Power Inlet Filters & Power Entry Modules H Series Power Inlet Line Filter for Medical Equipment 169 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 For email, phone or live chat, please go to te.com/help corcom.com UL Recognized CSA Certified VDE Approved*

  • Minimal leakage current suitable for medical equipment
  • Two element circuit provides basic EMI attenuation above 1 MHz
  • Available with an internal ground circuit inductor (C suffix versions) to isolate equipment chassis from power line ground at radio frequencies
  • Flanged mounting the same as the EC, ED and EF Series
  • Capacitive output (see EAH, EBH and EJH Series for capacitive input) O rdering Inform ation

3 E H 1 C

1 – .250 [6.3] spade terminals 3 – Wire leads Power Inlet Style 4 – .250 [6.3] spade terminals (back) 5 – Wire leads (bottom) 8 – Wire leads (back) 9 – .250 [6.3] spade terminals (bottom) H Series Leakage current designation E – Low Leakage (<0.5 mA) Current Rating 3, 6, 10 or 15A EH9 Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: 2 A @250 VAC 50 Hz: 5 A Hipot rating (one minute): Line to Ground: 2250 VDC Line to Line: 1450 VDC Rated Voltage (max.): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 3 to 15A* Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculate d as follows: Io= Ir(85-Ta)/45 Specifications A vailable Part Num bers 3EH1 6EH8 3EH3 6EH9 6EH1 10EH1 6EH3 10EH3 6EH4 10EH4 6EH5 15EH4 Ground Circuit Inductor Versions 10EH4C *15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC EH1 EH8 EH5 *IEC 60320-1 C14 inlet mates with C13 connector EH4 E lectrical Schem atic LINE LOAD Note 1: 10EH4C version only

Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 For email, phone or live chat, please go to te.com/help corcom.com H Series Power Inlet Line Filter for Medical Equipment (continued) C ase Styles H1 (Chassis Mount) E B A D C H4 & H4C AD B C E C A F F B Brown Green/Yellow BlueD E C A F F B Brown Green/Yellow Blue D E Recom m ended Panel Cutouts .140 3.56 .062 1.58 .820 20.8 Typ. 1.200 30.48 1.575 40.01 .140 3.56 .234 5.94 .900 22.9 1.200 30.48 1.575 40.01 Front Mount Back Mount Typ. Tolerances ± .005 [0.13] unless otherwise noted H3 (Chassis Mount) E D A C B D E A C B .65 16.5 Max.

Power Inlet Line Filter for Medical Equipment (continued) Power Inlet Filters & Power Entry Modules 171 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 For email, phone or live chat, please go to te.com/help corcom.com Part No. ABCDEF 10EH4, 10EH4C C ase Dim ensions GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord A ccessories FA601: Insulating Shroud Dia..413 10.5 Dia..271 6.9 1.39 35.4 .118 3.0 1.17 29.7 .767 19.5 Perform ance Data Typical Insertion Loss 3EH 6EH Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Measured in closed 50 Ohm system 10EH db 100 0 0.01 0.1 1 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz db 100 0.1 1 10 30 Frequency in MHz db 100 Minimum Insertion Loss Common Mode / Asymmetrical (Line to Ground) Measured in closed 50 Ohm system 15EH db 100 0 0.01 0.1 1 10 30 Frequency in MHz