Screw Terminal Mounting Hardware and Accessories Bracket Dimensions Note: All mounting brackets and clamps except Figure 4 are zinc plated. Figure 4 is a black nylon. When mounting capacitors there is no need to wrap capacitors with protective wrapping before installing mounting clamp. Dimensions in Inches Dimensions in Millimeters Figure Bracket A B C D E F A B C D E F Number Figure 1 Figure 2 Figure 3 Figure 4 CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 CDE VR mounting clamps may be used to mount any cylindrical capac - itor with a 1” to 3” diameter that is to be mounted in a vertical position. Ma- terial is 1010 CRS, commercial grade #4 temper ASI scale. Parts are finished with .0001 (nominal) zinc chromate plating. Use for mounting CG types, PSU, SF and MPF types. Material thick- ness is .035” Catalog Part Number Dimensions Diameter Unassembled Assembled of Part to be Without Screw & Nut with A B C Mounted Screw & Nut Included Screw & Nut 1" to 1-1/16 VR1B VR1 VR1A 1" 1-7/16" 1-7/8*" 2" to 2-1/16 VR8B VR8 VR8A 2" 2-1/2" 2-13/16" 2-1/2" to 2-9/16 VR10B VR10 VR10A 2-1/2" 3" 3-5/16" 3" to 3-1/8 VR12B VR12 VR12A 3" 3-7/16" 3-13/16" Screw VRSCREW — — 9/16" long 6-32 thread NC-2A Nut VRNUT — — Standard hex nut to fit screws VR1, 3 & 4 B Mtg .219” .375” .156”
2 Holes
.1561” Dia. .562” .750” VR6, 8,10 & 12 C ±0.01” 0.176” x 0.281” ±0.016 (3 places). B Mtng ±0.03” 0.344” ±0.016” 0.188” ±0.016” A ±0.016” 75 º 120 º ±3 º (3 Places) 0.375”±0.016” 1.125” ±0.016” 0.500” ±0.016” Footed Bracket VR Series Footed Bracket for types: 500C, 500R, 520C, 550C, 3186, 3188, 3191, 3198, 125, CGS, CGR, CGO, DCMC, HES Footed Bracket 125 Series RoHS Compliant All brackets and hardware are RoHS Compliant
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 Screw Terminal Mounting Hardware and Accessories Clamp Type Bracket Clamp Dimensions in Inches Number A B C D 125562-01 1.375 2.125 2.500 1.281 125562-05 1.750 2.500 2.875 1.656 125562-02 2.000 2.750 3.125 1.906 125562-04 2.500 3.250 3.625 2.406 125562-03 3.000 3.750 4.125 2.906 125562-06 3.500 4.250 4.625 3.481 Insulated Nuts for Stud Mounting Metal Plate/ Heat Sink (Reference only) Nylon Hex Nut For Stud Standoff Nut Nut Hex Mounting Nylon Nut Diameter Diameter Diameter Elevation Head Min. Hole Max. Chassis Max. Tightening Part Number (mm) S (mm) W (mm) T (mm) J (mm) Diameter Thickness Torque (mm) (mm) in. lbs. M8S17W25 M8 17 25 15 17 17.5 5 25 M12S22W30 M12 22 30 18 19 22.5 5 75 M12S30W38 M12 30 38 18 19 30.5 5 75 Clamp Dimensions
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830 • www.cde.com Capacitor Hardware Notice and Disclaimer: All product drawings, descriptions, specifications, statements, information and data (collectively, the “Information”) in this datasheet or other publication are subject to change. The customer is responsible for checking, confirming and verifying the extent to which the Information contained in this datasheet or other publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without any guarantee, warranty, representation or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on the knowledge that the Cornell Dubilier company providing such statements (“Cornell Dubilier”) has of operating conditions that such Cornell Dubilier company regards as typical for such applications, but are not intended to constitute any guarantee, warranty or representation regarding any such matter – and Cornell Dubilier specifically and expressly disclaims any guarantee, warranty or representation concerning the suitability for a specific customer application, use, storage, transportation, or operating environment. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by Cornell Dubilier with reference to the use of any Cornell Dubilier products is given gratis (unless otherwise specified by Cornell Dubilier), and Cornell Dubilier assumes no obligation or liability for the advice given or results obtained. Although Cornell Dubilier strives to apply the most stringent quality and safety standards regarding the design and manufacturing of its products, in light of the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies or other appropriate protective measures) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product-related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicated in such warnings, cautions and notes, or that other safety measures may not be required.