Features

■ 100 kA max. discharge current rating ■ Multi-pole uni-block design ■ DIN Rail mountable ■ UL 60691 compliant integrated thermal disconnect ■ Visual fault indicator ■ Remote signalling capability ■ Compact design ideal for limited spaces ■ Standards compliance: ■ RoHS compliant*

1210 Series Heavy Duty AC Surge Protective Device

*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011. Specifi cations are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specifi c applications. The Bourns® Model 1210 Series is a heavy duty Surge Protective Device (SPD) designed to protect high risk electrical service entrance and branch panels. This SPD is intended to be installed at the front end of the installation, in the main switchboard, close to sensitive terminals or in installations without LPS (lightning rods). The Model 1210 Series is a single-pole module that can be confi gured for both common mode and differential mode protection in single and three phase applications up to 600 V.

Electrical Characteristics

Environmental Characteristics *RoHS COMPLIANT Characteristic Model No. 1210-xS-120 1210-xS-230 1210-xS-400 1210-xS-600 AC Network 120/240 V, 120/208 V 220/380 V, 240/415 V 220/380 V, 277/480 V, 347/600 V 480 V, 600 V Connection Mode 1-Pole, L-N or L-G AC System IT, TT, TN, Single, Split Phase, Delta, Wye Max. Operating Voltage (MCOV) 150 V 275 V 400 V 840 V TOV Withstand 150 V 275 V 400 V 840 V Leakage Current at Uc < 1 mA Follow Current None UL Nominal Discharge Current (In)

15 Impulses 8/20 µs 20 kA

Max. Discharge Current (I max)

1 Impulse 8/20 µs 100 kA

Max. Lightning Current (Iimp)

1 Impulse 10/350 µs --

UL Voltage Protection Rating (VPR) 600 V 900 V 1200 V 3000 V Protection Level (Up) 0.9 kV 1.25 kV 1.8 kV 4.0 kV UL Short-Circuit Current Rating (SCCR) 100kAIC Characteristic Model No. 1210-xS-120 1210-xS-230 1210-xS-400 1210-xS-600 Thermal Disconnector UL 60691 Overcurrent Protection Time Delay - 125 A Max. Connection By Screw Terminals, #6 AWG Max. Dimensions 90 x 18 x 67 mm / (3.543 x 0.709 x 2.638 In.) Mounting DIN Rail, 35 mm Symmetrical Remote Signal Indicator 250 V Max., 2 A Enclosure Material Thermoplastic UL 94V0 Characteristic Model No. 1210-xS-120 1210-xS-230 1210-xS-400 1210-xS-600 Operating Temperature -50 °C to +85 °C Operating Altitude 13,000 ft. (4,000 m) Relative Humidity 5 to 95 % Non-condensing, up to 100 % External Environmental Rating IP 20 Electrical DiagramGeneral Information Ft Ft V V L/N C 1.1 1.2 1.4 Mi V : High energy varistor Ft : Thermal fuse C : Remote signaling contact Mi : Disconnection indicator t° : Thermal disconnection system

Specifi cations are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specifi c applications. Product Dimensions and Schematics DIMENSIONS: MM (INCHES)

Applications

■ Electrical service entrance ■ Branch panels 67.0 (2.638) 10.6 (.417) 90.0 (3.543) 18.0 (.709) 1210-1S-xxx V L/N L/N AC Surge Protector SPD1210-xxx Uc In Imax Up Ft Mi C 36.0 (1.417) 1210-2S-xxx V L/N L AC Surge Protector SPD1210-xxx Uc In Imax Up N AC Surge Protector SPD1210-xxx Uc In Imax Up Ft Mi C V L/N Ft Mi 54.0 (2.126) 1210-3S-xxx V L/N L AC Surge Protector SPD1210-xxx Uc In Imax Up L AC Surge Protector SPD1210-xxx Uc In Imax Up Ft Mi C V L/N Ft Mi V L/N Ft Mi N AC Surge Protector SPD1210-xxx Uc In Imax Up 72.0 (2.835) 1210-4S-xxx V L/N L AC Surge Protector SPD1210-xxx Uc In Imax Up L AC Surge Protector SPD1210-xxx Uc In Imax Up Ft Mi C V L/N Ft Mi V L/N Ft Mi V L/N Ft Mi L AC Surge Protector SPD1210-xxx Uc In Imax Up N AC Surge Protector SPD1210-xxx Uc In Imax Up

Specifi cations are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specifi c applications. REV. 05/13 How To Order 1210 - x S - xxx Series Confi guration 1 = One Protected Pole 2 = Two Protected Poles 3 = Three Protected Poles 4 = Four Protected Poles Remote Signalling Code S = Remote Signalling Operating Voltage 120 = 120/240 V, 120/208 V 230 = 220/380 V, 240/415 V 400 = 220/380 V, 277/480 V, 347/600 V 600 = 480 V, 600 V Standards Compliance Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011 Asia-Pacifi c: Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116 Europe: Tel: +41-41 768 5555 • Fax: +41-41 768 5510 The Americas: Tel: +1-951 781-5500 • Fax: +1-951 781-5700 www.bourns.com