Features
- Holds 14 ATCA blades
- 14 slot full mesh backplane
- NEBS compliance tested: o Seismic zone 4 vibration profile per NEBS GR 63 o NEBS compliant for packaged Drop shock o NEBS compliant for Earthquake shock.
- Tested to meet FCC Class A conducted emissions
- Dual hot swap fan tray each with 6x 165 cfm fans
- Tested for 250W per slot cooling capability
- Dual Pigeon Point based Shelf manager
- Quad DC 70A PEM with integrated circuit breaker
- Power Interface Board (PIB) design to minimize wiring
- Removable NEBS compliant air filter
- Removable cable management bracket
- Front and rear ESD jacks
- Design optimized for volume manufacturing. Riveted construction
Description
13U-14Slot-ATCA-DC-Rev4 -031714 Environmental 11LA Order Information NUMBER OF SLOTS BP FABRIC ARCHITECTURE COOLING HEIGHT WIDTH PSU INPUT PSU OUTPUT SHELF MANAGER (Installed) REAR I/O Front View Side View RearView 14 = 14 slot E = 1 x SM F = 2 x SM (Bussed IPMB) G = 2 x SM (Radial IPMB) Z = Custom F = Star G = Dual Star H = Full Mesh J = Replicated Mesh Z = Custom A = 1 x Tray (plug in) B = 2 x Tray (plug in) C = 3 x Tray (plug in) Z = Custom C = 12U D = 13U E = 14U 8 = 84 T E = ETSI N = No Y = Yes DEPTH 3 = 300 - 399mm 4 = 400 - 499mm CARD ORIENTATION V = Vertical C = 90 - 230VAC (Fixed) G = 90 - 230VAC (Plug-in) H = 48VDC M = Dual 48VDC N = Quad 48VDC P = 90-230VAC(2 x HS, N+1) Q = 90-230VAC(3 x HS, N+1) X = No PSU B = 1200 - 1299 watts C = 1600 - 1799 watts D = 1800 - 1999 watts E = 2000 - 2199 watts F = 2200 - 2399 watts G = 2400 - 2599 watts H = 2600 - 2799 watts X = Not Installed B = 1 x Plug in D = 2 x Plug in X = Not Installed Instrumentation Instrumen- tation Operating Storage / Transit -20°C to +70°C 50,000 ft (15,240m) 5% to 95% Non condensing Temperature: 0°C to +50°C Altitude: 6000 ft (1,829m) Humidity: 5% to 95% Non condensing Shock NEBS packaged drop and earthquake shock test. The Earthquake shock was performed using GR 63-CORE Issue 3 BELLCORE Zone 4 Sec. 4.4. The package drop shock was performed using GR 63-CORE Issue 3 Sec. 4.3. Vibration: NEBS GR 63 seismic zone 4 vibration profile. The Office Vibration was performed using GR 63-CORE Issue 3 Sec. 4.4.4. Agencies Designed to meet UL 1950, FCC Class A or B, CE AdvancedTCA 14 Slot, 13U Chassis NEBS Compliant, Riveted Construction BP BARE BOARD