DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Power Entry Module with Switch 130 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 For email, phone or live chat, please go to te.com/help corcom.com UL Recognized CSA Certified VDE Approved*
- Two function power entry module combining a DPST switch and an IEC 60320-1 inlet
- Snap–in or flange mounting
- Available with or without a shielded general purpose or medical grade filter
- Two element circuit provides enhanced EMI attenuation
- Reduce OEM wiring time with optional pre–connected line and switch terminals O rdering Inform ation
10 C F S 1
1 – Spade terminals (size varies) Mounting Styles E – Flange Mount S – Snap–in Filter Type or Terminal Option F – General purpose H – Medical B – No filter, includes Pre–connected terminals Omit if none C Series Current Rating 1, 3, 6, 10 or 15A (Filtered versions up to 10A) Specifications Maximum leakage current each Line to Ground: F Models H & Unfiltered @ 120 VAC 60 Hz: .25 mA 2 A @250 VAC 50 Hz: .40 mA 5 A Hipot rating (one minute): Line to Ground: 2250 VDC Line to Line: 1450 VDC Rated Voltage: 250 VAC Operating Frequency: 50/60 Hz Rated Current: 1 to 15A* Switch: DPST 10,000 operations at 51A max. inrush .250 Terminal Push–on Force:18 lb. / 80N (max.) .188 Terminal Push–on Force: 15 lb. / 67N (max.) A vailable Part Num bers Filtered Versions 1CHE1 1CFE1 3CHE1 3CFE1 6CHE1 6CFE1 10CHE1 10CFE1 1CHS1 1CFS1 3CHS1 3CFS1 6CHS1 6CFS1 10CHS1 10CFS1 Non–filtered Versions Standard Terminals Pre-connected Terminals 10CS1 10CBS1 10CE1 10CBE1 15CS1 15CBS1 15CE1 15CBE1 *15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC 3CFS1 15CS1
Power Entry Module with Switch (continued) Power Inlet Filters & Power Entry Modules 131 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 For email, phone or live chat, please go to te.com/help corcom.com E lectrical Schem atics LINE LOAD F Models LINE LOAD H Models Note 1: Jumpers provided on CBS and CBE versions only. Note 2: Location of optional filter N Power On/Off L G L G N Note 1 Note 1 Note 2 Note 2 B Models C ase Styles CS, CBS A C B .210 5.34 Max. .210 5.34 Max. B A F C CE, CBE .210 5.34 Max. B A F C CFE, CHE .210 5.34 Max. BA C CFS, CHS
Power Entry Module with Switch (continued) 132 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 For email, phone or live chat, please go to te.com/help corcom.com C ase Styles (continued) CBS, CBE Pre-Connected Terminals CBS, CBE Side View CBE Rear View CBS Rear View Recom m ended Panel Cutout E F D R max.06 1.52 Part No. ABCDEF C ase Dim ensions GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord A ccessories
Power Entry Module with Switch (continued) Power Inlet Filters & Power Entry Modules 133 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 For email, phone or live chat, please go to te.com/help corcom.com Perform ance Data Typical Insertion Loss Minimum Insertion Loss Common Mode / Asymmetrical (Line to Ground) 1CF 0.1 1 10 30 Frequency in MHz db 100 3CF Measured in closed 50 Ohm system Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Measured in closed 50 Ohm system 6CF 10CF Differential Mode / Symmetrical (Line to Line) 1CH 3CH 6CH 10CH 0.1 1 10 30 Frequency in MHz db 100 00.1 1 10 30 Frequency in MHz db 100 00.1 1 10 30 Frequency in MHz db 100 db 100 0 0.01 0.1 1 10 30 Frequency in MHz db 100 0 0.01 0.1 1 10 30 Frequency in MHz db 100 0 0.01 0.1 1 10 30 Frequency in MHz db 100 0 0.01 0.1 1 10 30 Frequency in MHz