DT80-311111 SICK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 10

Technical content

MID RANGE DISTANCE SENSORS

A B C D E F H I J K L M N O P Q R S T DT80-311111 | Dx80 MID RANGE DISTANCE SENSORS

Ordering information

Type Part no. DT80-311111 1118113 Other models and accessories www.sick.com/Dx80 Detailed technical data Mechanics/electronics Supply voltage Vs 12 V ... 30 V 1) 2) Ripple ≤ 5 Vpp 3) Power consumption ≤ 2 W 4) Initialization time 1,100 ms Warm-up time ≤ 1 min Housing material Metal (zinc diecast) Window material Plastic (PMMA) Connection type Cable with male connector, M12, 5-pin, 300 mm Indication 4 x LED, Full color LCD display Weight 280 g Dimensions (W x H x D) 33 mm x 65 mm x 57.04 mm Enclosure rating IP65, IP67 Protection class III 1) Limit values, reverse-polarity protected. Short circuit-protected mains operation: max. 5 A at 30 V DC. 2) When using IO-Link output Vs > 18 V. When using analog voltage output Vs > 13 V. 3) May not fall short of or exceed VS tolerances. 4) At ambient temperature ≥ 0 °C. Safety-related parameters MTTFD 101 years

2 LASER DISTANCE SENSORS | SICK Product data sheet | 2024-04-23 09:56:20

Subject to change without notice

DT80-311111 | Dx80 MID RANGE DISTANCE SENSORS Performance remission factor, 6% remission factor 1) 2) Target Natural objects Resolution 0.1 mm Repeatability ≥ 0.2 mm 3) 4) 5) Accuracy ± 2 mm 5) 6) Response time 33 ms ... 68 ms 7) Output time 33 ms, 50 ms, 100 ms, 200 ms ... 3000 ms 8) Light source Laser, red 9) Laser class 2 (IEC 60825-1:2014, EN 60825-1:2014+A11:2021) Typ. light spot size (distance) 7 mm x 7 mm (10 m) Average laser service life (at 25 °C) 100,000 h 1) 3000 ms measurement cycle time. 2) At the maximum permissible ambient temperature, the maximum measuring range may be reduced by up to 40%. 3) See diagrams for repeatability. 4) Equivalent to 1 σ. 5) 6% ... 90% remission factor. 6) Typical temperature drift: 0.05 mm/K. 7) Dependent on remission and measuring cycle time. 8) Continuously changing data output. 9) Wavelength: 655 nm, max. average power: < 1 mW, pulse length: > 400 ps. Interfaces IO-Link ✔, IO-Link V1.1, COM3 (230,4 kBaud) Function Process data, parameterization, diagnosis, data storage Digital input 1 Response time depends on the measuring speed Digital output Number 1 ... 2 1) 2) 3) Type Push-pull: PNP/NPN Function Complementary digital outputs (Q, Ǭ) Output Q2 adaptable: Current output / Voltage output / Digital output / Q1 not / deactivated Maximum output current IA ≤ 100 mA Analog output Number 1 Type Current output / voltage output Function Output Q2 adaptable: Current output / Voltage output / Digital output / Q1 not / deactivated Current 4 mA ... 20 mA, ≤ 450 Ω Voltage 0 V ... 10 V, ≤ 10,000 Ω Resolution 16 bit 1) Output Q short-circuit protected. 2) Voltage drop < 3 V. 3) Max. total output current < 200 mA. 2024-04-23 09:56:20 | Product data sheet Subject to change without notice LASER DISTANCE SENSORS | SICK 3

A B C D E F H I J K L M N O P Q R S T DT80-311111 | Dx80 MID RANGE DISTANCE SENSORS Ambient data Ambient temperature, operation –10 °C ... +50 °C, Uv ≤ 30 V Ambient temperature, storage –40 °C ... +75 °C Temperature drift Typ. 0.05 mm/K Typ. Ambient light immunity 30,000 lx Vibration resistance (IEC 60068-2-6:2007) Sinusoidal resonance measurement: 10 Hz ... 1,000 Hz (IEC 60068-2-64:2008) Noise test: 20 Hz ... 500 Hz, 10 g RMS, 2 h / axis Shock resistance (IEC 60068-2-27:2008) 30 g, 11 ms, 6 axes, ± 3 single shocks / axis, (IEC 60068-2-27:2008) 10 g, 6 ms, 6 axes, ± 500 shocks / axis, (IEC 60068-2-27:2008) 70 g, 6 ms, 1 axis, ± 100,000 shocks / axis Classifications ECLASS 5.0 27270801 ECLASS 5.1.4 27270801 ECLASS 6.0 27270801 ECLASS 6.2 27270801 ECLASS 7.0 27270801 ECLASS 8.0 27270801 ECLASS 8.1 27270801 ECLASS 9.0 27270801 ECLASS 10.0 27270801 ECLASS 11.0 27270801 ECLASS 12.0 27270916 ETIM 5.0 EC001825 ETIM 6.0 EC001825 ETIM 7.0 EC001825 ETIM 8.0 EC001825 UNSPSC 16.0901 41111613

4 LASER DISTANCE SENSORS | SICK Product data sheet | 2024-04-23 09:56:20

Subject to change without notice

DT80-311111 | Dx80 MID RANGE DISTANCE SENSORS Dimensional drawing (Dimensions in mm (inch)) LNK PWR 57.04 (2.25) Ø 4.5 (0.18) 45.97 (1.81) 135° 93° 45° 3 (0.12) Ø 4.5 (0.18) 33 (1.30) 65 (2.56) 42.75 (1.68) 31.17 (1.23) 19.84 (0.78) 16.5 (0.65) 300 (11.81) ① Optical axis, sender ② Optical axis, receiver ③ Reference surface (corresponds to distance 0 mm) ④ M4 fixing holes ⑤ Cable with plug M12, 5-pin 2024-04-23 09:56:20 | Product data sheet Subject to change without notice LASER DISTANCE SENSORS | SICK 5

A B C D E F H I J K L M N O P Q R S T DT80-311111 | Dx80 MID RANGE DISTANCE SENSORS Connection diagram L+ 1brn M3blu Q1/C 4blk QA/Q 2/¯Q1/– 2wht MF 5gra 1 ① Multifunctional input (MF) Repeatability 6% remission, 10,000 Lux Typ. repeatability in mm (inch) 1 Distance in m (ft) 2 (6.6) (13.1) (19.7) (26.2) (32.8) (39.4) (45.9) (52.5) 0.50 (0.02) 1.00 (0.04) 1.50 (0.06) 2.00 (0.08) 2.50 (0.10) 3.00 (0.12) 3.50 (0.14) 4.00 (0.16) a: 33 ms b: 50 ms c: 100 ms d: 200 ms d c b a ① Typical repeatability in mm (inches) ② Distance in meters (feet)

6 LASER DISTANCE SENSORS | SICK Product data sheet | 2024-04-23 09:56:20

Subject to change without notice

DT80-311111 | Dx80 MID RANGE DISTANCE SENSORS 6% remission, 30,000 Lux Typ. repeatability in mm (inch) 1 Distance in m (ft) 2 (6.6) (13.1) (19.7) (26.2) (32.8) (39.4) (45.9) (52.5) 0.50 (0.02) 1.00 (0.04) 1.50 (0.06) 2.00 (0.08) 2.50 (0.10) 3.00 (0.12) 3.50 (0.14) 4.00 (0.16) a: 33 ms b: 50 ms c: 100 ms d: 200 ms d c b a ① Typical repeatability in mm (inches) ② Distance in meters (feet) 90% remission, 10,000 Lux Typ. repeatability in mm (inch) 1 Distance in m (ft) 2 (16.4) (32.8) (49.2) (65.6) (82.0) (98.4) (114.8) (131.2) 0.50 (0.02) 1.00 (0.04) 1.50 (0.06) 2.00 (0.08) 2.50 (0.10) 3.00 (0.12) 3.50 (0.14) 4.00 (0.16) a: 33 ms b: 50 ms c: 100 ms d: 200 ms d c b a ① Typical repeatability in mm (inches) ② Distance in meters (feet) 2024-04-23 09:56:20 | Product data sheet Subject to change without notice LASER DISTANCE SENSORS | SICK 7

A B C D E F H I J K L M N O P Q R S T DT80-311111 | Dx80 MID RANGE DISTANCE SENSORS 90% remission, 30,000 Lux Typ. repeatability in mm (inch) 1 Distance in m (ft) 2 (16.4) (32.8) (49.2) (65.6) (82.0) (98.4) (114.8) (131.2) 0.50 (0.02) 1.00 (0.04) 1.50 (0.06) 2.00 (0.08) 2.50 (0.10) 3.00 (0.12) 3.50 (0.14) 4.00 (0.16) a: 33 ms b: 50 ms c: 100 ms d: 200 ms d c b a ① Typical repeatability in mm (inches) ② Distance in meters (feet) Recommended accessories Other models and accessories www.sick.com/Dx80 Brief description Type Part no. Mounting brackets and plates Mounting bracket, steel, zinc coated, steel, zinc coated, mounting hardware for the sen- sor included BEF-WN-DX50 2048370 Plug connectors and cables

  • Connection type head A: Female connector, M12, 5-pin, straight, A-coded
  • Connection type head B: Flying leads
  • Signal type: Sensor/actuator cable
  • Cable: 2 m, 5-wire, PVC
  • Description: Sensor/actuator cable, unshielded
  • Application: Zones with chemicals YF2A15- 020VB5XLEAX 2096239
  • Connection type head A: Female connector, M12, 5-pin, straight, A-coded
  • Connection type head B: Male connector, M12, 5-pin, straight, A-coded
  • Signal type: Sensor/actuator cable
  • Cable: 2 m, 5-wire, PUR, halogen-free
  • Description: Sensor/actuator cable, unshielded
  • Application: Zones with oils and lubricants, Drag chain operation, Robot YF2A15- 020UB5M2A15 2096009

8 LASER DISTANCE SENSORS | SICK Product data sheet | 2024-04-23 09:56:20

Subject to change without notice

DT80-311111 | Dx80 MID RANGE DISTANCE SENSORS Brief description Type Part no. Terminal and alignment brackets Alignment unit, steel, zinc coated, mounting hardware for the sensor included BEF-AH-DX50 2048397 2024-04-23 09:56:20 | Product data sheet Subject to change without notice LASER DISTANCE SENSORS | SICK 9

SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com