10HVA ADVANCEDENERGY | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 6
Technical content
©2023 Advanced Energy Industries, Inc. The UltraVolt® 10HVA – 20HVA series of DC-to-DC high voltage power supplies operates a precision filter / divider and linear HV switch to produce a high voltage amplifier (HVA). These modules provide a high-resolution, high voltage DC to full scale waveform capability greater than 500 Hz output. 10 / 15 / 20 kV HVA modules are optimized for bias applications while providing excellent line regulation, load regulation, dynamic response, and stability. The HVA series can both source and sink current operating linearly through 0 V with low ripple and noise over the entire output range. PRODUCT HIGHLIGHTS ULTRAVOLT 10HVA – 20HVA SERIES PRECISION HIGH VOLTAGE AMPLIFIER Bipolar models available at 0 to 10 kV, 15 kV, 20 kV Unipolar models available at 0 to 15 kV and 20 kV Operates in DC, reversible, and amplifier modes Fast slew rate and high bandwidth at an excellent value Can both source and sink current PPM level line & load regulation 50 ppm temperature coefficient (25 ppm optional) Reduced ripple option available Differential precision 0 to 10 VDC control input Precision voltage and current monitors TYPICAL APPLICATIONS Drivers
- Electrohydrodynamics
- Electrostatic chuck
- Pockels cells
- Laser and electro-optic modulation
- Electrophoresis Amplifiers
- Ion beam and electron beam devices such as mass spectrometry, and electron microscopes as well as electrostatic deflection/focusing, flocking, coating, electrospinning, precipitation and electrocoalescence
2 advancedenergy.com ULTRAVOLT 10HVA – 20HVA SERIES ELECTRICAL SPECIFICATIONS Parameter Conditions Models Units Input All Types Voltage Range Full Power 24 VDC ± 10% VDC Current Standby / Disable <70 unipolar, <105 bipolar mA Current Full Load, Max Eout 750 Bipolar-1 W=850/1.5 W=900 Unipolar-1 W=650/1.5 W=700 Bipolar-1 W=950/2 W=1025 Unipolar-1 W=750/2 W=825 mA Current No Load, Max Eout 675 Bipolar-1 W=775/1.5 W=825 Unipolar-1 W=575/1.5 W=625 Bipolar-1 W=875/2 W=950 Unipolar-1 W=675/2 W=750 mA Output ±10 kV 15 kV/±15 kV 20 kV/±20 kV Power Nominal Input, Max Eout 1 1 1.5 1 2 W Current Iout Entire Voltage Range 100 66 100 50 100 uA Voltage Monitor Normal Operating Conditions 0 to 10 ± 0.5% VDC Current Monitor Normal Operating Conditions 0 to 10 ± 1% VDC Line Regulation Vin Min to Vin Max, Max Eout <0.01 % Load Regulation No Load to Full Load, Max Eout <0.01 % Programming and Controls All Types Input Impedance Normal Operating Conditions 10 MΩ Adjust Voltage Differential 0 to +10 VDC HV ON/OFF (Enable/Disable) 0 to +0.8 V Disable, +2.5 to +10 Enable (Default = Disable) VDC Reference Voltage +10.00 ± 0.05% VDC Max Source Current 5 mA Environmental All Types Operating Full Load, Max Eout, Case Temp. +10 to +45 °C Temperature Coefficient Over the Specified Temperature ±50 ppm or ±25 ppm (Optional) ppm/°C Storage Non-Operating, Case Temp. -40 to +100 °C Humidity All Conditions, Standard Package 0 to 95% non-condensing - Altitude Standard Package, All Conditions Sea Level through 10,000 ft Shock Mil-Std-810, Method 516, Proc. 4 20 Gs Vibration Mil-Std-810, Method 514, Fig. 514-3 10 Gs 1 Units listed without polarity can be ordered as positive (+) or negative (-). Units listed as (±) are bipolar.
advancedenergy.com 3 ULTRAVOLT 10HVA – 20HVA SERIES MECHANICAL SPECIFICATIONS Construction Standard Case Aluminum (Anodized per MIL-A-8625 Type ll) Finish Blue Anodized Size 95.06 in3 (1557.8 cm3) Tolerance Overall: ±0.030 in (1.27 mm) Mounting Hole Location: ±0.025 in (0.64 mm) Encapsulation Silicone-based RTV (contact factory for other options) Weight 2.54 kg, 5.6Ib
4 advancedenergy.com ULTRAVOLT 10HVA – 20HVA SERIES INTERFACE Connections D-Sub 15-Pin, Female HV Connector LGH1Li HV Return #6-32 x 0.437 Long 1 Requires mating cable CA-25KV-1000 to operate. (Sold Separately) HVA Input Connector Pinout Functinos Pin Description Function 1 Reference Voltage +10.00 V precision reference 2 Voltage Programming - 0 to +10 V or 0 to -10 V to program full output voltage, depending on polarity. Programming input is differential between pins 2 and 3.3 Voltage Programming +
4 Voltage Monitor 0 to ±10 V represents 0 to ± full output voltage
5 N/C No connection
6 Signal Ground Reference all control signals here
7 Input Power
+24 V Input Power
8 Input Power
9 Power Ground
10 Power Ground
11 Enable TTL high to enable, low to disable, default is OFF
12 Current Monitor 0 to ±10 V represents 0 to ± full output current
13 Current Limit Adjust 0 to +10 V sets current limit from 0 to full rated output current
14 N/C No connection
15 Signal Ground Reference all control signals here
advancedenergy.com 5 ULTRAVOLT 10HVA – 20HVA SERIES
ORDERING INFORMATION
Type 0 to 10,000 VDC Output 10HVA 0 to 15,000 VDC Output 15HVA 0 to 20,000 VDC Output 20HVA Input 24 VDC Nominal 24 Polarity Positive Output -P Negative Output -N Bipolar Output -BP Power 1 Watt Output 1 1.5 Watt Output @ 15kV Only 1.5
2 Watt Output @ 20kV Only 2
Option Ripple Stripper® Output Filter -F 25 ppm temperature coefficient -25PPM Connections LGH1Li Standard Shielded Flying Lead for HV Output WS 20HVA24-BP2-F Option Polarity Power Voltage Model Input
For international contact information, visit advanced-energy .com. uv-ca@aei.com +1.970.221.0108 ABOUT ADVANCED ENERGY Since 1981, UltraVolt® — now part of the Advanced Energy (AE) family — has perfected how power performs for its customers. For both end users and OEMs, AE’s comprehensive portfolio of standard and custom high voltage components precisely match system specifications to deliver unparalleled energy, quality, and performance. Through close customer collaboration, design expertise, application insight, and world-class support, AE creates successful partnerships and enables customers to push the boundaries of innovation and stay ahead of evolving market needs. PRECISION | POWER | PERFORMANCE Read and understand all documentation before you install, operate, or maintain Advanced Energy high voltage power supplies. Follow all safety instructions and precautions to protect against property damage and serious or possibly fatal bodily injury. Never defeat safety interlocks or grounds. CAUTION: High Voltage Specifications are subject to change without notice. Not responsible for errors or omissions. ©2023 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, AE®, and UltraVolt® are U.S. trademarks of Advanced Energy Industries, Inc. DS TITLE ENG-HV-HVA10-20series-235-02 4.07.23