117 FLUKE | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 2
Technical content
Electrician’s Multimeter with Non-Contact Voltage Features include:
- VoltAlert™ technology for non-contact voltage detection
- AutoVolt automatic ac/dc voltage selection
- LoZ: helps prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- True-rms for accurate measurements on non-linear loads
- Measures 20 A (30 seconds momentary; 10 A continuous)
- Resistance, continuity, frequency and capacitance
- Min/Max/Average to record signal fluctuations
- Compatible with optional magnetic hanger (ToolPak™) for hands free operation
- CAT III 600 V safety rated Compact true-rms meter for commercial applications The Fluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The 117 includes integrated non-contact voltage detection to help get the job done faster. General specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 95 %. The accuracy specifications take the form of: ± ( [ % of reading ] + [ counts ] ) Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Fuse for A input 11 A, 1000 V FAST Fuse (Fluke PN 803293) Display Digital: 6,000 counts, updates 4/sec Bar graph 33 segments, updates 32/sec Operating temperature -10 °C to + 50 °C Storage temperature -40 °C to + 60 °C Battery 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery life 400 hours typical, without backlightN10140 R Actual size
2 Fluke Corporation 117 Electrician’s Multimeter with Non-Contact Voltage
PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke. ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 8/2006 Fluke. Keeping your world up and running. Measurement Range Resolution Accuracy ± ([% of reading] + [counts]) DC millivolts 600.0 mV 0.1 mV 2.0 % + 3 DC volts 6.000 V 0.001 V 60.00 V 0.01 V 600.0 V 0.1 V Auto volts 600.0 V 0.1 V 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) AC millivolts1 true-rms 600.0 mV 0.1 mV 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) AC volts1 true-rms 6.000 V 0.001 V 1.0 % + 3 (45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)60.00 V 0.01 V 600.0 V 0.1 V Continuity 600 Ω 1 Ω Beeper on < 20 Ω off > 250 Ω; detects opens or shorts of 500 µs or longer. Ohms 600.0 Ω 0.1Ω 0.9 % + 2 6.000 kΩ 0.001 kΩ 0.9 % + 1 60.00 kΩ 0.01 kΩ 600.0 kΩ 0.1 kΩ 6.000 MΩ 0.001 MΩ 40.00 MΩ 0.01 MΩ 1.5 % + 2 Diode test 2.000 V 0.001 V 0.9 % + 2 Capacitance 1000 nF 1 nF 1.9 % + 210.00 µF 0.01 µF 100.0 µF 0.1 µF 9999 µF 1 µF 100 µF to 1000 µF 1.9 % + 2 > 1000 µF 5 % + 20 Lo-Z capacitance 1 nF to 500 µF 10 % + 2 typical AC amps true-rms (45 Hz to 500 Hz) 6.000 A 0.001 A 1.5 % + 3 10.00 A 0.01 A 20 A continuous overload for 30 seconds max. DC amps 6.000 A 0.001 A 1.0 % + 3 10.00 A 0.01 A 20 A continuous overload for 30 seconds max. Hz (V or A input)2 99.99 Hz 0.01 Hz 0.1 % + 2 999.9 Hz 0.1 Hz 9.999 kHz 0.001 kHz 50.00 kHz 0.01 kHz Notes: 1 All ac voltage ranges are specified from 1 % to 100 % of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled. 2 Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. Ordering information Fluke-117 Electrician’s Multimeter with Non-Contact Voltage Included TL75 Test leads, holster, User’s manual and 9V battery (installed). ue