Please be informed that the data shown in this PDF document is generated from our online catalog. Please find the complete data in the user documentation. Our general terms of use for downloads are valid. Device connector front mounting, Range of articles: BPP, housing material: PPE, color: red/black, number of positions: 1, min. conductor cross section: 2.5 mm2, max. conductor cross section: 6 mm2, rated voltage: 1500 V DC, rated current: 26 A, Connection method: Crimp, Contact connection type: Pin Commercial data Item number 1231071 Packing unit 50 pc Minimum order quantity 50 pc Product key ABLDAB GTIN 4063151331542 Weight per piece (including packing) 8.128 g Weight per piece (excluding packing) 8.1 g Country of origin IN ES-FT-C4M-CO1 - Device connector front mounting 1231071 https://www.phoenixcontact.com/us/products/1231071 Jan 8, 2024, 6:56 AM Page 1 (9)

  • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
  • WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product. WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
  • The products are suitable for applications in plant, controller, and electrical device engineering.
  • Assembled products may not be manipulated or improperly opened.
  • Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
  • When using the product in direct connection with third-party manufacturers, the user is responsible.
  • For operating voltages > 50 V AC, conductive connector housings must be grounded
  • Ensure that the protective or functional ground has been properly connected.
  • Observe the corresponding technical data. You will find information: o On the product o On the packing label o In the supplied documentation o Online at phoenixcontact.com/products under the product
  • The installation notes/Design In documents online on the download page at phoenixcontact.com/products must be observed for this product.
  • Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
  • The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).
  • Operate the connector only when it is fully plugged in and interlocked.
  • Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards. Safety note ES-FT-C4M-CO1 - Device connector front mounting 1231071 https://www.phoenixcontact.com/us/products/1231071 Jan 8, 2024, 6:56 AM Page 2 (9)
  • Observe the minimum bending radius of the cable. Lay the cable without twisting it. Product properties Product type Connectors for energy storage Product family BPP Number of positions 1 Insulation characteristics Protection class II Degree of pollution 2 Electrical properties Rated voltage (III/2) 1500 V Nominal voltage ATD 1500 V DC in accordance with IEC 62852:2014/AMD1:2020 Rated surge voltage 16 kV Rated surge voltage (III/3) 16 kV Rated current (2.5 mm²) 26 A (in accordance with IEC 62852:2014/AMD1:2020) Rated current (4.0 mm²) 32 A (in accordance with IEC 62852:2014/AMD1:2020) Rated current (6.0 mm²) 38 A (in accordance with IEC 62852:2014/AMD1:2020) Contact resistance < 0.45 mΩ (depending on the mating connector used) Connection data Connection method Crimp Stripping length 8 mm Dimensions Width 21 mm Height 27.4 mm Length 49.2 mm Material specifications Color red/black Color of the housing part black Flammability rating according to UL 94 V0 Insulating material group I Seal material EPDM Material for screw connection PA Housing material PPE Cable/line Single wire, cross section 2.5 mm² 6 mm² Stripping length of the individual wire 9 mm -1 mm Halogen-free yes Mechanical properties ES-FT-C4M-CO1 - Device connector front mounting 1231071 https://www.phoenixcontact.com/us/products/1231071 Jan 8, 2024, 6:56 AM Page 3 (9)

Insertion/withdrawal cycles 100 Insertion force < 45 N ±10 N Environmental and real-life conditions Ambient conditions IP66 / IP68 (2m / 24h) (plugged in) IP20 (Not plugged in) Degree of protection IP66 / IP68 (2 m / 24 h) Ambient temperature (operation) -40 °C ... 85 °C Ambient temperature (assembly) -25 °C ... 50 °C Mounting Connection method Crimp ES-FT-C4M-CO1 - Device connector front mounting 1231071 https://www.phoenixcontact.com/us/products/1231071 Jan 8, 2024, 6:56 AM Page 4 (9)

ECLASS-11.0 27440109 ECLASS-12.0 27440109 ECLASS-13.0 27440109 ETIM ETIM 9.0 EC003569 UNSPSC UNSPSC 21.0 39121400 ES-FT-C4M-CO1 - Device connector front mounting 1231071 https://www.phoenixcontact.com/us/products/1231071 Jan 8, 2024, 6:56 AM Page 5 (9)

Environmental product compliance Environmentally friendly use period: unlimited = EFUP-eChina RoHS No hazardous substances above threshold values ES-FT-C4M-CO1 - Device connector front mounting 1231071 https://www.phoenixcontact.com/us/products/1231071 Jan 8, 2024, 6:56 AM Page 6 (9)

PV-FT-C-WALLMOUNT BK - Screw connection 1146092 https://www.phoenixcontact.com/us/products/1146092 Screw connection, Range of articles: Sunclix PV-C PROTECTION CAP - Protective cap 1785430 https://www.phoenixcontact.com/us/products/1785430 Protective cap, Range of articles: Sunclix, color: black. self-sealing, without interlock, set consisting of: 1 protective cap for connector side and 1 protective cap for coupling side ES-FT-C4M-CO1 - Device connector front mounting 1231071 https://www.phoenixcontact.com/us/products/1231071 Jan 8, 2024, 6:56 AM Page 7 (9)

PV-C3M-C-6-R3000 - Crimp contact 1050766 https://www.phoenixcontact.com/us/products/1050766 Crimp contact, Range of articles: Sunclix, color: silver, number of positions: 1, min. conductor cross section: 6 mm2, max. conductor cross section: 6 mm2, rated current: 40 A, Connection method: Crimp, Contact connection type: Pin. Crimping recommendation: Crimp the conductor with the crimp contact in accordance with IEC 60352 PV-C3M-C-2,5-4-R3000 - Crimp contact 1050768 https://www.phoenixcontact.com/us/products/1050768 Crimp contact, Range of articles: Sunclix, color: silver, number of positions: 1, min. conductor cross section: 2.5 mm2, max. conductor cross section: 4 mm2, rated current: 27 A, Connection method: Crimp, Contact connection type: Pin. Crimping recommendation: Crimp the conductor with the crimp contact in accordance with IEC 60352 ES-FT-C4M-CO1 - Device connector front mounting 1231071 https://www.phoenixcontact.com/us/products/1231071 Jan 8, 2024, 6:56 AM Page 8 (9)

CRIMPFOX-P SR 6 - Crimping pliers 1212755 https://www.phoenixcontact.com/us/products/1212755 Crimping pliers, for SUNCLIX solar crimp connectors 2.5 ... 6 mm2, unlockable pressure lock, precise parallel crimping, lateral entry, B crimp, incl. positioning tool Phoenix Contact 2024 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA

586 Fulling Mill Road

Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com ES-FT-C4M-CO1 - Device connector front mounting 1231071 https://www.phoenixcontact.com/us/products/1231071 Jan 8, 2024, 6:56 AM Page 9 (9)