Please be informed that the data shown in this PDF document is generated from our online catalog. Please find the complete data in the user documentation. Our general terms of use for downloads are valid. Power cable, 4-position, Plug angled M12, coding: L, on free cable end, cable length: Free input Your advantages Easy and safe: 100 % electrically tested plug-in components• Protection against mismatching, thanks to special L-coding Commercial data Item number 1276567 Packing unit 1 pc Minimum order quantity 1 pc Note Made to order (non-returnable) Sales key BF17 Product key BF1CCR Customs tariff number 85444290 Country of origin PL 1276567 https://www.phoenixcontact.com/us/products/1276567 May 28, 2024, 1:07 AM Page 1 (12)

No. of cable outlets 1 Shielded no Coding L Insulation characteristics Overvoltage category III Degree of pollution 3 Material specifications Flammability rating according to UL 94 V0 Material of grip body PP Contact material CuZn Contact surface material Ni/Au Contact carrier material PA Material for screw connection Zinc die-cast, nickel-plated Electrical properties Insulation resistance ≥ 100 MΩ Nominal voltage UN 63 V DC 12 A (1.5 mm²)Nominal current IN 16 A (2.5 mm²) Mechanical properties Mechanical data Insertion/withdrawal cycles ≥ 100 Connector Connection 1 Type Plug angled M12 Coding type L (Power) Connection 2 Type free cable end Cable/line PUR halogen-free black [PUR] 1276567 https://www.phoenixcontact.com/us/products/1276567 May 28, 2024, 1:07 AM Page 2 (12)

UL AWM Style 20233 / 10493 (80°C/300 V) Number of positions 4 Shielded no PUR halogen-free black [PUR]Cable type PUR halogen-free black PUR Conductor structure, voltage supply 141x 0.15 mm AWG power supply 14 Conductor cross section 4x 2.5 mm² Wire diameter incl. insulation 2.85 mm ±0.1 mm External cable diameter 8.80 mm ±0.25 mm Outer sheath, material PUR External sheath, color black-gray RAL 7021 Conductor material Bare Cu litz wires Material wire insulation PP Single wire, color brown, white, blue, black Thickness, insulation ≥ 0.31 mm Thickness, outer sheath approx. 0.76 mm Max. conductor resistance ≤ 8 Ω/km (at 20 °C) Insulation resistance ≥ 1 GΩ*km (at 20 °C) Nominal voltage, cable ≤ 300 V AC Test voltage ≥ 3000 V AC (Spark test) Minimum bending radius, fixed installation 5 x D Minimum bending radius, flexible installation 10 x D Smallest bending radius, fixed installation 44 mm Smallest bending radius, movable installation 88 mm Max. bending cycles 4000000 in accordance with DIN VDE 0472 part 815Halogen-free in accordance with DIN EN 50267-2-1 According to UL 758/1581 (Cable Flame) according to UL 758/1581 FT1 Flame resistance According to DIN EN 60332-1-2 Resistance to oil according to DIN EN 60811-404, 168 h at 100 °C Hydrolysis and microbe resistant as per VDE 0282 section 10 Low adhesion abrasion-resistant Other resistance Resistant to salt water -50 °C ... 80 °C (cable, fixed installation)Ambient temperature (operation) -30 °C ... 80 °C (Cable, flexible installation) PUR halogen-free black [105] Cable weight 109 kg/km UL AWM Style 20233 / 10493 (80°C/300 V) Number of positions 4 1276567 https://www.phoenixcontact.com/us/products/1276567 May 28, 2024, 1:07 AM Page 3 (12)

PUR halogen-free black [105]Cable type PUR halogen-free black 105 Conductor structure, voltage supply 78x 0.15 mm AWG power supply 16 Conductor cross section 4x 1.5 mm² Wire diameter incl. insulation 2.35 mm ±0.05 mm External cable diameter 8.40 mm ±0.25 mm Outer sheath, material PUR External sheath, color black-gray RAL 7021 Conductor material Bare Cu litz wires Material wire insulation PP Single wire, color brown, white, blue, black Thickness, insulation ≥ 0.25 mm Thickness, outer sheath approx. 1.30 mm Overall twist 4 wires, twisted Length of twist, overall twist 90 mm Max. conductor resistance ≤ 13 Ω/km (at 20 °C) Insulation resistance ≥ 1 GΩ*km (at 20 °C) Nominal voltage, cable ≤ 300 V AC Test voltage ≥ 3000 V AC (Spark test) Minimum bending radius, fixed installation 5 x D Minimum bending radius, flexible installation 10 x D Smallest bending radius, fixed installation 42 mm Smallest bending radius, movable installation 84 mm Max. bending cycles 4000000 in accordance with DIN VDE 0472 part 815Halogen-free in accordance with DIN EN 50267-2-1 According to UL 758/1581 (Cable Flame) according to UL 758/1581 FT1 Flame resistance According to DIN EN 60332-1-2 According to DIN EN 60811-2-1, 168 h at 100°CResistance to oil According to UL 758, 168 h at 60°C Hydrolysis and microbe resistant as per VDE 0282 section 10 Low adhesion abrasion-resistant Other resistance Resistant to salt water -50 °C ... 80 °C (cable, fixed installation)Ambient temperature (operation) -30 °C ... 80 °C (Cable, flexible installation) PVC 1.5 mm² black [110] Cable weight 108 kg/km UL AWM Style 20233 / 10493 (80°C/300 V) Number of positions 4 1276567 https://www.phoenixcontact.com/us/products/1276567 May 28, 2024, 1:07 AM Page 4 (12)

