1218B BELDEN | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 3
Technical content
Product: 1218B Audio Snake Cable, #22-6pr, TC, Indiv. Shielded Product Description Audio Snake Cable, 6-22 AWG tinned copper pairs, Datalene® insulation, individually shielded with Beldfoil® bonded to numbered/color-coded PVC jackets so both strip simulteaneously, flexible PVC jacket Technical Specifications Physical Characteristics (Overall) Conductor AWG Stranding Material Nominal Diameter No. of Pairs 22 7x30 TC - Tinned Copper 0.03 in 6 Conductor Count: 12 Total Number of Pairs: 6 Insulation Material Material Trade Name Nominal Diameter Nominal Wall Thickness PE - Polyethylene (Foam) Datalene® 0.06 in 0.015 in Color Chart Number Color
1 Brown
2 Red
3 Orange
4 Yellow
5 Green
6 Blue
Type Material Material Trade Name Coverage [%] Drainwire Material Drainwire Diameter Drainwire AWG Drainwire Construction n x D Tape Bi-Laminate (Alum+Poly) Beldfoil® 100% TC - Tinned Copper 0.030 in 22 7x30 Inner Jacket Material Nominal Diameter Nominal Wall Thickness PVC - Polyvinyl Chloride 0.153 in 0.015 in Outer Jacket Material Nominal Diameter Nominal Wall Thickness Ripcord PVC - Polyvinyl Chloride 0.578 in 0.055 in Yes
Electrical Characteristics
Individual Pair Nominal Shield DCR Nominal Conductor DCR Nominal Conductor DCR Conductor Resistance
10.6 Ohm/1000ft 15 Ohm/1000ft 15 Ohm/1000ft
Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Other Conductor to Shield
0.2 µH/ft Impedance Nominal Characteristic Impedance
70 Ohm
Nominal Velocity of Propagation (VP) [%] 78% Current Max. Recommended Current [A]
2 Amps per Conductor at 20ºC
Non-UL Voltage Rating Voltage Rating [V]
150 V RMS 300 V RMS
300 V RMS
Non-UL Temp Rating: 60°C Operating Temperature Range: -20°C To +60°C Mechanical Characteristics Bulk Cable Weight: 148 lbs/1000ft Max. Pull Tension: 164 lbs Min. Bend Radius/Minor Axis: 5.75 in Standards CPR Euroclass: Eca Applicable Environmental and Other Programs Environmental Space: Indoor (Not Riser or Plenum) EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/11/EC (BFR): Yes EU Directive 2011/65/EU (RoHS 2): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU (RoHS 2 amendment): Yes EU Directive Compliance: EU Directive 2003/11/EC (BFR) EU CE Mark: Yes MII Order #39 (China RoHS): Yes Suitability Suitability - Indoor: Yes Flammability, LS0H, Toxicity Testing IEC Flammability: IEC 60332-1-2 Plenum/Non-Plenum Plenum (Y/N): No Related Part Numbers Variants Item # Color Put-Up Type Length UPC 1218B B59500 Black, Matte Reel 500 ft 612825108993
1218B B591000 Black, Matte Reel 1,000 ft 612825108986 Footnote: C - CRATE REEL PUT-UP. Product Notes Notes: Datalene® insulation features include a low dielectric constant and a low dissipation factor for high-speed, low distortion data handling. Physical properties include good crush resistance and light weight. Pair jackets and shields are bonded so both strip simultaneously with automatic stripping equipment. History Update and Revision: Revision Number: 0.447 Revision Date: 12-19-2022 © 2023 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.