Features

  • Single Pole / Single Throw (SPST)
  • Preset temperature set points, non-adjustable calibration
  • High resistance to shock and vibration
  • Hermetically sealed, vacuum baked and back-filled with nitrogen
  • Various mounting configurations available
  • Qualified to MIL-PRF-24236/1
  • Qualified to NASA S-311-P641/05 The Klixon® M1/11041 series of thermostats are engineered for exceptional vibration and shock resistance to provide reliable switching in the most demanding applications. Prior to the final weld, finished assemblies are vacuum baked and back–filled with dry nitrogen. The inert, dry atmosphere eliminates moisture and other volatilizes to prevent condensation at low temperatures or possible contact contamination at high temperatures. This back–fill also improves the dielectric characteristics of the device and prevents oxidation of the contacts. The M1 thermostat is the ideal choice where quality and reliability are paramount. Contact Ratings (Resistive) Cycles 100,000 50,000 25,000 10,000 5,000 30VDC / 30VAC 5.0 amps 5.5 amps 6.0 amps 6.5 amps 7.0 amps 125VAC 2.0 amps 3.0 amps 4.0 amps 5.0 amps 6.0 amps 250VAC 1.0 amps 1.5 amps 2.0 amps 2.5 amps 3.0 amps Contact ratings shown are based on the standard differential shown under Standard Temperature Settings Operating Temperature -65°F to 550°F (-53.9°C to 287.8°C) Dielectric Strength 1250 VAC, rms, 60 cycles for 1 minute, terminal to case per MIL-STD-202, Method 301 Contact Resistance 0.050 ohms maximum per MIL-STD-202, Method 307 Insulation Resistance 100 megohms min. at 500 VDC Vibration 5-2000 Hz, 20G, per MIL-STD-202, Method 204, Condition D (monitored) 5-1000 Hz, 100G, per MIL-STD-202, Method 204, Condition D (unmonitored) 1000-2000 Hz, 50G, per MIL-STD-202, Method 204, Condition D (unmonitored) Shock 100G, 6 milliseconds, per MIL-STD-202, Method 213 SPECIFICATIONS

www.sensata.com Page 2 Copyright © 2018 Sensata Technologies, Inc. Standard Temperature Settings Hermeticity 1 x 10-8 atm cc/sec. maximum, per MIL-STD-202, Method 112, Condition C Salt Spray Per MIL-STD-202, Method 101, Condition B, 5% solution Average Weight 4.8 grams (without bracket) to 5.9 grams (with bracket) Ambient Temperature Range -80°F to +550°F (-62.2°C to 287.8°C) Maximum ambient exposure while in the closed position is 200°F above contact closing temperature. Sensata can manufacture thermostats to any custom set point temperature within the specified operating temperature range. The table gives standard limits for our thermostats. Contact factory for assistance with custom set point temperatures. Operating Temp. Range (°F) Available Differential Range (°F) Temperature Tolerance (°F) Minimum Standard Maximum Open Closed -65 to -1 25 30 80 ±10 ±8 0 to +200 9 20 80 ±5 ±5 +201 to +300 20 30 80 ±8 ±6 +301 to +450 30 40 80 ±12 ±12 +451 to +550 60 70 80 ±25 ±25 Notes: 1. Thermostat life is reduced when at minimum or maximum differential 2. Differential is the difference between the nominal Open & Close temperature set points COMMON CONFIGURATIONS No Bracket | SPST (Single Pole, Single Throw) All dimensions are in millimeters (Inches). NOTE: Stud mount, surface and top mounting brackets are available. Dimensions listed are for reference only. Please contact Sensata for more detailed envelope drawings.

www.sensata.com Page 3 Copyright © 2018 Sensata Technologies, Inc. ORDERING OPTIONS Example : M1 110 090 2 8 2 Product Series Top Temperature Setting (°F) Operation Bottom Temperature Setting (°F) Mounting and Terminals (See Configurations) Plating Use 3 digits (insert minus sign plus two digits for temps below 0°F) 1 = Open on rise, silver contacts 2 = Close on rise, silver contacts 3 = Open on rise, gold contacts 4 = Close on rise, gold contacts Use 3 digits (insert minus sign plus two digits for temps below 0°F) Odd #’s = Flattened and pierced terminals Even #’s = 90° right angle terminals 1 & 2 = No mounting 3 & 4 = Top mounting bracket 7 & 8 = Surface mounting bracket 9 & 0 = Stud mounting 2 = Copper / nickel 4 = Tin M1 110 2090 8 2 The example above describes a M1 series thermostat which closes on temperature rise at 110°F, opens at 90°F, has silver contacts, a surface mounting bracket, 90˚ bent terminals, and is plated with copper/nickel Configurations built to the standard tolerances and differentials are available as the M1 series and are described above. Customers should order an 11041 series thermostat if the application requires custom set point tolerances, differentials, or physical configurations not available as an M1 For applications that require thermostat certified to the M24236, customers must order to the M24236/1 part number. For applications that require the thermostat to be certified to NASA S-311-P641/05, customers should contact the factory to ensure the correct part number

Rev:10/05/18 www.sensata.com Copyright © 2018 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Americas +1 (508)-236-3287 klixon@sensata.com AUTHORIZED DISTRIBUTORS Flame Enterprises Bob Correa, Director of Product Management +1 (240) 236-9802 bcorrea@flamecorp.com info@flamecorp.com | Web Tel: 1-800-854-2255 or 1-818- 700-2905 Fax: 1-818-407-5080 Peerless Electronics Steve Gunther, National Sales Manager +1 (516) 594-3509 sgunther@peerlesselectronics. com nysales@peerlesselectronics. com | Web Tel: 1-800-285-2121 Fax: 1-800-222-8096 Europe, Middle East & Africa Flame Enterprises Bob Correa, Director of Product Management +1 (240) 236-9802 bcorrea@flamecorp.com info@flamecorp.com | Web Tel: 1-800-854-2255 or 1-818- 700-2905 Fax: 1-818-407-5080 CONTACT US WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE

  • The product’s side panels may be hot, allow the product to cool before touching
  • Follow proper mounting instructions including torque values
  • Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
  • Disconnect all power before installing or working with this equipment
  • Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury