1120-F150-P1T1-WB0000-10A E-T-A | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 4
Technical content
www.e-t-a.de 2 - 31 Thermal Circuit Breaker 1120
Description
Ordering information
Illumination voltage/power consumption Technical data Double pole combined circuit breaker and ON/OFF switch with rocker actuation. Specially suited to single-phase applications. Snap-in front panel mounting. Thermal positively trip free mechanism ensures reliable overcurrent protection and safe physical isolation of the load circuit. Attractively styled, with rocker illumination optional. The status of the switching contacts is shown by the position of the rocker actuator. For high volume requirements customer-specific designs can be offered for the front bezel and the rocker. It meets the requirements of the CBE standard EN 60934 (IEC 60934): S type, TO. Meets the requirements regarding fire resistance of EN 60335-1 : 2007-02 Safety of household and similar electrical appliances. Minimum ordering quantities apply! Electrical motors, household appliances, office equiment, garden and hobby tools, power supplies, charging rectifiers, cable extension reels, multiple socket outlets. Voltage rating AC 240 V; DC 32 V DC 50 V (only double pole) Current ratings 3...16 A Typical life 10,000 operations at I N, inductive Ambient temperature -20 °C...+60 °C Insulation co-ordination (IEC 60664-1) 2.5 kV/2 reinforced insulation in operating area Dielectric strength operating area test voltage AC 3,000 V terminal area test voltage AC 1,500 V pole/pole test voltage AC 1,500 V Insulation resistance > 100 MΩ (DC 500 V) Switching capacity I cn AC 240 V: 200 A, 1 and 2 pole DC 50 V: 200 A, 2 pole DC 32 V: 200 A, 1 and 2 pole Switching capacity AC 277 V: 3,500 A, 1 and 2 pole (UL 1077) DC 50 V: 2,000 A, 2 pole DC 32 V: 2,000 A, 1 and 2 pole Degree of protection (IEC 60529) operating area IP40 with water splash protection IP66 terminal area IP00 Vibration 8 g (57-500 Hz), ± 0.61 mm (10-57 Hz) test to IEC 60068-2-6, test Fc, 10 frequency cycles/axis Shock 20 g (11 ms) test to IEC 60068-2-27, test Ea Corrosion 48 hrs in 5% salt mist, test to IEC 60068-2-11,test Ka Humidity 96 hrs in 95% RH, test to IEC 60068-2-3, test Cab Mass approx. 20 g Type No. 1120 thermal circuit breaker Configuration F snap-in panel mounting Size of frame 1 panel thickness 1 - 2.5 mm (without water splash protection) 2 panel thickness 1 - 2 mm (with water splash protection) Number of poles 5 double pole, one pole thermally protected Design 0 standard 1 with water splash protection Terminal design P 1 blade terminals 6.3x0.8 P2 blade terminals 6.3x0.8, 90° angled Characteristic curve T1 thermal Actuator style W rocker (latching switch) Actuator colour A black opaque B white opaque C red translucent D green translucent other colours upon request Actuator markings 0 0 „I“ and „O“ moulded in Illumination 0 without illumination B filament bulb Illumination voltage range 0 without illumination
3 AC 90 V - 140 V
4 AC 185 V - 275 V
3...16 A 1120 - F 1 5 0 - P1 T1 - W B 00 0 0 - 10 A ordering example 1120-.. without water splash protection with water splash protection operating voltage filament/neon AC 115 V < 1.5 mA AC 230 V < 1.5 mA Current rating (A) Internal resistance (Ω) Current rating (A) Internal resistance (Ω) 3 0.09 10 ≤ 0.02 4 0.05 12 ≤ 0.02 5 0.04 14 ≤ 0.02 6 0.03 15 ≤ 0.02 8 ≤ 0.02 16 ≤ 0.02 Standard current ratings and typical internal resistance values
www.e-t-a.de2 - 32 Thermal Circuit Breaker 1120 Dimensions single pole 1120-F1.0-P1.. 1120-F2.1-P1.. 36.4 9.5 9.5 28.5 11.3 33.3 2.9
9.5 OFF
blade terminals 6.3x0.8 to EN 60934 10.2 15.5 2.5±0.2 11.9 46.2 33.4 24.7 15.8 1.43 1.57 .114 .374 OFF 1.31.445 .374 .374 1.12 .401 .748 .610 .098±.008 1.82 .4691.31 .972 Dimensions double pole 1120-F...-P2 28.5 9.5 9.5 Please provide opposite support when fitting the cable lug. blade terminals 6.3x0.8 to EN 60934 with locating pin 2.5±0.2 7.8 min. Applicable for nominal dimensions without direct tolerance indication: DIN ISO 286 ± IT13 90°+6° .374 .374 1.12 .079 .098±.008 .307 min. Installation drawing operating area mounting area 1.5 1.5 22 12 21 11 .197 .197 .060 .060 .197 .197 .394 .595 .984 When installing the circuit breaker apply pressure on bezel only Approvals This is a metric design and millimeter dimensions take precedence ( mm ) inch Authority Voltage ratings Current ratings VDE (EN 60934) AC 240 V, DC 32 V DC 50 V 3...16 A 1- + 2-pole 3...16 A 2-pole UL, CSA AC 277 V, DC 32 V DC 50 V 3...16 A 1- + 2-pole 3...16 A 2-pole CCC AC 240 V, DC 32 V DC 50 V 3...16 A 1- + 2-pole 3...16 A 2-pole
www.e-t-a.de 2 - 33 Thermal Circuit Breaker 1120 The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. Ambient temperature °F -20 +14 -10 +32 +73.4 +23 +104 +40 +122 +50 +140 +60 All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. This is a metric design and millimeter dimensions take precedence ( mm ) inch Internal connection diagrams AC 240 V, DC 50 V double pole one pole thermally protected line 2111 12 22 load line 2111 12 22 load single pole connection AC 240 V, DC 32 V T1 - thermal characteristic curve 12 4 6 8 10 20 40 ... times rated current Trip time in seconds 10000 1000 100 0,1 23 °C 60 °C -20 °C 3...6 A 8...16 A 0,8 12 4 6 8 10 20 40 ... times rated current Trip time in seconds 10000 1000 100 0,1 0,8 continuous load: 100 % overload: 150 % continuous load: 100 % overload: 140 % 23 °C 60 °C -20 °C Cut-out dimensions version dimension “a” Applicable for nominal dimensions without direct tolerance indication: DIN ISO 286 ± IT13 36.7±0.1 ISO 13715 1.44±.004 16.1±0.1 max. R0. 3 a .634±.004 .039-.098 max. R0. .118 -0.4 -0.2 -.016 -.008 ±0.05 ±.002
www.e-t-a.de2 - 34 2013/14