IOX018-130 DANFOSS | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

Features

  • User-programmable with PLUS+1 GUIDE (Graphical User Integrated Development Environment)
  • 18 pins: (2) DEUTSCH connectors (DT and DTP), (2) 6 mm studs
  • 12 bit analog-to-digital converter
  • ARM 32 bit Cortex-M3 running at 120 MHz Comprehensive technical literature is online at www.danfoss.com Data Sheet PLUS+1® Expansion Module IOX018-130 High Current © Danfoss | March 2019 AI297367135765en-000102 | 1
  • (2) Universal (DIN/AIN/FreqIN/Rheo) Digital: Pull up (5 VDC), pull down (0 VDC) or pull to center (2.5 VDC) Analog: 0 to 0.375 VDC, 0 to 5.25 VDC, or 0 to 36 VDC Frequency (timing): 1 Hz to 10 kHz Resistance: 0 to 10,000 ohm
  • (1) Digital/Analog (DIN/AIN) that is user- defined as either: Digital: Pull up (5 VDC), pull down (0 VDC) or pull to center (2.5 VDC) Analog: 0 to 5.25 VDC or 0 to 36 VDC
  • (1) Digital/Analog/CAN shield (DIN/AIN/CAN shield) that is user- defined as either: Digital: Pull up (5 VDC), pull down (0 VDC) or pull to center (2.5 VDC) Analog: 0 to 5.25 VDC or 0 to 36 VDC CAN shield 8 outputs
  • (4) Universal (PWMOUT/DOUT/PVGOUT) that are user-defined as either: Digital: 15 A, configurable as source or sink PWM: 15 A (33 to 4000 Hz or 20 kHz), configurable as open or closed loop with current control
  • (4) Universal (PWMOUT/DOUT/PVGOUT) that are user-defined as either: Digital: 25 A, configurable as source or sink PWM: 25 A (33 to 4000 Hz or 20 kHz), configurable as open or closed loop with current control Characteristics Supply voltage 9 to 36 VDC Operating temperature (ambient) – 40°C to 70°C [– 40°F to 158°F] Storage temperature – 40°C to 85°C [– 40°F to 185°F] Programming temperature – 40°C to 70°C [– 40°F to 158°F] IP rating (with mating connector attached) IP 67 EMI/RFI rating 100 V/M Weight 1.29 kg [2.85 lb] Vibration IEC 60068-2-64 Shock IEC 60068-2-27 test Ea Maximum current, sourcing 120 A Maximum current, sinking 120 A Data Sheet IOX018-130 High Current Expansion Module 2 | © Danfoss | March 2019 AI297367135765en-000102

Dimensions and pin assignments Dimensions in millimeters M6 locknut Install torque 7.344 N•m 2X 10 M6 Threaded stud Red LED Green LED 80.2 11.7 12.3 173 2X 151 4X Ø 6.75 2X 167 189 ohj1479876644922 C3C4 Device must be mounted on a flat metal surface that is less than 70° C (158° F) for full output capability. If the metal surface is greater than 70° C (158° F), built in thermal protection will limit the maximum output current allowed for all PWM’s. Use care when wiring mating connector. Pinouts are for device pins. DEUTSCH DT Series 12 pin nmp1479876497075 Pin Controller function Pin Controller function

1 Logic ground 7 DIN/AIN/FreqIN/Rheo

2 Logic power 8 DIN/AIN/FreqIN/Rheo

3 CAN_HI 9 15A PWM

4 CAN_LO 10 15A PWM

5 DIN/AIN1/CAN shield 11 15A PWM

6 DIN/AIN2 12 15A PWM

C3, C4 Pin Controller function Description C3-P1 Battery power 120A battery connection (externally fused) C4-P1 Battery ground 120A battery connection Data Sheet IOX018-130 High Current Expansion Module © Danfoss | March 2019 AI297367135765en-000102 | 3

Ordering information

Related products part numbers CG150-2 CAN/USB Gateway 11153051 PLUS+1 GUIDE Professional 11179523 Danfoss mating connectors bag assemblies and fuse part numbers 4 pin DEUTSCH mating connector bag assembly (10 to 14 AWG) 11188220 12 pin DEUTSCH mating connector bag assembly (14 to 20 AWG) 11188221 4 and 12 pin DEUTSCH mating connector bag assembly 11188232

125 Amp fuse 11188233

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 4 | © Danfoss | March 2019 AI297367135765en-000102