1124810000 WEIDMULLER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 7

Technical content

SVF 7.62HP/02/180SFI SN BK BX Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Product image Inverted male header with PUSH-IN connection technol- ogy for field wiring with inverted external flanges in 6 mm² with a 7.62 pitch. Also ideal as a touch-safe solution for inverse voltages. Meets the requirements of UL1059 600 V class C and IEC 61800-5-1. Optionally also available as screwable version and with- out flange. General ordering data Version PCB plug-in connector, male plug, 7.62 mm, Num- ber of poles: 2, 180°, PUSH IN without actuator, Tension-clamp connection, Clamping range, max. : 10 mm², Box Order No. 1124810000 Type SVF 7.62HP/02/180SFI SN BK BX GTIN (EAN) 4032248906970 Qty. 50 items Product data IEC: 1000 V / 57 A / 0.5 - 10 mm² UL: 600 V / 39 A / AWG 24 - AWG 10 Packaging Box Creation date 26.02.2026 05:03:42 MEZ Catalogue status / Drawings 1

SVF 7.62HP/02/180SFI SN BK BX Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Approvals Approvals ROHS Conform UL File Number Search UL Website Certificate No. (cURus) E60693 Dimensions and weights Depth 44.7 mm Depth (inches) 1.7598 inch Height 20.6 mm Height (inches) 0.811 inch Width 30.48 mm Width (inches) 1.2 inch Net weight 13.73 g Environmental Product Compliance RoHS Compliance Status Compliant without exemption REACH SVHC No SVHC above 0.1 wt% System Parameters Product family OMNIMATE Power - series BV/SV 7.62HP Type of connection Field connection Wire connection method PUSH IN without actuator, Tension-clamp connection Pitch in mm (P) 7.62 mm Pitch in inches (P) 0.300 " Conductor outlet direction 180° Number of poles 2 L1 in mm 7.62 mm L1 in inches 0.300 " Number of rows 1 Pin series quantity 1 Rated cross-section 6 mm² Touch-safe protection acc. to DIN VDE 57 106 Safe from finger touch Touch-safe protection acc. to DIN VDE 0470 IP20 plugged Protection degree IP20 Volume resistance 4.50 mΩ Can be coded Yes Stripping length 12 mm Tightening torque for screw flange, min. 0.2 Nm Tightening torque for screw flange, max.0.3 Nm Screwdriver blade 0.6 x 3.5 Plugging cycles 25 Material data Insulating material PA GF Colour black Colour chart (similar) RAL 9011 Insulating material group II Comparative Tracking Index (CTI) ≥ 500 Moisture Level (MSL) UL 94 flammability rating V-0 Contact material Cu-alloy Contact surface tinned Layer structure of plug contact 4...6 µm Sn glossy Storage temperature, min. -40 °C Storage temperature, max. 70 °C Operating temperature, min. -50 °C Operating temperature, max. 125 °C Temperature range, installation, min. -25 °C Temperature range, installation, max. 125 °C Conductors suitable for connection Clamping range, min. 0.5 mm² Clamping range, max. 10 mm² Solid, min. H05(07) V-U 0.5 mm² Solid, max. H05(07) V-U 6 mm² Stranded, min. H07V-R 10 mm² Creation date 26.02.2026 05:03:42 MEZ Catalogue status / Drawings 2

SVF 7.62HP/02/180SFI SN BK BX Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Stranded, max. H07V-R 10 mm² Flexible, min. H05(07) V-K 0.5 mm² Flexible, max. H05(07) V-K 10 mm² w. plastic collar ferrule, DIN 46228 pt 4, min. 1.5 mm² w. plastic collar ferrule, DIN 46228 pt 4, max. 6 mm² w. wire end ferrule, DIN 46228 pt 1, min. 1.5 mm² w. wire end ferrule, DIN 46228 pt 1, max. 6 mm² Clampable conductor Cross-section for conductor connection Type fine-wired nominal 2.5 mm² wire end ferrule Stripping length nominal 12 mm Recommended wire- end ferrule H2,5/12 Stripping length nominal 14 mm Recommended wire- end ferrule H2,5/19D BL Cross-section for conductor connection Type fine-wired nominal 4 mm² wire end ferrule Stripping length nominal 12 mm Recommended wire- end ferrule H4,0/12 Stripping length nominal 14 mm Recommended wire- end ferrule H4,0/20D GR Cross-section for conductor connection Type fine-wired nominal 6 mm² wire end ferrule Stripping length nominal 12 mm Recommended wire- end ferrule H6,0/12 Stripping length nominal 14 mm Recommended wire- end ferrule H6,0/20 SW Cross-section for conductor connection Type fine-wired nominal 1.5 mm² wire end ferrule Stripping length nominal 15 mm Recommended wire- end ferrule H1,5/18D SW Stripping length nominal 12 mm Recommended wire- end ferrule H1,5/12 Reference text The outside diameter of the plastic collar should not be larger than the pitch (P), Length of ferrules is to be chosen depending on the product and the rated voltage. Rated data acc. to IEC tested acc. to standard IEC 60664-1, IEC 61984 Rated current, min. number of poles (Tu=20°C) 57 A Rated current, max. number of poles (Tu=20°C) 50 A Rated current, min. number of poles (Tu=40°C) 57 A Rated current, max. number of poles (Tu=40°C)