PVC 1.5 mm² black [110]Cable type PVC 1.5 mm² black 110 Conductor structure, voltage supply 78x 0.15 mm AWG power supply 16 Conductor cross section 4x 1.5 mm² Wire diameter incl. insulation 2.35 mm ±0.05 mm External cable diameter 7.55 mm ±0.25 mm Outer sheath, material PVC External sheath, color black-gray RAL 7021 Conductor material Bare Cu litz wires Material wire insulation PVC Single wire, color brown, white, blue, black Thickness, insulation ≥ 0.25 mm Thickness, outer sheath approx. 1.30 mm Max. conductor resistance ≤ 13 Ω/km (at 20 °C) Insulation resistance ≥ 1 GΩ*km (at 20 °C) Nominal voltage, cable ≤ 300 V AC Test voltage ≥ 3000 V AC (Spark test) Minimum bending radius, fixed installation 5 x D Minimum bending radius, flexible installation 10 x D Smallest bending radius, fixed installation 38 mm Smallest bending radius, movable installation 76 mm Max. bending cycles 2000000 According to UL 758/1581 (Cable Flame) according to UL 758/1581 FT1 Flame resistance According to DIN EN 60332-1-2 Resistance to oil according to DIN EN 60811-404, 168 h at 60 °C -40 °C ... 80 °C (cable, fixed installation)Ambient temperature (operation) -20 °C ... 80 °C (Cable, flexible installation) PVC black [PVC] Cable weight 168 kg/km UL AWM Style 20233 / 10493 (80°C/300 V) Number of positions 4 Shielded no PVC black [PVC]Cable type PVC black PVC Conductor structure, voltage supply 141x 0.15 mm AWG power supply 14 Conductor cross section 4x 2.5 mm² Wire diameter incl. insulation 3 mm ±0.1 mm External cable diameter 9.50 mm ±0.3 mm Outer sheath, material PVC 1276567 https://www.phoenixcontact.com/us/products/1276567 May 28, 2024, 1:07 AM Page 5 (12)

External sheath, color black-gray RAL 7021 Conductor material Bare Cu litz wires Material wire insulation PVC Single wire, color brown, white, blue, black Thickness, insulation ≥ 0.36 mm Thickness, outer sheath approx. 0.76 mm Max. conductor resistance ≤ 8 Ω/km (at 20 °C) Insulation resistance ≥ 100 MΩ*km (at 20 °C) Nominal voltage, cable ≤ 300 V AC Test voltage ≥ 3000 V AC (Spark test) Minimum bending radius, fixed installation 5 x D Minimum bending radius, flexible installation 10 x D Smallest bending radius, fixed installation 48 mm Smallest bending radius, movable installation 95 mm Max. bending cycles 2000000 According to UL 758/1581 (Cable Flame) according to UL 758/1581 FT1 Flame resistance According to DIN EN 60332-1-2 Resistance to oil according to DIN EN 60811-404, 168 h at 60 °C -40 °C ... 80 °C (cable, fixed installation)Ambient temperature (operation) -20 °C ... 80 °C (Cable, flexible installation) Environmental and real-life conditions Ambient conditions IP65Degree of protection IP67 Ambient temperature (operation) -25 °C ... 85 °C (Plug / socket) Standards and regulations Standard designation M12 connector Standards/specifications IEC 61076-2-111 1276567 https://www.phoenixcontact.com/us/products/1276567 May 28, 2024, 1:07 AM Page 6 (12)

M12 x 1 male plug, angled 1276567 https://www.phoenixcontact.com/us/products/1276567 May 28, 2024, 1:07 AM Page 7 (12)

Pin assignment M12 male connector, 4-pos. 1276567 https://www.phoenixcontact.com/us/products/1276567 May 28, 2024, 1:07 AM Page 8 (12)

To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/1276567  UL Listed Approval ID: E468743  cUL Listed Approval ID: E468743 cULus Listed 1276567 https://www.phoenixcontact.com/us/products/1276567 May 28, 2024, 1:07 AM Page 9 (12)

ECLASS-11.0 27060311 ECLASS-12.0 27060311 ECLASS-13.0 27060327 ETIM ETIM 8.0 EC001855 UNSPSC UNSPSC 21.0 26121600 1276567 https://www.phoenixcontact.com/us/products/1276567 May 28, 2024, 1:07 AM Page 10 (12)

Environmental product compliance EU RoHS Fulfills EU RoHS substance requirements Yes, No exemptions China RoHS EFUP-EEnvironment friendly use period (EFUP) No hazardous substances above the limits EU REACH SVHC REACH candidate substance (CAS No.) No substance above 0.1 wt% 1276567 https://www.phoenixcontact.com/us/products/1276567 May 28, 2024, 1:07 AM Page 11 (12)

https://www.phoenixcontact.com/us/products/1560251 M12 sealing cap for unoccupied M12 plugs of the sensor/actuator cable, flush- type plugs and I/O devices in the field SAC BIT M12-D16 - Tool 1200305 https://www.phoenixcontact.com/us/products/1200305 Nut for assembling sensor/actuator cables with M12 connector and M12 connectors for assembly, knurl diameter: 16 mm, for 4 mm hexagonal drive Phoenix Contact 2024 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA

586 Fulling Mill Road

Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com 1276567 https://www.phoenixcontact.com/us/products/1276567 May 28, 2024, 1:07 AM Page 12 (12)