1170-21-15A E-T-A | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 3

Technical content

Thermal Automotive Circuit Breaker 1170-... www.e-t-a.de1942

Description

Ordering information Technical data Compact single pole thermal circuit breaker with push-to-reset, tease free, trip free, snap action mechanism and separate (colour coded) manual release. Combining full feature circuit breaker protection and convenience with low cost of ownership benefits. Fitted with blade terminals for plug-in mounting. Type III to SAE J 553. Version 1176 is available especially for the automotive industry (current ratings correspond to those of blade fuses). Extra low voltage wiring systems on all types of vehicles and marine craft. 1170-... Standard current ratings, typical voltage drop values and actuator colours (manual release) Type No. 1170 plug-in Design standard 21 blade terminals for automotive fuse blocks (standard) with retaining clips, to DIN 72581, part 3 22 blade terminals for automotive fuse blocks, without retaining clips, to DIN 72581, part 3 Current ratings 3...25 A 1170 - 21 - 15 A ordering example Please be informed that we have minimum ordering quantities to be observed. Current rating (A) Voltage drop (mV) Actuator colour 3 < 300 violet 4 < 300 pink 5 < 300 light brown 6 < 150 mossy-green 7.5 < 150 brown 8 < 150 honey 10 < 150 red 15 < 150 blue 20 < 150 yellow 25 < 150 white Preferred types Standard current ratings (A) 3 4 5 6 7.5 8 10 15 20 25 1170-21- x x x x x x x x x x 1170-22- x x x x x x x x x x Preferred types For further details please see: www.e-t-a.de/ti_e Voltage rating (UN) DC 12 V / 24 V / 48 V Max. voltage (Usmax) DC 58 V Current ratings 3...25 A Typical life UN DC 24 V UN DC 24 V UN DC 24 V UN DC 48 V at rated current: 3...25 A 6 000 operations att 1 x I N 3...20 A 3 000 operations at 2 x I N

25 A 1 000 operations at 2 x I N

3...25 A 500 operations at 1 x IN Interrupting capacity Icn to ISO10924 Absolute breaking capacity to ISO 10924 ≥ 1 break operation at 2 000 A (L/R = 2,5 ms) Degree of protection (IEC 60529) operating area IP40 terminal area IP00 Vibration 10 g (57-500 Hz) ± 0.76 mm (10-57 Hz), to IEC 60068-2-6, test Fc, 10 frequency cycles/axis Shock 50 g (11 ms), to IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH to IEC 60068-2-78, test Cab Mass approx. 10 g IN 3...10 A 15 A 20 A 25 A UN DC 24 V 400 A (0-C0-C0) UN DC 48 V >100x at 75 A >100x at 100 A >100x at 135 A >10x at 200 A

Thermal Automotive Circuit Breaker 1170-... www.e-t-a.de 1942 The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section Technical information. Ambient temperature °F Ambient temperature °C -40 -40 -22 -30 -20 +14 -10 +32 +50 +10 Ambient temperature °F Ambient temperature °C +73.4 +23 +104 +40 +122 +50 +140 +60 +158 +70 +185 +85 Dimensions Internal connection diagram ON OFF7.238 3.40.6 6.4 18.8 16.6 5.6 5.2 14.5 4.2 3.6 7.6 0.8 3.1 max. 3.8 max. 9.8 .283 .134 ø.157 1.49 .024 6.4 .252 .220 .653 .740 .205 .571 .709 max. .386 .866 ø.118 .165 .142 .299 .031 .122 max. .149 1170-22 1170-21 1 10000 1000 100 0,1 0,4 0,8 12 46 81 02 04 0 Trip time in seconds ... times rated current 3...25 A + 23 °C + 85 °C - 40 °C Typical time/current characteristics at +23°C7+73.4°F This is a metric design and millimeter dimensions take precedence ( mm ) inch

Thermal Automotive Circuit Breaker 1170-... www.e-t-a.de1942 Thermal Automotive Circuit Breaker 1170-... Other sockets available to special order Labels: Weidmüller, D-33102 Paderborn terminal screw 6-32 UNC tightening torque max. 1.2 Nm blade terminal DIN 46244-A6.3-0.8 (QC .250) symmetrical hat rail EN 50022-35x7.5 Weidmüller style label (not supplied) 3.5 25.4 ø3.948 spring washer 32.6 12.7 1.00 1.29 1.69 1.85 2.28 .138.154 1.89 .500 symmetrical hat rail EN 50022-35x7.5 Weidmüller style label (not supplied) terminal screw 6-32 UNC tightening torque max. 1.2 Nm spring washer 3.5 25.4 32.6 ø3.9 12.7 1.00 1.29 1.69 1.85 2.28 .138.1541.89 .500 blade terminal DIN 46244-A6.3-0.8 (QC .250) symmetrical hat rail EN 50022-35x7.5 3.5 25.4 32.6 ø3.9 12.7 Weidmüller style label (not supplied)1.00 1.29 1.69 1.85 2.28 .138.154 1.89 .500 .512 .157 1.89 2.36 .276 Socket 12-P10 Socket 12-J20 Socket 12-A10 Dimensions for surface mounting Ordering information Mounting socket 12Accessories Accessories for mounting socket 12 Connector bus links -P10 X 210 588 01/ 1.5 mm2 (AWG 16), brown (up to 13 A max. load) X 210 588 02/ 2.5 mm2 (AWG 14), black (up to 20 A max. load) X 210 588 03/ 2.5 mm2 (AWG 14), red (up to 20 A max. load) X 210 588 04/ 2.5 mm2 (AWG 14), blue (up to 20 A max. load) 210 12.87 154.8 cylinder head screw ISO1207-M4x4 nickel plated washer A 4.3 DIN 125 nickel plated Phoenix terminal AKG 35 max.cross section 35 mm2 (AWG 2) fusible link 1.1mm (.043 in.) thick constriction) Cu rail, tin-plated.079.394 6.09 .504.276 Bus bar (supplied as a complete package) (up to 100 A max. load) X 211 157 01 with terminal X 211 157 02 without terminal~70 100 quick-connect tabs 6.3 (.250) DIN 46247 tinned brass, insulated ~2.76 Type No.

12 Mounting socket

P10 blade terminals A6.3-0.8 (QC .250) J20 screw terminals 6-32 UNC A10 1 blade terminal A6.3-0.8 (QC .250)/1 screw terminal 6-32 UNC Version (blank) single socket 20 two-way 30 three-way 40 four-way 60 six-way 12 - P10 - 20 ordering example This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted.