1204100000 WEIDMULLER | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 5
Technical content
Creation date July 2, 2018 11:09:15 AM CEST Catalogue status 29.06.2018 / We reserve the right to make technical changes. 1 HDC insert HDC HE 10 FS Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com General ordering data Type HDC HE 10 FS Order No. 1204100000 Version HDC insert, Female, 500 V, 16 A, No. of poles: 10, Screw connection, Size: 4 GTIN (EAN) 4008190170172 Qty. 1 pc(s). For the screw connection, the wire connection level is designed as a screw element. All screw connections are equipped with a wire protection spring (with the exception of size 1). Number of poles: 10 Rated current: 16 A Rated voltage: 500 V Nominal voltage acc. to UL/CSA: 600 V AC/DC Screw connection
Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.comTechnical data Creation date July 2, 2018 11:09:15 AM CEST Catalogue status 29.06.2018 / We reserve the right to make technical changes. 2 Dimensions and weights Length 64 mm Length (inches) 2.52 inch Width 34 mm Width (inches) 1.339 inch Height 35.2 mm Height (inches) 1.386 inch Net weight 4 g Temperatures Limit temperature -40 °C ... 125 °C Dimensions Height of socket 35.2 mm Total length base 64 mm General data Conductor cross-section 2.5 mm² Insulating material PC glass-fibre reinforced (UL-listed and railway- certified) Insulating material group IIIa Insulation resistance 1010 Ω Material Copper alloy Max. torque for main contact 0.55 Nm Min. torque for main contact 0.5 Nm No. of poles 10 Plugging cycles, silver ≥ 500 Pollution severity 3 Rated current (DIN EN 61984) 16 A Rated impulse voltage (DIN EN 61984) 6 kV Rated voltage (DIN EN 61984) 500 V Rated voltage according to UL/CSA 600 V AC/DC Series HE Size 4 Surface finish Silver passivated Type Female UL 94 flammability rating V-0 Volume resistance ≤ 2mΩ Connection data PE Blade size, crosshead size PH1 Blade size, slotted (PE connection) SD 0.8 x 4.0 Connection type PE Screw connection Fixing screw M 4 Rated cross-section 4 mm² Stripping length PE connection 10 mm Tightening torque, max. PE connection 1.5 Nm Tightening torque, min. PE connection 1.2 Nm Wire connection cross section, finely stranded, max. 2.5 mm² Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. 2.5 mm² Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. 0.5 mm² Wire connection cross-section, finely stranded, min. 0.5 mm² Wire cross section, AWG (PE), max. AWG 12 Wire cross section, AWG (PE), min. AWG 20 Wire cross-section, solid, max. 2.5 mm² Wire cross-section, solid, min. 0.5 mm²
Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.comTechnical data Creation date July 2, 2018 11:09:15 AM CEST Catalogue status 29.06.2018 / We reserve the right to make technical changes. 3 Version Blade size size PZ0 Blade size, slotted (screw connection) SD 0.6 x 3.5 Clamping screw M 3 Conductor cross-section, max. 2.5 mm² Conductor cross-section, min. 0.5 mm² Material Copper alloy Max. torque for main contact 0.55 Nm Min. torque for main contact 0.5 Nm Size 4 Stripping length, rated connection 9 mm Surface finish Silver passivated Type of connection Screw connection Volume resistance ≤ 2mΩ Wire connection cross section AWG, max. AWG 14 Wire connection cross section AWG, min. AWG 20 Wire connection cross section, finely stranded, max. 2.5 mm² Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. 2.5 mm² Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. 