MC012-110 DANFOSS | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 4
Technical content
Features
- User-programmable with PLUS+1 GUIDE (Graphical User Integrated Development Environment)
- ARM 32 bit Cortex-M3 running at 120 MHz ‒ 12 bit analog-to-digital converter ‒ 16 bit timers/counters
- FRAM non-volatile memory
- 12 pin DEUTSCH DTM connector
- 9 to 36 Vdc power supply, monitored internally
- 1 CAN 2.0B port, the fixed range analog input can be configured as the shield pin
- Power supply for external sensors rated at 5 Vdc to 100 mA and regulated internally
- 2 LEDs under user control
- 3 mounting alternatives: stack, end , or side
- The MC012-112 controller contains the application key required to run Danfoss developed machine control application software
- CE compliant Comprehensive technical literature online at powersolutions.danfoss.com Data Sheet PLUS+1® Controllers MC012-110 and MC012-112 © Danfoss | Sept 2016 AI00000155en-US0403 | 1
4 Inputs
- (3) universal (DIN/AIN/FreqIN/Rheo) that are user-defined as either: ‒ Analog: with configurable ranges 0 to
5.25 Vdc (with over range protection)
‒ Digital: pull up (5 Vdc), pull down (0 Vdc) or pull to center (2.5 Vdc) ‒ Frequency (timing): 1 Hz to 10 kHz ‒ Resistance: 0 to 10,000 ohm
- (1) fixed range analog (AIN/CAN shield) 0 to 5.25 Vdc or CAN shield pin
2 Outputs
- (2) universal (PWMOUT/DOUT/PVGOUT) that are user-defined as either: ‒ Digital: (3 A), configurable as source or sink ‒ PWM: (30 to 4000 Hz), configurable as open or closed loop with current control ‒ Analog voltage: open loop PWM at 4000 Hz
- Any PWMOUT/DOUT/PVGOUT can be used to provide reference power to one PVG valve Specifications Product parameters Supply voltage 9 to 36 Vdc Operating temperature (ambient) -40°C to 70°C [-40°F to 158°F] Storage temperature -40°C to 85°C [-40°F to 185°F] Programming temperature 0°C to 70°C [32°F to 158°F] IP rating (with mating connector attached) IP 67 EMI/RFI rating 100 V/M Weight 0.40 kg [0.88 lb] Vibration IEC 60068-2-64 Shock IEC 60068-2-27 test Ea Maximum current, sourcing 8 A Maximum current, sinking 8 A Data Sheet MC012-110 and 112 2 | © Danfoss | Sept 2016 AI00000155en-US0403
Dimensions and pin assignments 114.4 [4.50] 158.2 [6.23] 2 X 25.3 [1.0] 107.0 [4.21] 62.0 [2.44] 35.3 [1.39] 51.6 [2.03] 47.1 [1.85] 144.5 [5.69] 2199A CCaution This device is not field serviceable. Opening the device housing will void the warranty.
12 Pin Connector
C1-P6 5 Vdc sensor power + C1-P7 Sensor power ground - C1-P8 DIN/AIN/FreqIN/Rheo C1-P9 DIN/AIN/FreqIN/Rheo C1-P10 DIN/AIN/FreqIN/Rheo C1-P11 PWMOUT/DOUT/PVGOUT C1-P12 PWMOUT/DOUT/PVGOUT Use care when wiring mating connector. Pinouts listed are for device pins. Data Sheet MC012-110 and 112 © Danfoss | Sept 2016 AI00000155en-US0403 | 3
Ordering information
MC012-110 part number 11130915 MC012-112 part number 11130916 Related products part numbers CG150 CAN/USB Gateway 10104136 DEUTSCH mating connector bag assembly 10102025 (16 to 20 AWG) 10100944 (20 to 24 AWG) PLUS+1 GUIDE single user license 10101000 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 4 | © Danfoss | Sept 2016 AI00000155en-US0403