MEASURING AUTOMATION LIGHT GRIDS
A B C D E F H I J K L M N O P Q R S T MLG25S-0275D10504 | MLG-2 Prime MEASURING AUTOMATION LIGHT GRIDS
2 AUTOMATION LIGHT GRIDS | SICK Online data sheet | 2016-01-21 14:25:24
Subject to change without notice
Ordering information
Type Part no. MLG25S-0275D10504 1215266 Other models and accessories www.sick.de/MLG-2_Prime Detailed technical data
Features
Technology Sender/receiver Minimum detectable object (MDO) 29 mm 1) 2) Beam separation 25 mm Number of beams ≥ 12 Detection height 275 mm Software features Q1: presence detection Q2 / IN: contamination warning Q3: Auto-define height classification Inverted: - Teach: Cross beam 1) MDO min. detectable object. 2) Depending on beam separation without cross beam setting. Performance Maximum range 7 m 1) Minimum range ≥ 0 mm Working range 5 m Response time ≥ 6 ms 2) 3) 1) No reserve for environmental issue and deterioration of the diode. 2) Without high speed. 3) With resistive load. Interfaces Connection type Male connector M12, 5-pin IO-Link ✔
MLG25S-0275D10504 | MLG-2 Prime MEASURING AUTOMATION LIGHT GRIDS 2016-01-21 14:25:24 | Online data sheet Subject to change without notice AUTOMATION LIGHT GRIDS | SICK 3 Data interface 3 x Q (IO-Link) Fieldbus, industrial network IO-Link Type of fieldbus integration Integrated in the device Mechanics/electronics Wave length 850 nm Supply voltage Vs DC 18 V ... 30 V 1) Power consumption sender ≥ 55.6 mA 2) Power consumption receiver ≥ 122.4 mA 2) Ripple < 5 Vpp Output current Imax. ≤ 100 mA Output load capacitive 100 nF Output load inductive 1 H Initialization time < 1 s Dimensions (W x H x D) 34 mm x 373.3 mm x 30.6 mm Housing material Aluminum Indication LED Enclosure rating IP 65, IP 67 Circuit protection UV connections, reverse polarity protected, Output Q short-circuit protected, Interference pulse suppression Weight ≥ 0.847 kg Front screen PMMA Option Nonexistent 1) Without load. 2) Without load with 24 V. Ambient data Protection class III EMC EN 60947-5-2 Ambient temperature Operation: –30 °C ... +55 °C Storage: –40 °C ... +70 °C Ambient light immunity Direct: 12,000 lx Indirect: 50,000 lx Vibration resistance Sinusoidal oscillation 10-150 Hz 5 g Shock load Continuous shocks 10 g, 16 ms, 1000 shocks Single shocks 15 g, 11 ms 3 per axle
A B C D E F H I J K L M N O P Q R S T MLG25S-0275D10504 | MLG-2 Prime MEASURING AUTOMATION LIGHT GRIDS
4 AUTOMATION LIGHT GRIDS | SICK Online data sheet | 2016-01-21 14:25:24
Subject to change without notice Dimensional drawing (Dimensions in mm (inch)) SenderSender 16.1 (0.63) 15 (.59) 15 (.59) Receiver Receiver 3 3 A A 1) Beam separation 5 mm 63,3 (2.49) Beam separation 10 mm 68,3 (2.69) Beam separation 25 mm 83,3 (3.28) Beam separation 50 mm 108,3 (4.26) 1) Distance: MLG edge - first beam M12; 5pol 216.2 (8.51) M12; 5pol 216.2 (8.51) ① Detection height (see optical performance) ② Beam separation (RM) ③ Status indicator: green, yellow, red LEDs
MLG25S-0275D10504 | MLG-2 Prime MEASURING AUTOMATION LIGHT GRIDS 2016-01-21 14:25:24 | Online data sheet Subject to change without notice AUTOMATION LIGHT GRIDS | SICK 5 Adjustments 24 (0.94) 35.5 (1.4) 17.3 (1.68) 59 (2.32) 3yel red grn 1 2 ① MLG-2 with switching outputs Q ② MLG-2 with analog outputs QA ③ Status indicator: green, yellow, red LEDs Connection type and diagram Connector M12, 5-pin, switching outputs Q nc M nc TEST brn wht blu blk gra M Q1/C brn wht blu blk gra Sender Receiver 1 2 5 34 1 2 5 3 ① Not assigned Recommended accessories Other models and accessories www.sick.de/MLG-2_Prime Brief description Type Part no. Modules and gateways
A B C D E F H I J K L M N O P Q R S T MLG25S-0275D10504 | MLG-2 Prime MEASURING AUTOMATION LIGHT GRIDS
6 AUTOMATION LIGHT GRIDS | SICK Online data sheet | 2016-01-21 14:25:24
Subject to change without notice Brief description Type Part no. IO-Link version V1.1, Port class 2, PIN 2, 4, 5 galvanically connected, Supply voltage 18 V DC ... 32 V DC (limit values, operation in short-circuit protected network max. 8 A) IOLP2ZZ-M3201 (SICK Memory Stick) 1064290 IO-Link V1.1 Class A port, USB2.0 port, optional external power supply 24V / 1A IOLA2US-01101 (SiLink2 Master) 1061790 EtherCAT IO-Link Master, IO-Link V1.1, power supply via 7/8'' cable 24 V / 8 A, fieldbus connection via M12 cable IOLG2EC-03208R01 (IO-Link Master) 6053254 EtherNet/IP IO-Link Master, IO-Link V1.1, power supply via 7/8'' cable 24 V / 8 A, field- bus connection via M12-cable IOLG2EI-03208R01 (IO-Link Master) 6053255 PROFINET IO-Link Master, IO-Link V1.1, Class A port, power supply via 7/8'' cable 24 V /
8 A, fieldbus connection via M12 cable
(IO-Link Master) 6053253 Plug connectors and cables Head A: female connector, M12, 5-pin, straight Head B: cable Cable: PVC, unshielded, 5 m DOL-1205-G05M 6009868
SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com