Product: 10GXE02 10GX Category 6A Enhanced Cable, 4 Pair, S/FTP, LSZH Indoor CPR Eca Product Description Category 6A Enhanced Premise Horizontal Cable (625MHz), 4-Pair, 23 AWG Solid Bare Copper conductors, S/FTP, Foam Polyethylene insulation, each pair with Beldfoil® shield, tinned copper braid shield (30%), LSZH jacket, CPR Euroclass Eca Technical Specifications Product Overview Suitable Applications: Horizontal and building backbone cable; Support current and future Category 6A and 6 applications, such as: 10GBase-T (10 Gigabit Ethernet), 1000Base-T (Gigabit Ethernet),

100 Base-T, 10 Base-T, FDDI, ATM

Element Size Stranding Material Number of Pairs Number of Element Individual Shielded Pair 23 AWG Solid BC - Bare Copper 4 8 Insulation Element Material Nom. Insulation Diameter Color Code Individual Shielded Pair PE - Polyethylene (Foam) 1.32 mm (0.0520 in) White & Blue, White & Orange, White & Green, White & Brown Cable Core

Description

Element Shield Type Material Coverage Individual Shielded Pair Tape Bi-Laminate (Alum+Poly) 100% Table Notes: Aluminum facing outside Outer Shield Shield Type Material Coverage Braid Tinned Copper (TC) 30% Outer Jacket Material Nom. Diameter Ripcord LSZH - Low Smoke Zero Halogen (Flame Retardant) 7.0 mm (0.28 in) Yes Overall Cable Diameter (Nominal): 7.0 mm (0.28 in)

Electrical Characteristics

Max. Conductor DCR Max. Mutual Capacitance Max. Capacitance Unbalance Nom. Characteristic Impedance

95 Ohm/km 56 pF/m (17 pF/ft) 160 pF/100m 100 Ohm

Max. Delay Skew Nom. Velocity of Prop. 45 ns/100m 77%

[MHz] Max. Insertion Loss (Attenuation) Min. NEXT [dB] Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Min. PSANEXT [dB] Min. PSAACRF [dB] Min. TCL [dB] Min. ELTCTL [dB] Table Notes: Limits below 4 MHz and at 625 MHz are for information only. Reference standard: IEC 61156-5 Transfer Impedance Frequency Max. Transfer Impedance 1 Mhz Max. 50 mOhm/m 10 Mhz Max. 100 mOhm/m 30 Mhz Max. 200 mOhm/m 100 Mhz Max. 1000 mOhm/m Transfer Impedance Class: Grade 2 Screening Class: Type Ib Table Notes: Coupling Attenuation Voltage Voltage Rating

72 V DC

Mechanical Characteristics Temperature Operating Installation -30°C to +60°C 0°C To +50°C Bend Radius Stationary Min. Installation Min. 29 mm (1.1 in) 58 mm Max. Pull Tension: 85 N (19 lbf) Bulk Cable Weight: 52 kg/km Standards and Compliance Environmental Suitability: Indoor - Euroclass Eca Flammability / Reaction to Fire: IEC 60332-1-2 CPR Compliance: CPR Euroclass: Eca; CPR UKCA Class: Eca IEEE Compliance: PoE: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 Data Category: Category 6A TIA/EIA Compliance: ANSI/TIA 568.2-D ISO/IEC Compliance: ISO/IEC 11801-1, IEC 61034-2 - Smoke Density Min Transmittance = 60% CENELEC Compliance: EN 50173-1, Segregation class according EN50174-2 = d European Halogen Free Standards: IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 2.5 µS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3 European Directive Compliance: EU CE Mark UK Regulation Compliance: UKCA Mark Product Notes Notes: Electrical values are expected performance based on cable testing and representative performance within a typical Belden system.

Update and Revision: Revision Number: 0.290 Revision Date: 11-09-2022 Part Numbers Variants Item # Color Putup Type Length EAN 10GXE02.06500 Blue Reel 500 m 8719605000385 10GXE02.08100 Gray Reel 100 m 8719605000408 10GXE02.K8100 Gray Reel 100 m 8719605147868 10GXE02.08500 Gray Reel 500 m 8719605000415 10GXE02.03500 Orange Reel 500 m 8719605130068 10GXE02.07500 Purple Reel 500 m 8719605000392 10GXE02.02500 Red Reel 500 m 8719605195012 10GXE02.04500 Yellow Reel 500 m 8719605195029 © 2022 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.