Advanced Diffused Batten, Dual Power, Tri-CCT Tri-colour selection Long life electronics LED lifetime >60,000 hours 8 years design life at max. ambient Increased ambient temperature of 40 degrees Increased lumen efficiency Exclusive 5 year warranty Microwave sensor Corridor mode
ORDERING INFORMATION
Description UMBRA ADVANCED 1200mm Diffused LED batten - Tri-CCT w sensor Driver Type Fixed output Item Code EV-UMBRA-ADV-DIFF-1200-S- TRI EFFICIENCIES Total System Efficiency 136 lm/W The performance of each component of a luminaire is demonstrated through its efficiencies, which together determine the total system efficiency of the product. The output of the LED chip is first multiplied by the optical and thermal efficiencies to calculate the Luminaire efficiency. However, this calculation does not consider the driver efficiency. To determine the overall efficiency of the system, the Luminaire efficiency must be multiplied by the driver efficiency, which accounts for all losses in the system. MECHANICAL Body Material Powder Coated Steel Diffuser Material PMMA Fitting Colour White Installation Type Surface mount IP Rating IP20 ELECTRICAL Electrical Rating Class I Input Current 0.2 A Input Frequency 50 Hz Input voltage 230Vac In Australia the Input voltage is defined as 230Vac -6%/+10%. This effectively means that the voltage range of these products are 216Vac - 253Vac or 240V +6% Maximum Wattage 36 W Power Factor 0.9 Standby Power 1 W Standby power for non-maintained/switched maintained emergency devices is measured when the light is off and the charger is in standby mode. For maintained emergency devices, standby power is measured when the light is on and the charger is in standby mode. Typically, charging occurs for the first 16 hours after the device is powered or after a battery discharge. Switch Type Inline Working Temp Range 0 to 40 °C LAMP Macadam Steps (SDCM) 4-step MacAdam Ellipse CCT Configuration TRI-CCT Colour Rendering Index (CRI) >80 Lamp/LED Current 890 mA Lamp/LED voltage 36 V 1300 438 658 sales@evolt.com.au ektor.com.au © 2025 Evolt Generated on 3rd of February 2025 06:15:28 - Page 1
LED Lifetime >60000 hrs This is the Reported LED Lifetime in Hours based on TM-21. Ektor does not list the projected or calculated LED lifetime, which is normally longer as TM-21 Addendum B explicitly states "The Calculated and Projected Lp(Dk) are not to be reported". This Lifetime refers to the life of a single LED however the system life is longer since the probability and binomial distribution of all LEDs in the system means that the average led is performing above the specification and compensates for the LEDs falling below. Ambient Temp (°C) 25 °C 40 °C L70B10 >60000 hrs >60000 hrs This rating defines the performance of the led within its lifetime. L relates to lumen depreciation, where the proceeding number gives the resultant lumen output at the end of it reported lifetime. L70, would mean 30% lumen depreciation which means 70% of its initial output and is tested accordingly to TM-21. The B part refers to failures, which can be define as the percentage of LEDs which fall below the L value in the projected lifetime. A value of B10 refers to 10% failure and a value of B50 refers to 50% failure. After the defined lifetime, the system will reach the defined lumen depreciation and the average led failures is defined by the B rating. The B rating is defined in and tested to IEC62717. TM-21 Test Hours 10000 hrs COLOUR TEMPERATURE
20 Watts
4000 K 3050 lm
5000 K 3150 lm
6500 K 3000 lm
36 Watts
4000 K 4700 lm
5000 K 4900 lm
6500 K 4700 lm
Driver Mode Constant Current Driver Type Fixed output Wiring Type Re-wireable terminal block (4 pin) PSTLM 0.09 Short Term Light Modulation (PstLM): The requirement is that PstLM should be less than or equal to 1.0. This metric measures the short-term flicker severity and ensures that flicker is not perceptible or is at a level that does not cause discomfort or health issues. SVM 0.012 Stroboscopic Visibility Measure (SVM): The requirement for SVM is that it should be less than or equal to 0.4. The SVM metric assesses the visibility of the stroboscopic effect, which can make moving objects appear to be stationary or moving in discrete steps, thus ensuring that this effect is minimized in lighting environments to prevent visual discomfort and safety hazards. SENSOR (S SUFFIX) Adjustable Detection Area / Sensitivity Yes Adjustable Hold Time Yes Adjustable Standby Level Yes Adjustable Standby Period Yes Corridor Function Yes Detection Range 10 m Dusk Mode Yes Lux Adjustment Yes Sensor Type Microwave Switched Output No Time Delay 5s-14mins ENERGY SAVINGS SCHEME Ipart Approval Yes REES Approval Yes VEU Approval Yes COMPLIANCE Product Design Life 8 years The product design life relates to the total product life which includes LEDs, drivers and the enclosure. This is different to the LED lifetime which only refers to the economical lifetime of the LEDs at which time the lumen output has dropped below the L Value. The product design life is calculated at the maximum ambient or working temperature of the product and takes into account the Daily Use. Daily Use 16 hrs The Daily Use is the recommended time required to meet the product's design life. Installations can exceed this time, however the product design life will be reduced proportionally. Standards AS/NZS 60598.1 AS/NZS 60598.2.1 AS/NZS 61347.1 AS/NZS 61347.2.13 AS CISPR 15 WARRANTY Commercial Use Warranty 5Y return to base on General lighting components First 2Y includes an exclusive onsite warranty VIP Warranty 2 Onsite, 3 RTB (Total 5 Years) VIP warranty is available to registered users and is subjected to additional terms and conditions. Warranty Operating Hours 25000 hrs This product is provided with a warranty up until the stated warranty period or until the stated warranty operating hours has been reached (whichever occurs first). Information is subject to change without prior notice. Images are for illustrative purposes only. E&OE Generated on 3rd of February 2025 06:15:28 - Page 2
EV/UMBRA/ADV/DIFF/1200 (Half Power / 5000K) EV/UMBRA/ADV/DIFF/1200 (Full Power / 6500K)EV/UMBRA/ADV/DIFF/1200 (Full Power / 5000K)EV/UMBRA/ADV/DIFF/1200 (Full Power / 4000K)EV/UMBRA/ADV/DIFF/1200 (Half Power / 6500K)EV/UMBRA/ADV/DIFF/1200 (Half Power / 4000K) Powered by TCPDF (www.tcpdf.org) Information is subject to change without prior notice. Images are for illustrative purposes only. E&OE Generated on 3rd of February 2025 06:15:28 - Page 3