1243299 PHOENIX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 12

Technical content

Please be informed that the data shown in this PDF document is generated from our online catalog. Please find the complete data in the user documentation. Our general terms of use for downloads are valid. Coupler connector, straight, for standard and SPEEDCON interlock, M17, number of positions: 7+PE, contact connection type: Socket, shielded: yes, degree of protection: IP67, cable diameter range: 5 mm ... 9.2 mm, number of positions: 8, connection method: Crimp connection, series: ST, Item is lead-free in accordance with RoHS II without Exemption 6c (Pb < 0.1 %) Your advantages Reduced size: ideal for compact devices• Consistent EMC protection for reliable connection solutions in the industrial environment Crimping connection: vibration- and temperature-resistant assembly Flexible use: reliably connect various cable diameters Commercial data Item number 1243299 Packing unit 1 pc Minimum order quantity 1 pc Product key ABRSEF GTIN 4063151400170 Weight per piece (including packing) 44.44 g Weight per piece (excluding packing) 44.44 g Country of origin DE ST-7ES1N8A9K03SX - Coupler connector 1243299 https://www.phoenixcontact.com/us/products/1243299 Jul 2, 2024, 7:15 AM Page 1 (12)

Order information: Order crimp contacts Ø 1 mm separately Safety note WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.

  • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
  • WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
  • The products are suitable for applications in plant, controller, and electrical device engineering.
  • When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
  • Assembled products may not be manipulated or improperly opened.
  • Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
  • When using the product in direct connection with third-party manufacturers, the user is responsible.
  • For operating voltages > 50 V AC, conductive connector housings must be grounded
  • Ensure that the protective or functional ground has been properly connected. are applicable when combining several circuits in a cable and/or connector
  • Only use tools recommended by Phoenix Contact
  • The installation notes/Design In documents online on the download page at phoenixcontact.com/products must be observed for this product.
  • Operate the connector only when it is fully plugged in and interlocked.
  • Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
  • Observe the minimum bending radius of the cable. Lay the cable without twisting it.
  • The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting Safety note ST-7ES1N8A9K03SX - Coupler connector 1243299 https://www.phoenixcontact.com/us/products/1243299 Jul 2, 2024, 7:15 AM Page 2 (12)

warnings (e.g. DIN EN ISO 13732-1:2008-12). Product properties Product type Circular connector (cable-side) Series ST Application Power Number of positions 8 Connection profile 7+PE Shielded yes Coding N Thread type M17 Material specifications Seal material FPM Housing material Metal Connection data Conductor connection Connection method Crimp connection Electrical properties Contact Contact diameter 1 mm Max. current 14 A Nominal voltage UN 630 V Overvoltage category III Degree of pollution 3 Rated surge voltage 6 kV Contact Contact diameter 1 mm Connector Type straight Direction of rotation Standard Connection 1 Head design Socket Cable/line External cable diameter 5 mm ... 9.2 mm Environmental and real-life conditions Ambient conditions ST-7ES1N8A9K03SX - Coupler connector 1243299 https://www.phoenixcontact.com/us/products/1243299 Jul 2, 2024, 7:15 AM Page 3 (12)

Ambient temperature (operation) -40 °C ... 125 °C Ambient temperature (storage/transport) 15 °C ... 25 °C Altitude 2000 m Permissible humidity (storage/transport) 50 % ... 65 % ST-7ES1N8A9K03SX - Coupler connector 1243299 https://www.phoenixcontact.com/us/products/1243299 Jul 2, 2024, 7:15 AM Page 4 (12)

0 10 20 30 40 50 60 70 80 90 100110 I [A]  [°C] = 3x1,0 + 2x0,5 mm 120130 I = current strength, ϑ = ambient temperature, 3x 14 A + 2x 2 A constant Schematic diagram Connector pin assignment ST-7ES1N8A9K03SX - Coupler connector 1243299 https://www.phoenixcontact.com/us/products/1243299 Jul 2, 2024, 7:15 AM Page 5 (12)

M17x1 Ø18,7 47,35□ Technical drawings can be found under Downloads ST-7ES1N8A9K03SX - Coupler connector 1243299 https://www.phoenixcontact.com/us/products/1243299 Jul 2, 2024, 7:15 AM Page 6 (12)

To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/1243299  cUL Recognized Approval ID: E335019-20111129 Nominal voltage UN Nominal current IN Cross section AWG Cross section mm2 Use group keine Power 600 V 5 A - - Signal 600 V 4 A - -  UL Recognized Approval ID: E335019-20111129 Nominal voltage UN Nominal current IN Cross section AWG Cross section mm2 Use group keine Power 600 V 5 A - - Signal 600 V 4 A - -  UL Recognized Approval ID: E153698-20140124 Nominal voltage UN Nominal current IN Cross section AWG Cross section mm2 Use group keine Power 600 V 5 A - - Signal 600 V 4 A - -  cUL Recognized Approval ID: E153698-20140124 Nominal voltage UN Nominal current IN Cross section AWG Cross section mm2 Use group keine Power 600 V 5 A - - Signal 600 V 4 A - - ST-7ES1N8A9K03SX - Coupler connector 1243299 https://www.phoenixcontact.com/us/products/1243299 Jul 2, 2024, 7:15 AM Page 7 (12)

ECLASS-11.0 27440103 ECLASS-12.0 27440103 ECLASS-13.0 27440103 ETIM ETIM 9.0 EC003570 ST-7ES1N8A9K03SX - Coupler connector 1243299 https://www.phoenixcontact.com/us/products/1243299 Jul 2, 2024, 7:15 AM Page 8 (12)

Environmental product compliance EU RoHS Fulfills EU RoHS substance requirements Yes, No exemptions China RoHS EFUP-EEnvironment friendly use period (EFUP) No hazardous substances above the limits EU REACH SVHC REACH candidate substance (CAS No.) No substance above 0.1 wt% ST-7ES1N8A9K03SX - Coupler connector 1243299 https://www.phoenixcontact.com/us/products/1243299 Jul 2, 2024, 7:15 AM Page 9 (12)

ST-10KS0,06-1,00 - Crimp contact 1243216 https://www.phoenixcontact.com/us/products/1243216 Crimp contact, Socket, turned, contact diameter: 1 mm, crimp range: 0.06 mm2 .. . 1 mm2, Item is lead-free in accordance with RoHS II without Exemption 6c (Pb < 0.1 %) ST-Z0016 - Color coding 1617993 https://www.phoenixcontact.com/us/products/1617993 Color coding, color: green ST-7ES1N8A9K03SX - Coupler connector 1243299 https://www.phoenixcontact.com/us/products/1243299 Jul 2, 2024, 7:15 AM Page 10 (12)

https://www.phoenixcontact.com/us/products/1618049 Color coding, color: orange ST-Z0018 - Color coding 1618050 https://www.phoenixcontact.com/us/products/1618050 Color coding, color: black ST-7ES1N8A9K03SX - Coupler connector 1243299 https://www.phoenixcontact.com/us/products/1243299 Jul 2, 2024, 7:15 AM Page 11 (12)

PROT-M17PRO-OT-IP20 - Plastic protective cap 1055708 https://www.phoenixcontact.com/us/products/1055708 Plastic protective cap, M17, degree of protection: IP20, series: M17 PRO Phoenix Contact 2024 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA

586 Fulling Mill Road

Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com ST-7ES1N8A9K03SX - Coupler connector 1243299 https://www.phoenixcontact.com/us/products/1243299 Jul 2, 2024, 7:15 AM Page 12 (12)