45 A Rated voltage for surge voltage class /

Rated voltage for surge voltage class / pollution degree III/2

800 V Rated voltage for surge voltage class /

Rated impulse voltage for surge voltage class/ pollution degree II/2 6 kV Rated impulse voltage for surge voltage class/ pollution degree III/2 8 kV Rated impulse voltage for surge voltage class/ contamination degree III/3 8 kV Short-time withstand current resistance 3 x 1s with 420 A Creepage distance, min. 12.7 mm Clearance, min. 12.7 mm Creation date 26.02.2026 05:03:42 MEZ Catalogue status / Drawings 3

SVF 7.62HP/02/180SFI SN BK BX Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Rated data acc. to CSA Institute (CSA) CSA Certificate No. (CSA) 200039-1121690 Rated voltage (Use group B / CSA) 600 V Rated voltage (Use group C / CSA) 600 V Rated voltage (Use group D / CSA) 600 V Rated current (Use group B / CSA) 36 A Rated current (Use group C / CSA) 36 A Rated current (Use group D / CSA) 5 A Wire cross-section, AWG, min. AWG 24 Wire cross-section, AWG, max. AWG 10 Reference to approval values Specifications are maximum values, details - see approval certificate. Rated data acc. to UL 1059 Institute (cURus) CURUS Certificate No. (cURus) E60693 Rated voltage (Use group B / UL 1059) 600 V Rated voltage (Use group C / UL 1059) 600 V Rated voltage (Use group D / UL 1059) 600 V Rated current (Use group B / UL 1059) 39 A Rated current (Use group C / UL 1059) 39 A Rated current (Use group D / UL 1059) 5 A Wire cross-section, AWG, min. AWG 24 Wire cross-section, AWG, max. AWG 10 Reference to approval values Specifications are maximum values, details - see approval certificate. Packing Packaging Box VPE length 353.00 mm VPE width 137.00 mm VPE height 61.00 mm Type tests Test: Durability of markings Standard DIN EN 61984 section 7.3.2 / 09.02 taking pattern from DIN EN 60068-2-70 / 07.96 Test mark of origin, type identification, pitch Evaluation available Test durability Evaluation passed Test: Misengagement (Non- interchangeability) Standard DIN EN 61984 section 6.3 and 6.9.1 / 09.02, DIN EN 60512-13-5 / 11.08 Test 180° turned with coding elements Evaluation passed Test 180° turned without coding elements Evaluation passed Test: Clampable cross section Standard DIN EN 60999-1 section 7 and 9.1 / 12.00, DIN Conductor type Type of conductor and conductor cross- section solid 0.5 mm² Type of conductor and conductor cross- section stranded 0.5 mm² Type of conductor and conductor cross- section solid 6 mm² Type of conductor and conductor cross- section stranded 6 mm² Type of conductor and conductor cross- section AWG 24/1 Type of conductor and conductor cross- section AWG 24/19 Creation date 26.02.2026 05:03:42 MEZ Catalogue status / Drawings 4

SVF 7.62HP/02/180SFI SN BK BX Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Type of conductor and conductor cross- section AWG 14/1 Type of conductor and conductor cross- section AWG 14/19 Evaluation passed Test for damage to and accidental loosening of conductors Standard DIN EN 60999-1 section 9.4 / 12.00 Requirement 0.3 kg Conductor type Type of conductor and conductor cross- section H05V-U0.5 Type of conductor and conductor cross- section H05V-K0.5 Type of conductor and conductor cross- section AWG 20/1 Type of conductor and conductor cross- section AWG 20/19 Evaluation passed Requirement 1.4 kg Conductor type Type of conductor and conductor cross- section H07V-U6 Type of conductor and conductor cross- section H07V-K6 Type of conductor and conductor cross- section AWG 10/1 Type of conductor and conductor cross- section AWG 10/19 Evaluation passed Pull-out test Standard DIN EN 60999-1 section 9.5 / 12.00 Requirement ≥20 N Conductor type Type of conductor and conductor cross- section H05V-U0.5 Type of conductor and conductor cross- section H05V-K0.5 Type of conductor and conductor cross- section AWG 20/1 Type of conductor and conductor cross- section AWG 20/19 Evaluation passed Requirement ≥80 N Conductor type Type of conductor and conductor cross- section H07V-U6 Type of conductor and conductor cross- section H07V-K6 Type of conductor and conductor cross- section AWG 10/1 Type of conductor and conductor cross- section AWG 10/19 Creation date 26.02.2026 05:03:42 MEZ Catalogue status / Drawings 5

SVF 7.62HP/02/180SFI SN BK BX Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Evaluation passed Important note IPC conformity Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 "Class 2". Further claims on the products can be evaluated on request. Notes • Additional variants on request

  • Rated current related to rated cross-section & min. No. of poles.
  • Wire end ferrule without plastic collar to DIN 46228/1
  • Wire end ferrule with plastic collar to DIN 46228/4
  • P on drawing = pitch
  • Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards.
  • In accordance with IEC 61984, OMNIMATE-connectors are connectors without breaking capacity (COC). During designated use, connectors are not allowed to be engaged or disengaged when live or under load
  • Long term storage of the product with average temperature of 50 °C and maximum humidity 70%, 36 months Classifications ETIM 8.0 EC002638 ETIM 9.0 EC002638 ETIM 10.0 EC002638 ECLASS 14.0 27-46-02-02 ECLASS 15.0 27-46-02-02 Creation date 26.02.2026 05:03:42 MEZ Catalogue status / Drawings 6

SVF 7.62HP/02/180SFI SN BK BX Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Drawings Product image Dimensional drawing Graph Graph Creation date 26.02.2026 05:03:42 MEZ Catalogue status / Drawings 7