125GMT10 HOLLAND | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 5

Technical content

Amphenol All rights reserved DS-60-1938 060820 v3 800-677-2288 | abs-go.com Power :: 10/10 and 15/15 Position GMT Fuse Panels The Amphenol 125GMT10/nrg125GMT10 and 125GMT15/nrg125GMT15 fuse panels are 125A dual-feed and provide 10/10 and 15/15 GMT fuse positions. Our 125GMT/nrg125GMT panels feature ±12/±24/±48V operating voltages to serve both legacy and “next-gen” network applications. Engineered into a standard 1RU footprint that support up to 20A GMT fuses in each position, providing ample capacity for distribution to a broad range of components. The panel is available in standard terminal block outputs or connectorized outputs. This platform provides front access to GMT fuses. Also featured are front LED indicators for power/fuse alarms, monitoring status, rear connections for form C relay alarms, and optional nrgSMART connections. Depending on the model, each of the 125A feeds provide power for up to 10 or 15 GMT output positions. Field replaceable GMT fuses are available from 18/100A to 20A. The panel supports universal voltages (±12VDC to ±48VDC). Primary Benefits

  • Universal voltage (±12VDC, ±24VDC and ±48VDC) enables standardization on a single part number for multiple voltages
  • Up to 20A fuses for distribution to a variety of network elements
  • UL and NEBS compliant to ensure industry- standard safety and functional requirements
  • Form C relay contacts provide reliable alarm connections
  • Integrated designation card holder for simple circuit identification
  • Fail alarm LEDs indicate fuse and power failures
  • Clear, flame-retardant polycarbonate cover (94V-0) protects input and output power connections and wiring from damage
  • Horizontal feed inputs and a choice of outputs: either staggered terminal blocks that facilitate waterfall cable management, or connectors that speed up installation and allow cables to exit straight back from the panel
  • Optional Individual Circuit Monitoring provides high accuracy, 100% passive monitoring
  • Collect voltage and current for both feed and output circuit
  • Collect temperature using optional nrgTEMP probes 125GMT10 Front View 125GMT10 Rear View

Amphenol All rights reserved DS-60-1938 060820 v3 800-677-2288 | abs-go.com

Applications

  • Wireless
  • Central office
  • Co-location
  • Remote sites
  • Secondary distribution

