High-Resolution Laser Beam Profiling System LaserCam-HR II is our second generation of digital USB 2.0 bus-powered, high-resolution, large-area cameras. The LaserCam-HR II family includes 1/2-inch and 2/3-inch format CCD cameras that provide greater dynamic range and lower noise than the previous generation. The cameras include Coherent’s BeamView software package, long recognized as a flexible, fast, and user friendly beam diagnostics software platform. The UV model provides long-term UV sensor stability. FEATURES & BENEFITS
- USB 2.0, 12-bit and 14-bit digital output
- Large-area arrays
- Compact 68 x 68 x 43 mm package
- Metric and English mounts included
- CW and pulsed operation including external triggering
- Variable exposure time
- User-variable trigger delay
- C-mount thread for additional accessories OPTIONS & ACCESSORIES
- Scientific
- UV Lasers
- Telecommunication Sources
- Military Laser Systems
Sensor Elements (pixels) 1280 x 1024 Effective Pixel Resolution (µm) n/a n/a 20 x 20 Pixel Size (μm) 4.6 x 4.6 6.5 x 6.5 n/a Camera Bit Depth 12-bit 14-bit 14-bit Spectral Range (nm) without LDFP with LDFP included with BIP-12F accessory 190 to 1100 400 to 1100 190 to 355 190 to 11001 400 to 1100 190 to 355 190 to 355 Capture Modes Continuous (CW), pulsed Variable Exposure Time 1 msec to 500 msec, default at 5 msec 1 msec to 500 msec, default at 5 msec 1 msec to 500 msec, default at 5 msec Trigger Delay (µs) 75 20 20 Maximum Pulse Trigger in Rate 3 (Hz) 200 200 200 Damage Threshold without LDFP 32 mJ/cm 2 at 1064 nm 32 mJ/cm2 at 1064 nm 200 µJ/cm2 at 1064 nm4 CW Saturation with LDFP without LDFP with LDFP without LDFP 13 mW/cm 2 at 633 nm 5 μW/cm2 at 633 nm 70 mW/cm2 at 1064 nm 340 μW/cm2 at 1064 nm 5 mW/cm2 at 633 nm 2 μW/cm2 at 633 nm 25 mW/cm2 at 1064 nm 125 μW/cm2 at 1064 nm 90 mW/cm2 at 248 nm5 90 µW/cm2 at 248 nm4 Pulsed Saturation with LDFP without LDFP 0.4 mJ/cm 2 at 1064 nm 2 μJ/cm2 at 1064 nm 0.15 mJ/cm2 at 1064 nm 0.7 μJ/cm2 at 1064 nm 5 mJ/cm2 at 248 nm5 5 μJ/cm2 at 248 nm4 USB 2.0 Cable 10 ft. standard A/B cable included Trigger Connector BNC receptacle (trigger cable included) Part Number 1282868 1282870 1360550 1 There is a risk of degradation in the range of 190 nm to 300 nm due to DUV exposure. The optional BIP-12F UV-to-visible fluorescence converter can be used to prevent drift. 2 It is possible to measure beams <0.2 mm in diameter, but resolution is reduced. 3 Without averaging adjacent pulses. 4 Without LDFP-UV. 5 With LDFP-UV.
Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice. Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976. Coherent offers a limited warranty for all LaserCam-HR II Beam Diagnostic Cameras. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative. MC-135-02-0M0418Rev.C Copyright ©2018 Coherent, Inc. Coherent, Inc.,
5100 Patrick Henry Drive Santa Clara, CA 95054
p. (800) 527-3786 | (408) 764-4983 f. (408) 764-4646 tech.sales@Coherent.com www.coherent.com Rotational Mount Trigger Connector 1/4-20 UNC 8.9 mm (0.35 in.) USB 68.1 mm (2.68 in.) A 68.1 mm (2.68 in.) Ø 22.0 mm (0.87 in.) Cap Not Shown 45.2 mm (1.78 in.) Ø 36.6 mm (1.44 in.) 34.0 mm (1.34 in.) 9.4 mm (0.37 in.) 16.9 mm (0.67 in.) Image Depth 32.9 mm (1.30 in.) 42.8 mm (1.69 in.) 12.3 mm (0.50 in.) 45.1 mm (1.78 in.) 34.0 mm (1.34 in.) 24.3 mm (0.96 in.)12.9 mm (0.51 in.) 6.3 mm (0.25 in.) 36.6 mm (1.44 in.) 28.2 mm (1.11 in.)A Section A-A Front View Top View Side View MECHANICAL SPECIFICATIONS LaserCam-HR II Datasheet LaserCam-HR II