Convection, Air-Cooled Thermopile Sensors for Measuring Laser Power to 150 W These air-cooled, surface absorbing sensors are intended for measurement of low to medium power pulsed and CW lasers from the 10 mW to 150 W power range. Convection cooling makes them simple to operate as well as mechanically compact. Product numbers ending in “X” are specifically optimized for use with excimer lasers operating in the ultraviolet (150 nm to 400 nm). The DB-25 sensor models are compatible with LabMax-Pro, LabMax-TOP/TO, FieldMaxII-TOP/TO/P, and FieldMate meters.

FEATURES

  • Maximum powers from 2 W to 150 W
  • Minimum power down to 10 mW
  • Broadband and Excimer coatings
  • Convective air-cooled
  • 0.15 µm to 11 µm spectral range
  • 19 mm and 50 mm diameter active areas
  • DB25 (meter required)
  • RoHS Compliant

APPLICATIONS

  • Medical
  • Scientific
  • Industrial
  • General Laser Power Measurement from mW to 150 W

Air-Cooled Thermopile Sensors to 150 W Datasheet SPECIFICATIONS PM2 PM10 PM30 Wavelength Range (µm) 0.25 to 11 Power Range 10 mW to 2 W 10 mW to 10 W 100 mW to 30 W Long-Pulse Joules Range (J) 0.5 to 2 0.5 to 10 0.5 to 50 Maximum Intermittent Power (<5 min.) (W) 5 30 50 Resolution (mW) 1 1 10 Maximum Power Density (kW/cm 2) 6 Maximum Energy Density (mJ/cm 2) 600, 1064 nm, 10 ns Response Time (sec.) 2 Detector Coating Broadband Active Area Diameter (mm) 19 Calibration Uncertainty (%) (k=2) ±1 Calibration Wavelength (nm) 514 Cooling Method Air-cooled Cable Type PM DB-25 Cable Length (m) 2 Part Number 10983291 10979011 10983141 1 C24 Quick Ship program: eligible for next business day shipment. Adjustable 186-240 mm (7.3-9.47 in.) Ø100.6 mm (3.96 in.) Ø19.1 mm (0.75 in.) 55.8 mm (2.2 in.) 50.8 mm (2.0 in.)50.8 mm (2.0 in.) 76.2 mm (3.0 in.) 1/4-20 UNCE Female Mounting Threads Note: Detector Surface is 16 mm (0.63 in.) below front face of aperture plate Adjustable 168-220 mm (6.58-8.73 in.) Ø19.1 mm (0.75 in.) 35.8 mm (1.41 in.) Ø63 mm (2.48 in.) 50.8 mm (2.0 in.) 76.2 mm (3.0 in.) 50.8 mm (2.0 in.) 1/4-20 UNC Female Mounting Threads Note: Detector Surface is 10 mm (0.41 in.) below front face of aperture plate Adjustable 151-221 mm (5.95-8.7 in.) 46 mm (1.8 in.) 51 mm (2.0 in.) Ø19 mm (0.75 in.) 10 mm (0.4 in.) 51 mm (2.0 in.) 51 mm (2.0 in.) 76 mm (3.0 in.) 8-32 UNC Female Mounting Threads Note: Detector Surface is 5.5 mm (0.22 in.) below front face of aperture plate MECHANICAL SPECIFICATIONS PM2 PM30 PM10

Air-Cooled Thermopile Sensors to 150 W Datasheet SPECIFICATIONS PM100-19C 1 PM150 PM150-50 Wavelength Range (µm) 0.25 to 11 Power Range 300 mW to 100 W 300 mW to 150 W 300 mW to 150 W Long-Pulse Joules Range (J) 1 to 100 1 to 150 1 to 150 Maximum Intermittent Power (<5 min.) (W) 100 300 300 Resolution (mW) 30 Maximum Power Density (kW/cm 2) 6 Maximum Energy Density (mJ/cm 2) 600, 1064 nm, 10 ns Response Time (sec.) 2 2 5 Detector Coating Broadband Active Area Diameter (mm) 19 19 50 Calibration Uncertainty (%) (k=2) ±1 Calibration Wavelength (nm) 514 Cooling Method Air-cooled Cable Type PM DB-25 Cable Length (m) 2 Part Number 1098483 1098407 109839 1 This sensor is designed for intermittent use only. MECHANICAL SPECIFICATIONS PM100-19C PM150-50 PM150 1/4-20 UNC Female Mounting Threads 51 mm (2.0 in.) 51 mm (2.0 in.) 76 mm (3.0 in.) 89 mm (3.5 in.) 89 mm (3.5 in.) Ø19 mm (0.75 in.) 31 mm (1.23 in.) Note: Detector Surface is 7.2 mm (0.28 in.) below front face of aperture plate Adjustable 189-259 mm Female Mounting Threads Ø19 mm (0.75 in.) Ø151 mm (5.95 in.) Note: Detector Surface is 32.3 mm (1.27 in.) below front face of aperture plate 3/8-16 UNC Female Mounting Threads Ø50 mm (1.97 in.) Ø151 mm (5.95 in.) Note: Detector Surface is 32.2 mm (1.27 in.) below front face of aperture plate

Air-Cooled Thermopile Sensors to 150 W Datasheet SPECIFICATIONS PM2X PM10X PM30X Wavelength Range (µm) 0.15 to 1 Power Range 10 mW to 2 W 10 mW to 10 W 100 mW to 30 W Long-Pulse Joules Range (J) 0.5 to 2 0.5 to 10 0.5 to 50 Maximum Intermittent Power (<5 min.) (W) 5 30 50 Resolution (mW) 1 1 10 Maximum Power Density (kW/cm 2) 6 Maximum Energy Density (mJ/cm 2) 600, 1064 nm, 10 ns Response Time (sec.) 2 Detector Coating UV Active Area Diameter (mm) 19 Calibration Uncertainty (%) (k=2) ±1 Calibration Wavelength (nm) 514 Cooling Method Air-cooled Cable Type PM DB-25 Cable Length (m) 2 Part Number 1098457 1098423 10984981 1 C24 Quick Ship program: eligible for next business day shipment. MECHANICAL SPECIFICATIONS PM2X PM30X PM10X 8-32 UNC Female Mounting Threads 51 mm (2.0 in.) Ø19 mm (0.75 in.) 10 mm (0.4 in.) 46 mm (1.8 in.) 51 mm (2.0 in.) 51 mm (2.0 in.) Adjustable 151-221 mm (5.95-8.7 in.) 76 mm (3.0 in.) Note: Detector Surface is 5.5 mm (0.22 in.) below front face of aperture plate 1/4-20 UNC Female Mounting Threads 51 mm (2.0 in.) 51 mm (2.0 in.) 76 mm (3.0 in.) Ø19 mm (0.75 in.) 56 mm (2.2 in.) Ø101 mm (3.96 in.) Note: Detector Surface is 16.5 mm (0.65 in.) below front face of aperture plate Adjustable 201-271 mm (7.91-10.67 in.) 1/4-20 UNC Female Mounting Threads Adjustable 163-233 mm (6.42-9.17 in.) Ø19 mm (0.75 in.) 36 mm (1.41 in.) Ø63 mm (2.48 in.) 51 mm (2.0 in.) 51 mm (2.0 in.) 76 mm (3.0 in.) Note: Detector Surface is 10.9 mm (0.43 in.) below front face of aperture plate

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice. Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976. Coherent offers a limited warranty for all Thermopile Sensors. For full details of this warranty coverage, please refer to the Service section at www.coherent.com or contact your local Sales or Service Representative. MC-045-19-0M1119 Copyright ©2019 Coherent, Inc. Coherent, Inc.,

5100 Patrick Henry Drive Santa Clara, CA 95054

p. (800) 527-3786 | (408) 764-4983 f. (408) 764-4646 tech.sales@coherent.com www.coherent.com 3/8-16 UNC Female Mounting Threads Ø50 mm (1.97 in.) Ø151 mm (5.95 in.) Note: Detector Surface is 32.2 mm (1.27 in.) below front face of aperture plate Air-Cooled Thermopile Sensors to 150 W Datasheet SPECIFICATIONS PM150X Wavelength Range (µm) 0.15 to 1 Power Range 300 mW to 150 W Long-Pulse Joules Range (J) 1 to 150 Maximum Intermittent Power (<5 min.) (W) 300 Resolution (mW) 30 Maximum Power Density (kW/cm 2) 6 Maximum Energy Density (mJ/cm 2) 600, 1064 nm, 10 ns Response Time (sec.) 5 Detector Coating UV Active Area Diameter (mm) 50 Calibration Uncertainty (%) (k=2) ±1 Calibration Wavelength (nm) 514 Cooling Method Air-cooled Cable Type PM DB-25 Cable Length (m) 2 Part Number 1098455 MECHANICAL SPECIFICATIONS PM150X