120NQ IRF | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 5
Technical content
Major Ratings and Characteristics Description/ Features IF(AV) Rectangular 120 A waveform VRRM range 35 to 45 V IFSM @ tp = 5 µs sine 29,000 A VF @ 120Apk, TJ=125°C 0.52 V TJ range - 55 to 150 °C Characteristics 120NQ.. Units The 120NQ...(R) high current Schottky rectifier module series has been optimized for very low forward voltage drop, with moderate leakage. The proprietary barrier technology allows for reliable operation up to 150° C junction temperature. Typical applications are in switching power supplies, convert- ers, free-wheeling diodes, and reverse battery protection. 150° C T J operation Unique high power, Half-Pak module Replaces two parallel DO-5's Easier to mount and lower profile than DO-5's High purity, high temperature epoxy encapsulation for enhanced mechanical strength and moisture resistance Very low forward voltage drop High frequency operation Guard ring for enhanced ruggedness and long term reliability SCHOTTKY RECTIFIER 120 Amp 120NQ...(R) SERIES Bulletin PD-2.224 rev. D 07/04 1www.irf.com Case Styles 120NQ...(R) D-67 IF(AV) = 120 A VR = 35 to 45V
120NQ...(R) Series Bulletin PD-2.224 rev. D 07/04 2 www.irf.com TJ Max. Junction Temperature Range -55 to 150 °C Tstg Max. Storage Temperature Range -55 to 150 °C RthJC Max. Thermal Resistance Junction 0.40 °C/W DC operation * See Fig. 4 to Case RthCS Typical Thermal Resistance, Case to 0.15 °C/W Mounting surface , smooth and greased Heatsink wt Approximate Weight 25.6 (0.9) g (oz.) T Mounting Torque Min. 17 (15) Non-lubricated threads Max. 29 (25) Terminal Torque Min. 23 (20) Max. 46 (40) Case Style HALF PAK Module Thermal-Mechanical Specifications Parameters 120NQ Units Conditions Kg-cm (Ibf-in) VFM Max. Forward Voltage Drop (1) 0.57 V @ 120A * See Fig. 1 0.73 V @ 240A
0.52 V @ 120A
0.69 V @ 240A
IRM Max. Reverse Leakage Current (1) 10 mA T J = 25 °C * See Fig. 2 500 mA T J = 125 °C VF(TO) Threshold Voltage 0.32 V T J = TJ max. rt Forward Slope Resistance 1.37 m Ω CT Max. Junction Capacitance 5200 pF V R = 5VDC, (test signal range 100Khz to 1Mhz) 25 °C LS Typical Series Inductance 7.0 nH From top of terminal hole to mounting plane dv/dt Max. Voltage Rate of Change 10000 V/ µs (Rated VR) TJ = 25 °C TJ = 125 °C VR = rated VR Parameters 120NQ Units Conditions (1) Pulse Width < 300µs, Duty Cycle < 2% Electrical Specifications IF(AV) Max. Average Forward Current 120 A 50% duty cycle @ T C = 106° C, rectangular wave form * See Fig. 5 IFSM Max. Peak One Cycle Non-Repetitive 29,000 5µs Sine or 3µs Rect. pulse Surge Current * See Fig. 7 1550 10ms Sine or 6ms Rect. pulse EAS Non-Repetitive Avalanche Energy 81 mJ T J = 25 °C, IAS = 12 Amps, L = 1.12 mH IAR Repetitive Avalanche Current 12 A Current decaying linearly to zero in 1 µsec Frequency limited by TJ max. VA = 1.5 x VR typical Parameters 120NQ Units Conditions Absolute Maximum Ratings A Following any rated load condition and with rated VRRM applied Part number 120NQ035(R) 120NQ040(R) 120NQ045(R) VR Max. DC Reverse Voltage (V) VRWM Max. Working Peak Reverse Voltage (V) 35 40 45 Voltage Ratings
120NQ...(R) Series Bulletin PD-2.224 rev. D 07/04 3www.irf.com Fig. 2 - Typical Values of Reverse Current Vs. Reverse Voltage Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics Fig. 1 - Maximum Forward Voltage Drop Characteristics 100 1000 Ins tantaneous F orward Curr ent - I (A) T = 150°C T = 125°C T = 25°C J J J F FM Forward Voltage Drop - V (V) 0.01 0.1 100 1000 10000 0 5 10 15 20 25 30 35 40 45 R R 125°C 100°C 75°C 50°C 25°C R evers e Current - I (mA) T = 150°CJ R evers e Voltage - V (V) 1000 10000 01 0 2 0 3 0 4 0 5 0 R TJunction Capacitance - C (pF ) R evers e Voltage - V (V) T = 25°CJ 0.001 0.01 0.1 thJC t , Rec ta ngular Pulse Duration (S econd s) S ingle Pulse (T hermal R esis tance) T hermal Impedance Z (°C/ W) D = 0.75 D = 0.50 D = 0.33 D = 0.25 D = 0.20 J DM thJC C Notes: 1. Duty factor D = t / t 2. Peak T = P x Z + T PDM 1 2
120NQ...(R) Series Bulletin PD-2.224 rev. D 07/04 4 www.irf.com Fig. 8 - Unclamped Inductive Test Circuit Fig. 5 - Maximum Allowable Case Temperature Vs. Average Forward Current Fig. 6 - Forward Power Loss Characteristics Fig. 7 - Maximum Non-Repetitive Surge Current FREE- WHEEL DIODE 40HF L40S02CU R R E NT MONIT OR HIGH-S PEED S WIT CHIRFP460 L DUT Rg = 25 o h m Vd = 25 Volt+ 1000 10000 100000 10 100 1000 10000 FSMNon-R epetitive S urge Current - I (A) pS quare Wave Pulse Duration - t (micros ec) At Any R ated L oad Condition And With R ated V Applied Following S urge RRM 100 110 120 130 140 150 160 0 2 04 06 08 0 1 0 0 1 2 0 1 4 0 1 6 0 1 8 0 DC Allowable Cas e T emperature - (°C) F( A V)Average F orward Current - I (A) se e no te ( 2) S quare wave (D = 0.50) 80% R ated V appliedR 100 0 2 04 06 08 0 1 0 0 1 2 0 1 4 0 1 6 0 1 8 0 DC Average P ower L os s - (Watts ) F( A V) RM S Lim it D = 0.20 D = 0.25 D = 0.33 D = 0.50 D = 0.75 Average F orward Current - I (A) (2) Formula used: TC = TJ - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6); PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = 80% rated VR
120NQ...(R) Series Bulletin PD-2.224 rev. D 07/04 5www.irf.com IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 07/04 Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level. Qualification Standards can be found on IR's Web site. Outline D-67 HALF PAK Module Dimensions in millimeters and (inches) Outline Table