www.e-t-a.de 1646 Thermal Circuit Breaker 1115-...

Description

Current ratings and typical voltage drop Technical Data Single pole thermal reset circuit breaker l Space-saving, slim design l Ease of installation through snap-in frame l Reliable, trip-free mechanism l Approvals: UL1077, EN60934 l Attractively low price Power supply units, UPS equipment, battery chargers, oxygen treat- ment devices, office machines 1115 Type No. 1115 single pole thermal circuit breaker Mounting method F1 snap-in mounting Number of poles 1 1 pole, thermally protected Accessories, style 1 black push button Terminals P1 blade terminals A 6.3 x 0.8 mm Characteristic curve T1 thermal 3...16 A T2 thermal 1...2.5 A Current ratings 1...16A 1115 - F1 1 1 -P1 T1 - 10 A ordering example Approval authority Standard Rated voltage Current rating range Approval mark UL UL1077 (E67320) AC 250 V DC 32 V 1...16 A TÜV EN 60934/ IEC 60934 AC 250 V 1...16 A Rated voltage AC 250 V; DC 32 V Current rating range 1...16 A Typical life 500 operations at 1.5 times rated current, resistive load, AC 125 V 50 operations at 2 times rated current, inductive load, AC 250 V Rupture capacity UL1077 EN 60934

1.000 A (C, 1), AC 250 V

200 A (C, 1), DC 32 V

500 A (I

NC1), AC 250 V Ambient temperature -20°C … + 60°C Vibration 57 Hz acceleration 30m/s2 (3g) in X, Y , Z directions (twice/min.) Shock 300m/s2 (30g) in X, Y , Z directions Mass approx. 8g Cut-out dimensions 13,8 + 0,2 – 0 Ø 15,8 + 0,2 Current rating range (A) Voltage drop (mV) Current rating range (A) Voltage drop (mV) 1 < 1000 8 < 250 1,5 < 500 9 < 250 2 < 500 10 < 250 2,5 < 500 11 < 250 3 < 250 12 < 250 3,5 < 250 13 < 250 4 < 250 14 < 250 5 < 250 15 < 250 6 < 250 16 < 250 7 < 250

Thermal Circuit Breaker 1115-... www.e-t-a.de 1646 Dimensions Schematic diagram 19,0 13,5 9,5 39,5 7,2 14,8 6,3 0,8 19,0 9,0 A Time/current characteristics All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness, the right to make changes in these specifications with- out notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. ±IT13 to DIN ISO 286 applies to nominal dimensions without tolerances No trip 100% must trip 150% No trip 100% must trip 135% Trip time in secondsTrip time in seconds … times rated current … times rated current 0,8 1 1,5 2 4 6 8 10 20 40 10000 1000 100 0,1 0,8 1 1,35 2 4 6 8 10 20 40 10000 1000 100 0,1 T2: 1...2.5 A T1: 3...16 A The time/current characteristic depends on the ambient temperature. In order to eliminate nuisance tripping, please multiply the current rating by a derating factor (see chapter Technical Information) ambient temperature [°C] -20 -10 0 +10 +25 +35 +40 +50 +60 Temperature factor