Ordering Information

GMT Fuse Panel Part Number 125A Dual-Feed, 10/10 Panel, Horizontal Inputs, Output Terminal Blocks 125GMT10 125A Dual-Feed, 10/10 Panel, Horizontal Inputs, Connectorized Outputs (Connectors purchased separately) 125GMT10-C 125A Dual-Feed, 15/15 Panel, Horizontal Inputs, Output Terminal Blocks 125GMT15 125A Dual-Feed, 15/15 Panel, Horizontal Inputs, Connectorized Outputs (Connectors purchased separately) 125GMT15-C nrgSMART Circuit Monitoring, Controller, 125A Dual-Feed, 10/10 Panel, Horizontal Inputs, Output Terminal Blocks nrg125GMT10-CTRL nrgSMART Circuit Monitoring, Sensor, 125A Dual-Feed, 10/10 Panel, Horizontal Inputs, Output Terminal Blocks nrg125GMT10-SENS nrgSMART Circuit Monitoring, Controller, 125A Dual-Feed, 10/10 Panel, Horizontal Inputs, Connectorized Outputs (Connectors purchased separately) nrg125GMT10-CTRL-C nrgSMART Circuit Monitoring, Sensor, 125A Dual-Feed, 10/10 Panel, Horizontal Inputs, Connectorized Outputs (Connectors purchased separately) nrg125GMT10-SENS-C nrgSMART Circuit Monitoring, Controller, 125A Dual-Feed, 15/15 Panel, Horizontal Inputs, Output Terminal Blocks nrg125GMT15-CTRL nrgSMART Circuit Monitoring, Sensor, 125A Dual-Feed, 15/15 Panel, Horizontal Inputs, Output Terminal Blocks nrg125GMT15-SENS nrgSMART Circuit Monitoring, Controller, 125A Dual-Feed, 15/15 Panel, Horizontal Inputs, Connectorized Outputs (Connectors purchased separately) nrg125GMT15-CTRL-C nrgSMART Circuit Monitoring, Sensor, 125A Dual-Feed, 15/15 Panel, Horizontal Inputs, Connectorized Outputs (Connectors purchased separately) nrg125GMT15-SENS-C 125A Dual-Feed, 10/10 Panel, Horizontal Inputs, Connectorized Outputs (Connectors purchased separately) 125GMT10-C 125A Dual-Feed, 15/15 Panel, Horizontal Inputs, Output Terminal Blocks 125GMT15 125A Dual-Feed, 15/15 Panel, Horizontal Inputs, Connectorized Outputs (Connectors purchased separately) 125GMT15-C nrgSMART Circuit Monitoring, Controller, 125A Dual-Feed, 10/10 Panel, Horizontal Inputs, Output Terminal Blocks nrg125GMT10-CTRL nrgSMART Circuit Monitoring, Sensor, 125A Dual-Feed, 10/10 Panel, Horizontal Inputs, Output Terminal Blocks nrg125GMT10-SENS nrgSMART Circuit Monitoring, Controller, 125A Dual-Feed, 10/10 Panel, Horizontal Inputs, Connectorized Outputs (Connectors purchased separately) nrg125GMT10-CTRL-C nrgSMART Circuit Monitoring, Sensor, 125A Dual-Feed, 10/10 Panel, Horizontal Inputs, Connectorized Outputs (Connectors purchased separately) nrg125GMT10-SENS-C Accessories (Purchased Separately) Part Number Tie Bar Kit: Connectorized, Rear Mount Tie Bar, Mounting Hardware 307653 nrgSMART Temperature Sensor, ACC, 6ft nrgTemp Replacement Components Part Number Replaceable Alarm Card 307608 Replaceable Alarm Card, nrgSMART 307710 125GMT15-C rear view

Amphenol All rights reserved DS-60-1938 060820 v3 800-677-2288 | abs-go.com Replaceable Controller Card, nrgSMART 400822 Replaceable Sensor Card, nrgSMART 307607 Dummy GMT fuse 132748 19” Mounting Bracket Kit: 2x 19” Brackets, Mounting Hardware PMTG19 23” Mounting Bracket Kit: 2x 23” Brackets, Mounting Hardware PMTG23 Replaceable Alarm Card 307608 Replaceable Alarm Card, nrgSMART 307710 Replaceable Controller Card, nrgSMART 400822 Replaceable Sensor Card, nrgSMART 307607 Dummy GMT fuse 132748 19” Mounting Bracket Kit: 2x 19” Brackets, Mounting Hardware PMTG19 23” Mounting Bracket Kit: 2x 23” Brackets, Mounting Hardware PMTG23 Connectors (Purchased Separately) Part Number P24 Connector Kit: GMT, 12-10 AWG, Plug, Retainer, 2x Contacts 150336 P24 Connector Kit: GMT, 14-12 AWG, Plug, Retainer, 2x Contacts 150342 P24 Connector 5 Pack: GMT, 12-10 AWG, Set of 5 Plug Kits 150336-5 P24 Connector 5 Pack: GMT, 14-12 AWG, Set of 5 Plug Kits 150342-5 P24 Replaceable Contact: GMT, 12-10 AWG, Single Contact 150343 P24 Replaceable Contact: GMT, 14-12 AWG, Single Contact 150344 Crimp Tool: 14-6 AWG, Daniels, M300BT 150793 Crimp Tool Locator: Universal, Daniels, UH2-5 150794 GMT Fuses Part Number 18/100A 130781 1/4A 100151 1/2A 004001 3/4A 004008 1A 100991 1-1/3A 004006 1-1/2A 004011 2A 004002 2-1/2A 130783 3A 004012 3-1/2A 130782 4A 004013 5A 004014 7-1/2A 004010 10A 004015 12A 102287 15A 102288 20A 127240 20A with cover 131340 Specifications Inputs: Specifications: Voltage range (nominal voltage) ±12VDC, ±24VDC and ±48VDC Max. input load rating Standard Versions: Connectorized Versions: 125A @ 65°C per panel 125A @ 55°C per panel (De-rated to 100A @ 65°C) Short circuit withstand rating 5000A Nominal power loss at full load Less than 45W per side @5,000W full load per side (125A x 48V); 125A @ 65°C per panel

