10GX53F BELDEN | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Part Number: 10GX53F CAT6A (625MHz), 4 Unbonded Pairs, F/UTP-Foil Shielded, CMP Product Description CAT6A (625MHz), 4 Unbonded Pairs, F/UTP-Foil Shielded, Plenum-CMP, Premise Horizontal Cable, 23 AWG Solid Bare Copper Conductors, FEP Insulation, Patented EquiSpline™, Overall Foil Screen with Drain Wire, Ripcord, Flamarrest® Jacket Technical Specifications Product Overview Suitable Applications: Premise Horizontal Cable, 10 Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio, AES51, RS-422, Noisy Environments, PoE, PoE+ Physical Characteristics (Overall) Conductor AWG Stranding Material No. of Pairs

23 Solid BC - Bare Copper 4

Conductor Count: 8 Total Number of Pairs: 4 Insulation Material FEP - Fluorinated Ethylene Propylene Bonded-Pair: N/A Color Chart Number Color

1 White & Blue

2 White & Orange

3 White & Green

4 White & Brown

Type Material Material Trade Name Coverage [%] Drainwire Material Drainwire AWG Tape Aluminum/Polyester Beldfoil® 100 % TC - Tinned Copper 26 Outer Jacket Material Material Material Trade Name Nominal Diameter Ripcord LS PVC - Low Smoke Polyvinyl Chloride Flamarrest® 0.275 in Yes

Electrical Characteristics

Max. Conductor DCR Max. DCR Unbalance Max DCR Unbalanced Between Pairs [%]

82 Ohm/km 4 % 5 %

Max. Capacitance Unbalance Nom.Mutual Capacitance 90 pF/100m 17 pF/ft

Frequency [MHz] Max. Delay Max. Delay Skew Nominal Velocity of Propagation (VP) [%] 100 MHz 537.6 ns/100m 45 ns/100m 68 % High Freq Frequency [MHz] Max. Insertion Loss (Attenuation) Min. PSNEXT [dB] Min. PSACR [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Max./Min. Input Impedance (unFitted) Max./Min. Fitted Impedance Min. PSANEXT Min. PSAACRF Min. TCL [dB] Min. ELTCTL [dB] Voltage UL Voltage Rating

300 V RMS

Installation Temp Range: +5°C To +50°C UL Temp Rating: 105°C Storage Temp Range: -20°C To +75°C Operating Temp Range: -20°C To +75°C Mechanical Characteristics Bulk Cable Weight: 38 lbs/1000ft Max Recommended Pulling Tension: 25 lbs Min Bend Radius During Installation: 2.75 in Min Bend Radius/Minor Axis: 2.25 in Standards NEC/(UL) Specification: CMP CEC/C(UL) Specification: CMP ISO/IEC Compliance: 11801 ed 2.2 (2011) Class EA CPR Euroclass: Eca Data Category: Category 6A ANSI Compliance: S-116-732-2013 Category 6A, ANSI/NEMA WC-66 Category 6A Telecommunications Standards: ANSI/TIA-568-C.2 Category 6A IEEE Specification: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 Other Specification: Verified Channel/Category 6A Other Standards: C(UL)US CMP 105C OR (UL) CMP-LP (0.7A) OR CL3P-LP (0.7A) Applicable Environmental and Other Programs

Environmental Space: Plenum EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/11/EC (BFR): Yes EU Directive 2003/96/EC (BFR): Yes EU Directive 2011/65/EU (ROHS II): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU: Yes EU Directive Compliance: Yes EU CE Mark: Yes EU REACH SVHC Compliance (yyyy-mm-dd): 2017-07-10 EU RoHS Compliance Date (yyyy-mm-dd): 2014-03-27 CA Prop 65 (CJ for Wire & Cable): Yes Suitability Suitability - Aerial: No Suitability - Burial: No Suitability - Hazardous Locations: No Suitability - Indoor: Yes Suitability - Non-Halogenated: No Suitability - Oil Resistance: No Suitability - Outdoor: No Suitability - Sunlight Resistance: No Flammability, LS0H, Toxicity Testing UL Flammability: NFPA 262 Plenum (UL 910) CSA Flammability: FT6 ISO/IEC Flammability: IEC 60332-1-2 UL voltage rating: 300 V RMS Plenum/Non-Plenum Plenum (Y/N): Yes Part Number Non-Plenum Number: 10GX52F Variants Item # Color UPC 10GX53F 0101000 Black 612825377795 10GX53F D151000 Blue 612825377757 10GX53F 0081000 Gray 612825377771 10GX53F 0091000 White 612825377788 10GX53F 0041000 Yellow 612825377764 Patent: https://www.belden.com/resources/patents Product Notes Notes: Values above 625 MHz are for Engineering Information Only. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. History Update and Revision: Revision Number: 0.202 Revision Date: 08-22-2019 © 2019 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.