1212 BELDEN | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 3

Technical content

Product: 1212 Category 5E+ Cable, 4 Pair, U/UTP, CMR Product Description Category 5E+ Premise Horizontal Cable (350MHz), 4 Pair, 24 AWG Solid Bare Copper Conductors, U/UTP, Riser-CMR, PVC Jacket Technical Specifications Product Overview Suitable Applications: Premise Horizontal Cable, Ethernet 1000BASE-T, Ethernet 100BASE-TX, Ethernet 10BASE-T, PoE++, PoE+, PoE Patent: This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents. Construction Details Conductor Size Stranding Material Number of Pairs

24 AWG Solid BC - Bare Copper 4

PO - Polyolefin White/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown Outer Jacket Material Nom. Diameter Ripcord PVC - Polyvinyl Chloride 0.206 in (5.23 mm) Yes Overall Cable Diameter (Nominal): 0.206 in (5.23 mm)

Electrical Characteristics

Max. Conductor DCR Max. Capacitance Unbalance

89 Ohm/km (27 Ohm/1000ft) 330 pF/100m

Frequency Max. Delay Max. Delay Skew Nom. Velocity of Prop. 100 MHz 537.6 ns/100m 25 ns/100m 70% High Frequency Frequency [MHz] Max. Insertion Loss (Attenuation) Min. NEXT [dB] Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Max./Min. Input Impedance (unFitted) [Ohm] Max./Min. Fitted Impedance [Ohm]

300 V (CMR)

Mechanical Characteristics Temperature UL Temperature Operating Installation Storage 75°C -20°C To +75°C 0°C To +50°C -20°C To +75°C Bend Radius Stationary Min. Installation Min. 1.0 in (25 mm) 2.25 in (57.2 mm) Max. Pull Tension: 25 lbs (11 kg) Bulk Cable Weight: 20 lbs/1000ft Standards and Compliance Environmental Suitability: Riser, Indoor Sustainability: Product Lens™, Environmental Product Declaration (EPD) Available Flammability / Reaction to Fire: UL 1666 Riser, FT4, FT4, IEC 60332-1-2 CPR Compliance: CPR Euroclass: Eca; CPR UKCA Class: Eca NEC / UL Compliance: Article 800, CMR CEC / C(UL) Compliance: CMR ICEA Compliance: S-90-661 IEEE Compliance: IEEE 802.3bt Type 1, Type 2, Type 3 NEMA Compliance: NEMA WC-63.1 Data Category: Category 5e TIA/EIA Compliance: ANSI/TIA-568.2-D Category 5e Third Party Performance Verification: Category 5e ISO/IEC Compliance: ISO/IEC 11801-1, IEC 61156-5 European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16 UK Regulation Compliance: UKCA Mark APAC Compliance: China RoHS II (GB/T 26572-2011) Plenum Number: 1213 Product Notes Notes: Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Values above 350 MHz are for Engineering Information Only. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. History Update and Revision: Revision Number: 0.397 Revision Date: 11-09-2022 Part Numbers Variants Item # Color UPC 1212 010U1000 Black 612825061410 1212 0061000 Blue 612825061519 1212 0062500 Blue 612825061434

1212 006U1000 Blue 612825061427 1212 008U1000 Gray 612825061465 1212 005U1000 Green 612825061441 1212 003U1000 Orange 612825061458 1212 0091000 White 612825061489 1212 009U1000 White 612825061472 1212 0041000 Yellow 612825062189 1212 004U1000 Yellow 612825061496 © 2022 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.