charging sockets, Type 2, IEC 62196-2, M5 thread, Generation 2 Basic, Embossed PHOENIX CONTACT logo Strain relief - EV-T2M3SO-CAP - 1202424 CHARX connect, Strain relief, Touch protection, For generation 2.0 infrastructure charging socket, For plugging onto the rear of the infrastructure charging socket, Type 2, IEC 62196-2, Generation 2 Phoenix Contact 2021 © - all rights reserved http://www.phoenixcontact.com