Energy Range 300 nJ to 1 J These sensors incorporate a diffuse metallic coating that enables measurements at high and low repetition rates across a wide range of energies, and wavelengths from 190 nm to 2.1 μm.

FEATURES

  • Unique diffuse metallic coating delivers increased damage threshold, allows high repetition rate operation and reduces specular reflectance
  • Operate over the entire 190 nm to 2.1 μm range
  • Enable pulse energy measurements from 300 nJ to 1 J with high signal-to- noise characteristics
  • Measure up to 10 kHz repetition rate
  • Direct USB and RS-232 interfaces –

APPLICATIONS

  • Medical
  • Scientific
  • Industrial
  • Laser Rep Rates up to 10 kHz

SPECIFICATIONS J-50MT-10KHZ-1571 J-50MT-10KHZ Energy Range 90 µJ to 100 mJ 400 µJ to 1 J Noise Equivalent Energy (μJ) <9 <40 Wavelength Range (μm) 0.19 to 2.1 Active Area Diameter (mm) 50 Max. Average Power 1 (W) 20 Max. Pulse Width (μs) 1.7 Max. Rep. Rate (pps) 10,000 Max. Energy Density (mJ/cm 2) 500 (at 1064 nm, 10 ns) Detector Coating Diffuse Metallic Diffuser No Calibration Wavelength (nm) 1064 Calibration Uncertainty (%) (k=2) ±2 Energy Linearity (%) ±3 Cable Length (m) 3 Cable Type USB and RS Part Number USB RS 1208286 1191447 1191433 SPECIFICATIONS J-25MT-10KHZ J-10MT-10KHZ Energy Range 90 µJ to 100 mJ 300 nJ to 200 µJ Noise Equivalent Energy <9 μJ <30 nJ Wavelength Range (μm) 0.19 to 2.1 Active Area Diameter (mm) 25 10 Max. Average Power 1 (W) 10 1 Max. Pulse Width (μs) 1.7 Max. Rep. Rate (pps) 10,000 Max. Energy Density (mJ/cm 2) 500 (at 1064 nm, 10 ns) 50 (at 1064 nm, 10 ns) Detector Coating Diffuse Metallic Diffuser No Calibration Wavelength (nm) 1064 Calibration Uncertainty (%) (k=2) ±2 Energy Linearity (%) ±3 Cable Length (m) 3 Cable Type USB and RS Part Number USB RS 1191446 1191445 High Repetition-Rate EnergyMax Sensors Datasheet 1 Extend average power range with optional heat sink.

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice. Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976. Coherent offers a limited warranty for all EnergyMax Sensors. For full details of this warranty coverage, please refer to the Service section at www.coherent.com or contact your local Sales or Service Representative. MC-020-21-0M0621 Copyright ©2021 Coherent, Inc. Coherent, Inc.,

5100 Patrick Henry Drive Santa Clara, CA 95054

p. (800) 527-3786 | (408) 764-4983 f. (408) 764-4646 tech.sales@coherent.com www.coherent.com High Repetition-Rate EnergyMax Sensors Datasheet MECHANICAL SPECIFICATIONS J-25MT-10KHZ J-10MT-10KHZ J-50MT-10KHZ & J-50MT-10KHZ-1571 Aperture Plate Ø 50.80 mm (2.0 in.) 16.54 mm (0.65 in.) Ø 25.25 mm (0.99 in.) 50.80 mm (2.0 in.) 76.20 mm (3.0 in.) Adjustable 200.15 mm (7.88 in.) Max. 117.60 mm (4.63 in.) Min. 2X 5.84 mm (0.23 in.) M6-6H THD X 5.08 mm (0.20 in.) and No. 1/4-20 UNC-2B THD X 5.08 mm (0.20 in.) for Mounting Sensor Note: Detector Surface is 3.81 mm (0.15 in.) Below Front Face of Aperture Plate Adjustable 189.99 mm (7.48 in.) Max. 107.44 mm (4.23 in.) Min. Aperture Plate Ø 40.64 mm (1.6 in.) Ø 10.5 mm (0.41 in.) 15.75 mm (0.62 in.) 50.80 mm (2.0 in.) 76.20 mm (3.0 in.) 2X 5.08 mm (0.2 in.) M4 X 17.78 mm (0.7 in.) THD X 4.57 mm (0.18 in.) and No. 8-32 UNC-2B THD X 6.35 mm (0.25 in.) for Mounting Sensor Note: Detector Surface is 3.81 mm (0.15 in.) Below Front Face of Aperture Plate Ø 76.20 mm (3.0 in.) 16.38 mm (0.65 in.) Ø 50.20 mm (1.98 in.) 50.80 mm (2.0 in.) 76.20 mm (3.0 in.) Adjustable 225.55 mm (8.88 in.) Max. 143.00 mm (5.63 in.) Min. 2X 5.08 mm (0.20 in.) M6-6H THD X 6.10 mm (0.24 in.) and No. 1/4-20 UNC-2B THD X 6.10 mm (0.24 in.) for Mounting Sensor Note: Detector Surface is 3.81 mm (0.15 in.) Below Front Face of Aperture Plate