Amphenol All rights reserved DS-60-1938 060820 v3 800-677-2288 | abs-go.com Percentage of full power dissipation at nominal voltage Less than 0.5% Max. input interrupt device 125% of panel rating (for 125A rated feeds) Horizontal input terminal studs (with Keps nuts and flat washers) for dual-hole compression lugs Two pairs of ¼-20 studs on 5/8" centers per terminal [max. lug width of .5" (12.7 mm)]. Torque bolts (using 7/16" or 12 mm socket) to 50 in/lb. (5.5 N•m), max. Input wire size #8 AWG to #1/0 AWG Grounding: Specifications: Earth GND terminal bolts (with spring washers and flat washers) for dual-hole compression lug Three sets of 1/4-20 threaded holes on 5/8" centers. [max. lug width of .5" (12.7 mm)]. Torque bolts (using 7/16" or 12 mm socket) to 50 in/lb. (5.5 N•m), max. Ground wire size #6 AWG to #1 AWG Outputs: Specifications: Output fuse 20A GMT Fuse Output load 14A continuous GMT fuse Minimum short circuit interrupt rating 5000A Optional (Standard Versions): Terminal blocks, single-hole compression lugs 20 or 30, #6-32 screws [max. lug width of .31" (7.9)]. Torque screw to 8 in/lb. (.9 N•m), max. Optional (Standard Versions): Output wire size, single-hole compression lug #22 AWG to #6 AWG Optional (-C Versions): Connectors (purchased separately) 20 or 30, P24 connector plugs, latching, safe touch Optional (-C Versions): Output wire size, connectors #14 AWG to #10 AWG GMT fuses Cooper Bussmann and Littelfuse Alarms: Specifications: Alarm relay contacts 2A @ 30 VDC; 0.6A @ 60 VDC Max. alarm card power rating @12V: 18mA (0.22W) @24V: 20mA (0.48W); @48V: 30mA (1.44W) Alarm wire size #24 AWG, typical (#26 to #20 AWG) Terminals Wire wrap or mates with TE Connectivity 3-640428-3 Dimensions: Specifications: Standard Versions Height: Depth: Width: Connectorized Versions Height: Depth: Width: 1.75" (44 mm) 13.9" (353 mm) 17" (432 mm) without brackets 19” and 23” brackets included with panel 1.75" (44 mm) 13.8" (350 mm) without tie bar 16.5" (419 mm) with tie bar 17" (432 mm) without brackets 19” and 23” brackets included with panel Tie bar not included with panel Cable-end connectors not included with panel Compliance: Specifications: UL Listed (-CTRL and -SENS versions pending NEBS Level 3 Voltage Sensor (nrgSMART model only): Specifications: Sensor accuracy -19.99 to +19.99:  0.3V -20V to -60V:  0.1V -20V to +60V:  0.1V Voltage measurement range -60V to +60 VDC Note:

  • Voltage measurement may be slightly different than at input terminal blocks due to the voltage drop within the panel
  • Sensors are factory calibrated and do not require user adjustment Current Sensor (nrgSMART model only):

Amphenol All rights reserved DS-60-1938 060820 v3 800-677-2288 | abs-go.com nrgOS minimum required version nrgOS 4.1.0 nrgNET communications protocol Proprietary serial protocol used to communicate between panels and controller nrgNETconnector Removable 5-pin connector with screw down terminals nrgNET connector functions negNET IN