Technical content

Temperature Range –55 ºC to +125 ºC Rated Voltage Range 5 to 40 Vdc Capacitance Range 2600 µF to 190,000 µF Capacitance Tolerance –10 +75% Leakage Current ≤0.003 CV µA @ +25 ºC; ≤0.009 CV @ +125 ºC Ripple Current Multipliers Ambient Temperature EIA Ripple Life 5,000 h at full load @ 85 ºC per EIA IS-749 ∆ Capacitance ±20% ESR 200% of limit DCL 100% of limit Endurance Life Test 5,000 h at +125 ºC and rated voltage ∆ Capacitance ±20% ESR 200% of limit DCL 100% of limit Shelf Life Test 500 h @ 105 VC, capacitance, ESR and DCL, initial requirements Vibration 10 to 55 Hz, 0.06” and 10 g max, 1.5 h each of 2 axis RoHS Compliant Exceeding the requirements of military aluminum electrolytic large can capacitors, the Type 125 performs in the most demanding filter applications delivering the longest life and the lowest leakage in low- voltage, aluminum-electrolytic capacitors. It’s the choice for output capacitors in high temperature and military power supplies. Highlights - 5000 hour load life - Ripple Current to 50 amps - ESRs to 4mΩ - >90% capacitance at –40 ºC - Operates at +125 ºC Specifications Frequency 45 ºC 55 ºC 65 ºC 75 ºC 85 ºC 95 ºC 105 ºC CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 Type 125 –55 ºC to +125 ºC, Ultra-High Temperature, Military Grade The Pace-Setter for Long Life and High Temperature

50 Hz 60 Hz 120 Hz 360 Hz 1 kHz 5 kHz 10 kHz & Up

click here to see hardware and mounting options

CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 Part Numbering System Terminal Dimensions Type 125 –55 ºC to +125 ºC, Ultra-High Temperature, Military Grade The Pace-Setter for Long Life and High Temperature 125 333 U 7R5 AA 1 B Type Capacitance Tolerance Voltage Case Code Insulation Terminal 100 = 10 µF U = –10% +75% 6R3 = 6.3 Vdc See Ratings 0 = None A = Low Post 101 = 100 µF 063 = 63 Vdc Table 1 = Polyester B = High Post 100 = 100 Vdc Post Diameter H max Thread min Full Thread Torque Terminal Style Code in mm in mm in mm in∙lb N∙m Case Diam. (D) Length (L) Terminals (S) Inches mm Inches mm Inches mm oz g

CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 Type 125 –55 ºC to +125 ºC, Ultra-High Temperature, Military Grade The Pace-Setter for Long Life and High Temperature ESR Max Ripple Max ESR Max Ripple Max Catalog @ +25 ºC @ +85 ºC Nominal Catalog @ +25 ºC @ +85 ºC Nominal Cap Part Number 120 Hz 20 kHz 120 Hz 20 kHz Size D x L Cap Part Number 120 Hz 20 kHz 120 Hz 20 kHz Size D x L µF (Ω) (Arms) (Inches) µF (Ω) (Arms) (Inches) 5Vdc (8 Vdc Surge) 15Vdc (25 Vdc Surge) 110000 125114U005AJ1B 0.008 0.006 26.1 31.0 1 3/8 x 3 5/8 20Vdc (25 Vdc Surge) 89000 125893U6R3AJ1B 0.008 0.006 26.1 31.0 1 3/8 x 3 5/8 25Vdc (40 Vdc Surge) 78000 125783U7R5AJ1B 0.008 0.006 25.7 30.9 1 3/8 x 3 5/8 30Vdc (50 Vdc Surge) 51000 125513U12R5AJ1B 0.009 0.007 24.1 30.6 1 3/8 x 3 5/8 40Vdc (60 Vdc Surge) 15Vdc (25 Vdc Surge) 11000 125113U040AJ1B 0.011 0.007 20.0 28.3 1 3/8 x 3 5/8 40000 125403U015AJ1B 0.009 0.006 23.4 29.2 1 3/8 x 3 5/8

CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 Impedance vs. Frequency - 14,000 µF 7.5 Vdc Impedance (Ω) Impedance (Ω) Frequency (Hz)Frequency (Hz) 100 10k 100k1000 1M 10M 100 1000 10K 100K 1M 10M 0.001 0.01 0.1 1.0 0.001 0.01 0.1 1.0 Impedance vs. Frequency - 5700 µF 40 Vdc Type 125 Operating Life in Kilohours vs. Ripple Current Expedted Operating Life, kh 105 ºC 95 ºC 85 ºC 75 ºC 65 ºC 55 ºC 45 ºC 100 1000 Performance Curves Type 125 –55 ºC to +125 ºC, Ultra-High Temperature, Military Grade The Pace-Setter for Long Life and High Temperature

Notice and Disclaimer: All product drawings, descriptions, specifications, statements, information and data (collectively, the “Information”) in this datasheet or other publication are subject to change. The customer is responsible for checking, confirming and verifying the extent to which the Information con- tained in this datasheet or other publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without any guaran- tee, warranty, representation or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on the knowledge that the Cornell Dubilier company providing such statements (“Cornell Dubilier”) has of operating conditions that such Cornell Dubilier company regards as typical for such applications, but are not intended to constitute any guarantee, warranty or representa- tion regarding any such matter – and Cornell Dubilier specifically and expressly disclaims any guarantee, warranty or representation concerning the suitability for a specific customer application, use, storage, transportation, or operating environment. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by Cornell Dubilier with reference to the use of any Cornell Dubilier products is given gratis (unless otherwise specified by Cornell Dubilier), and Cornell Dubilier assumes no obligation or liability for the advice given or results obtained. Although Cornell Dubilier strives to apply the most stringent quality and safety standards regarding the design and manufacturing of its products, in light of the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies or other appropriate protective measures) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product-related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indi- cated in such warnings, cautions and notes, or that other safety measures may not be required.