080MS12AAMA1STD KEMET | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 7
Technical content
1© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4 041_MS_MD • 6/21/2021 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com Built Into Tomorrow Benefits
- Intermittent AC motor starting
- 6. 3 mm double amp tags (quick connect types)
- VD E approved to IEC 60252–2 Overview KEMET's MS/MD Series of aluminum electrolytic capacitors are designed for intermittent duty only and capable of withstanding the AC voltage applied to the motor during starting. The capacitor construction is comprised of either double anode or O-style (double anode and floating cathode) windings, which are housed in a molded plastic case. KEMET's MD Series is VDE approved to IEC 60252–2 for the defined ratings.
Applications
KEMET's MS/MD capacitors are a range of aluminium electrolytic capacitors specifically designed for AC operation which helps to start the motor by providing a leading current to the auxiliary winding. The capacitor is not permanently connected to the winding of the motor and is usually switched off automatically after starting. AC Motor Start Aluminum Electrolytic Capacitors MS/MD, +60°C/+70°C Part Number System
080 MS 12 AA M A 1 STD
(µF) Rating Rated Voltage (VAC) Size Code Manufacturing Style Capacitance Tolerance Terminal Code Version Example: 080 = 80 µF 120 = 120 µF MS = Motor start single rating MD = Motor start dual rating 12 = 120 22 = 220 26 = 260 See Dimension Table M = Molded case A = −0% +25% K = ±10% 1 = Double amp tag STD = Standard
2© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4 041_MS_MD • 6/21/2021 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com AC Motor Start Aluminum Electrolytic Capacitors – MS/MD, +60°C/+70°C Performance Characteristics Item Performance Characteristics Series MD (Dual voltage rating) MS (Single voltage rating) Capacitance Range 25 – 750 µF 25 – 750 µF Rated Voltage 120 – 360 VAC 50 Hz 120 – 260 VAC 50 Hz Operating Temperature −20°C to +70°C −20°C to +60°C Capacitance Tolerance ±10%, −0% +25% ±10%, −0% +25% Operational Lifetime 500 hours at +70°C, 1.1 VR (specified duty cycle) 500 hours at +60°C, 1.1 V R (specified duty cycle) Shelf Life 2 years 2 years Standards IEC 60252–2: AC Motor Capacitors - Part 2: Motor Start Capacitors VDE Approvals to IEC 60252–2 Rated Voltage 220 V 260 V Capacitor Type MD MD Capacitance (µF) (Note 1) (Note 2) 30 AA
40 AA AB AB
50 AA AB AB
60 AA AB AB
70 AB AB
80 AB AC AB
90 AC AC
100 AC AC
120 AC AC
125 AC AC
Note 1: Duty cycles approved 220 V at SD = 3 & ED = 1.7% 300 V at SD = 1 & ED = 0.1% Note 2: Duty cycles approved 260 V at SD = 3 and ED = 1.7% (40 – 125 µF) 330 v at SD = 1 and ED = 0.55% (40 – 125 µF) 360 v at SD = 1 and ED = 0.33% (90 – 125 µF) General approval notes:
- Valid for both ±10% and −0+25% tolerance.
- Valid for intermediate capacitance. Values in increments of 1 µF between 30 µF and 100 µF, and in increments of 5 µF between 100 µF and 125 µF.
- Approved duty cycles relate to 50 Hz, as per section 3.1.12.2 of IEC60252–2 operation at 60 Hz is also approved if the relative operation time is reduced by 20%. For example a 50 Hz duty cycle with ED = 1.7% is also approved for 60 Hz with ED = 1.36%.
3© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4 041_MS_MD • 6/21/2021 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com AC Motor Start Aluminum Electrolytic Capacitors – MS/MD, +60°C/+70°C Dimensions – Millimeters L Maximum SIDE VIEW TERMINAL END VIEW D Safety Vent D2 Size Code Dimensions in mm D D2 L ±0.5 ±0.5 Maximum AA 38 39 75 AB 38 39 90 AC 38 39 116 Power Factor The tangent of the loss angle for motor start capacitors shall not exceed 0.1 and shall be calculated as follows: Tan δ = W = true watts V x I apparent watts Duty Cycle The standard rating is 1.67% or 1/60th full time and corresponds to a maximum duty of 20 starts, each of three seconds duration per hour. It is expressed as 3/1.67 (a 3 minute cycle with 1.67% duration during which the capacitor may be energized). If the same capacitor is to be used for a duty cycle of 60 starts per hour the cycle duration will be 1 minute. The operation time per cycle will then have to be reduced to 1.67% of 1 minute (i.e. 1 second). Alternative duty cycles are available on request. Presence of Run Capacitor When the motor is fitted with both starting and run capacitors, consideration should be given to fitting of the appropriate discharge resistor to the starting capacitor. This is to protect the run capacitor from damage through discharge of the starting capacitor. Container Form Cylindrical mouldings, meeting creepage and clearance distances, according to IEC 60335–1 and flammability ratings according to UL94–V1.
4© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4 041_MS_MD • 6/21/2021 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com AC Motor Start Aluminum Electrolytic Capacitors – MS/MD, +60°C/+70°C Dimensions – Millimeters cont. Discharge Resistors A discharge resistor may be fitted to a motor start capacitor to prevent electrical overstress of the capacitor and/or for safety reasons. In accordance with IEC 60252, the resistor value should be such that it reduces the voltage on the capacitor, from the line voltage to less than 50 V within 60 seconds. The resistor value may be approximated as follows: R(kOhms) = T/Rated Capacitance (µF) Resistor Value (kOhms) Wattage 5.6 2W 15 2W 33 0.5W 56 1W 82 2W 100 1W AC Voltage T 120 50,000 220 32,000 260 30,000 280 28,000 330 26,000 Environmental Compliance All Part Numbers in this datasheet are Reach and RoHS compliant and Halogen-Free. As an environmentally conscious company, KEMET is working continuously with improvements concerning the environmental effects of both our capacitors and their production. In Europe (RoHS Directive) and in some other geographical areas such as China, legislation has been put in place to prevent the use of some hazardous materials, such as lead (Pb), in electronic equipment. All products in this catalog are produced to help our customers' obligations to guarantee their products and fulfill these legislative requirements. The only material of concern in our products has been lead (Pb), which has been removed from all designs to fulfill the requirement of containing less than 0.1% of lead in any homogeneous material. KEMET will closely follow any changes in legislation worldwide and make any necessary changes in its products, whenever needed. Some customer segments such as medical, military and automotive electronics may still require the use of lead in electrode coatings. To clarify the situation and distinguish products from each other, a special symbol is used on the packaging labels for RoHS compatible capacitors. Due to customer requirements, there may appear additional markings such as lead-free (LF), or lead-free wires (LFW) on the label.
5© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4 041_MS_MD • 6/21/2021 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com AC Motor Start Aluminum Electrolytic Capacitors – MS/MD, +60°C/+70°C Table 1A – Ratings & Part Number Reference VAC Rated Capacitance Capacitance Tolerance Case Size Duty Cycle Part Number Approval Minimum (µF) Maximum (µF) D x L (mm) 120 VRMS 150 VRMS VDE CQC 120 25 325 −0/+25% 38 x 75 1.67% (1)MS12AAMA1STD - - 120 25 360 ±10% 38 x 75 1.67% (1)MS12AAMK1STD - - 120 85 460 −0/+25% 38 x 90 1.67% (1)MS12ABMA1STD - - 120 90 510 ±10% 38 x 90 1.67% (1)MS12ABMK1STD - - 120 120 670 −0/+25% 38 x 116 1.67% (1)MS12ACMA1STD - - 120 130 750 ±10% 38 x 116 1.67% (1)MS12ACMK1STD - - 120 25 325 −0/+25% 38 x 75 1.67% 0.55% (1)MD12AAMA1STD - x 120 25 360 ±10% 38 x 75 1.67% 0.55% (1)MD12AAMK1STD - x 120 85 460 −0/+25% 38 x 90 1.67% 0.55% (1)MD12ABMA1STD - x 120 90 510 ±10% 38 x 90 1.67% 0.55% (1)MD12ABMK1STD - x 120 120 670 −0/+25% 38 x 116 1.67% 0.55% (1)MD12ACMA1STD - x 120 130 750 ±10% 38 x 116 1.67% 0.55% (1)MD12ACMK1STD - x VAC Rated Capacitance Capacitance Tolerance Case Size Duty Cycle Part Number VDE CQC (1) Insert capacitance code. Valid in increments of 1 μF between 30 μF and 100 μF, and in increments of 5 μF above 100 μF Table 1B – Ratings & Part Number Reference VAC Rated Capacitance Capacitance Tolerance Case Size Duty Cycle Part Number Approval