0.5 mm² Wire connection cross-section, finely stranded, min. 0.5 mm² Wire cross-section, solid, max. 2.5 mm² Wire cross-section, solid, min. 0.5 mm² Classifications ETIM 3.0 EC001121 ETIM 4.0 EC000438 ETIM 5.0 EC000438 ETIM 6.0 EC000438 UNSPSC 30-21-18-01 eClass 5.1 27-14-34-19 eClass 6.2 27-26-12-04 eClass 7.1 27-44-02-05 eClass 8.1 27-44-02-05 eClass 9.0 27-44-02-05 eClass 9.1 27-44-02-05 Product information Descriptive text technical data Rated voltage 630 V / 6 kV at pollution degree 2 Descriptive text accessories Accessories, see chapter J - Tools, see chapter K Approvals Approvals ROHS Conform Downloads Brochure/Catalogue CAT 3 HDC 17/18 EN FL FIELDWIRING EN Engineering Data EPLAN, WSCAD, Zuken E3.S Technical Documentation 1204100000_HDC_HE_10_FS_STP_Blatt__1.pdf
Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.comDrawings Creation date July 2, 2018 11:09:15 AM CEST Catalogue status 29.06.2018 / We reserve the right to make technical changes. 4
A A.171çnç Technical data Tightening torques and screwing tools Screw size Connector type Dia. tightening torque in Nm Recommended blade inserts and AF size for hexagon socket M 2.5 Signal contacts S 6/6 0.5 - 0.55 SD 0.6 x 3.5 mm or PZ0 S 6/12 0.5 - 0.55 SD 0.6 x 3.5 mm or PZ0 M 2.9 x 0.5 Fastening screws HQ 4/2 0.8 (plastic) / 1.1 (metal) SD 0.6 x 3.5 mm or PH0 HQ 8 0.8 (plastic) / 1.1 (metal) SD 0.6 x 3.5 mm or PH0 HQ 17 0.8 (plastic) / 1.1 (metal) SD 0.6 x 3.5 mm or PH0 M 3 Contact screws HA 3 0.5 - 0.55 SD 0.5 x 3.0 mm HA 4 0.5 - 0.55 SD 0.5 x 3.0 mm HA 10 bis HA 48 0.5 - 0.55 SD 0.6 x 3.5 mm or PH0 HE 0.5 - 0.55 SD 0.6 x 3.5 mm or PZ0 HVE 0.5 - 0.55 SD 0.6 x 3.5 mm or PZ0 Signal contacts: S 4/2 0.5 - 0.55 SD 0.6 x 3.5 mm or PZ0 S 4/8 0.5 - 0.55 SD 0.6 x 3.5 mm or PZ0 PE connection via female contact S 4 0.5 - 0.8 SD 0.6 x 3.5 mm ConCept modular frame, metal 0.5 - 0.55 SD 0.6 x 3.5 mm PE terminal Fastening screws 0.5 - 0.55 SD 0.6 x 3.5 mm or PZ0 Guide pin 0.5 - 0.55 SD 0.6 x 3.5 mm or PZ0 Guide bush 0.5 - 0.55 SD 0.6 x 3.5 mm or PZ0 Coding pins 0.5 - 0.55 SD 0.6 x 3.5 mm or PZ0 M 4 Contact screws PE connection via male contact S 4 0.5 - 0.8 SD 0.6 x 3.5 mm ConCept modular frame, metal 1.2 - 1.5 SD 0.6 x 3.5 mm PE terminal S 6/6 (for signal contacts) 1.2 - 1.5 0.8 x 4 mm or PZ1 ConCept modular frame, plastic 1.2 - 1.5 0.8 x 4 mm or PZ1 M 5 PE terminal HSB 2 - 2.5 SD 1 x 5.5 mm or PZ2 S 4/0 (Screw connection) 2 - 2.5 SD 1.2 x 6.5 mm or PH2 S 4/0 (Axial screw connection) 2 - 2.5 SD 0.8 x 4 mm or PZ 2 S 4/2 2 - 2.5 SD 1.2 x 6.5 mm or PH2 S 4/8 2 - 2.5 SD 1.2 x 6.5 mm or PH2 S 6/12 2 - 2.5 SD 0.8 x 4 mm or PZ 2 S 6/36 2 - 2.5 SD 1.2 x 6.5 mm or PH2 S 8/24 2 - 2.5 SD 1.2 x 6.5 mm or PH2 S 12/2 2 - 2.5 SD 1.2 x 6.5 mm or PH2 M 6 Power contacts S 4/0 (Screw connection) 1.2 (1.5 mm²) / 2 (2.5 mm²) / 3 (4-16 mm²) SD 0.8 x 4 mm S 4/2 1.2 (1.5 mm²) / 2 (2.5 mm²) / 3 (4-16 mm²) SD 0.8 x 4 mm S 4/8 1.2 (1.5 mm²) / 2 (2.5 mm²) / 3 (4-16 mm²) SD 0.8 x 4 mm M 7 x 0.75 Power contacts S 4 1.1 – 1.7 SW 2 S 6/6 (+ PE) 6 – 8 SW 4 M 8 x 0.75 Power contacts S 6/12 1.1 – 1.7 SW 2 S 8/0 (+ PE) 6 (10-16 mm²) - 7 (25 mm²) SW 4 M10 x 1 Power contacts S 4/0 (Axial connection) 2 – 3 SW 3 Increasing the tightening torque does not improve the contact resistance. The stated torque settings offer optimal mechanical, thermal and electrical conditions. Exceeding the recommended values may even damage the conductor and terminal.