Minimum (µF) Maximum (µF) D x L (mm) 220 VRMS 300 VRMS VDE CQC 220 30 65 −0/+25% 38 x 75 1.67% (1)MS22AAMA1STD - - 220 30 70 ±10% 38 x 75 1.67% (1)MS22AAMK1STD - - 220 40 90 −0/+25% 38 x 90 1.67% (1)MS22ABMA1STD - - 220 40 100 ±10% 38 x 90 1.67% (1)MS22ABMK1STD - - 220 55 140 −0/+25% 38 x 116 1.67% (1)MS22ACMA1STD - - 220 65 150 ±10% 38 x 116 1.67% (1)MS22ACMK1STD - - 220 30 60 −0/+25% 38 x 75 1.67% 0.10% (1)MD22AAMA1STD x x 220 30 60 ±10% 38 x 75 1.67% 0.10% (1)MD22AAMK1STD x x 220 40 80 −0/+25% 38 x 90 1.67% 0.10% (1)MD22ABMA1STD x x 220 40 80 ±10% 38 x 90 1.67% 0.10% (1)MD22ABMK1STD x x 220 80 125 −0/+25% 38 x 116 1.67% 0.10% (1)MD22ACMA1STD x x 220 80 125 ±10% 38 x 116 1.67% 0.10% (1)MD22ACMK1STD x x VAC Rated Capacitance Capacitance Tolerance Case Size Duty Cycle Part Number VDE CQC (1) Insert capacitance code. Valid in increments of 1 μF between 30 μF and 100 μF, and in increments of 5 μF above 100 μF Table 1C – Ratings & Part Number Reference VAC Rated Capacitance Capacitance Tolerance Case Size Duty Cycle Part Number Approval Minimum (µF) Maximum (µF) D x L (mm) 260 VRMS 330 VRMS 360 VRMS VDE CQC 260 25 55 −0/+25% 38 x 75 1.67% (1)MS26AAMA1STD - - 260 25 60 ±10% 38 x 75 1.67% (1)MS26AAMK1STD - - 260 35 75 −0/+25% 38 x 90 1.67% (1)MS26ABMA1STD - - 260 35 85 ±10% 38 x 90 1.67% (1)MS26ABMK1STD - - 260 50 110 −0/+25% 38 x 116 1.67% (1)MS26ACMA1STD - - 260 55 125 ±10% 38 x 116 1.67% (1)MS26ACMK1STD - - 260 25 50 −0/+25% 38 x 75 1.67% 0.55% (1)MD26AAMA1STD x x 260 25 55 ±10% 38 x 75 1.67% 0.55% (1)MD26AAMK1STD x x 260 40 80 −0/+25% 38 x 90 1.67% 0.55% (1)MD26ABMA1STD x x 260 40 80 ±10% 38 x 90 1.67% 0.55% (1)MD26ABMK1STD x x 260 90 125 −0/+25% 38 x 116 1.67% 0.55% 0.33% (1)MD26ACMA1STD x x 260 90 125 ±10% 38 x 116 1.67% 0.55% 0.33% (1)MD26ACMK1STD x x VAC Rated Capacitance Capacitance Tolerance Case Size Duty Cycle Part Number VDE CQC (1) Insert capacitance code. Valid in increments of 1 μF between 30 μF and 100 μF, and in increments of 5 μF above 100 μF
6© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4 041_MS_MD • 6/21/2021 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com AC Motor Start Aluminum Electrolytic Capacitors – MS/MD, +60°C/+70°C Marking KEMET LogoRated Capacitance, Capacitance Tolerance Rated Voltage (VAC) Climatic Category Part Number Code Made in China Date of Manufacture, Batch Number Construction Detailed Cross Section Margin Safety VentAmp Tag Terminal Laser Welded Terminal Tab Molded Plastic Case Safety Vent Molded Plastic Case Paper Spacer Impregnated with Electrolyte (First Layer) Paper Spacer Impregnated with Electrolyte (Third Layer) Laser Welded Terminal Tabs Deck Deck Safety Vent Plug Amp Tag Terminal Amp Tag Terminal Anode Aluminum Foil, Etched, Covered with Aluminum Oxide (Fourth Layer) Cathode Aluminum Foil, Etched (Second Layer)
7© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4 041_MS_MD • 6/21/2021 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com AC Motor Start Aluminum Electrolytic Capacitors – MS/MD, +60°C/+70°C KEMET Electronics Corporation Sales Offi ces For a complete list of our global sales offi ces, please visit www.kemet.com/sales. Disclaimer All product specifi cations, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such applications, but are not intended to constitute – and KEMET specifi cally disclaims – any warranty concerning suitability for a specifi c customer application or use. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not be required. KEMET is a registered trademark of KEMET Electronics Corporation.