IQC10-03BPPKQ8SA00 SICK | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 9
Technical content
INDUCTIVE PROXIMITY SENSORS
A B C D E F H I J K L M N O P Q R S T IQC10-03BPPKQ8SA00 | IMC INDUCTIVE PROXIMITY SENSORS Illustration may differ
Ordering information
Type Part no. IQC10-03BPPKQ8SA00 1083793 Other models and accessories www.sick.com/IMC Detailed technical data
Features
Dimensions (W x H x D) 10 mm x 28 mm x 16 mm Sensing range Sn 0 mm ... 3 mm 1) Safe sensing range Sa 2.43 mm Number of switching points Up to 4 adjustable switching points or windows Switching modes Single point, Window mode, Two point mode, Optical adjustment indicator Switching frequency Qint.1 / Qint.2 on Pin2 1,000 Hz Installation type Flush Connection type Cable with M12 male connector, 4-pin, 0.2 m 2) Switching output PNP Output Q/C Switching output or IO-Link mode Output MFC Switching output or input Output function NC / NO Output characteristic Programmable Electrical wiring DC 4-wire Enclosure rating IP68 3) Special features Smart Task Diagnosis Chip temperature Pin 2 configuration External input, Teach-in, switching signal 1) Adjustable. 2) With gold plated contact pins. 3) According to EN 60529.
2 PROXIMITY SENSORS | SICK Online data sheet | 2018-06-12 14:57:18
Subject to change without notice
IQC10-03BPPKQ8SA00 | IMC INDUCTIVE PROXIMITY SENSORS Communication interface Communication interface IO-Link V1.1 Mode COM2 (38,4 kBaud) Cycle time 5 ms Process data length 32 Bit Process data structure Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 = switching signal QInt3 Bit 3 = switching signal QInt4 Bit 16 ... 31 = distance value Factory setting Switching Point 1: reference value 1 Output: normally open Pin 2 configuration: input Mechanics/electronics Supply voltage 10 V DC ... 30 V DC 1) Ripple ≤ 10 % Voltage drop ≤ 2 V 2) Current consumption ≤ 35 mA 3) Hysteresis Programmable 4) Reproducibility ≤ 5 % 5) 6) Temperature drift (of Sr) ± 10 % EMC According to EN 60947-5-2 Continuous current Ia ≤ 200 mA 7) Short-circuit protection ✔ Reverse polarity protection ✔ Power-up pulse protection ✔ Shock and vibration resistance 30 g, 11 ms / 10 ... 55 Hz, 1 mm Ambient operating temperature –25 °C ... +75 °C Housing material Plastic, VISTAL® Sensing face material Plastic, VISTAL® Tightening torque, max. < 1 Nm Teach-in accuracy +/- 3% of Sr Resolution, typical (range) 20 μm (0 mm ... 3 mm) Resolution, maximum (area) 40 μm (0 mm ... 3 mm) 1) IO-Link mode: 18 VDC ... 30 VDC. 2) At Ia max. 3) Without load. 4) To comply with EN 60947-5-2, a hysteresis of approx. 10% must be set. 5) Ub and Ta constant. 6) Of Sr. 7) 200 mA total for both switching outputs. Reference values Note Reference value in Digits for switching point in mm stored in the sensor Reference value 1 3 mm 2018-06-12 14:57:18 | Online data sheet Subject to change without notice PROXIMITY SENSORS | SICK 3
A B C D E F H I J K L M N O P Q R S T IQC10-03BPPKQ8SA00 | IMC INDUCTIVE PROXIMITY SENSORS Reference value 2 2 mm Reference value 3 1 mm Reference value 4 0.5 mm Reduction factors Stainless steel (V2A, 304) Approx. 0.7 Aluminum (Al) Approx. 0.4 Copper (Cu) Approx. 0.3 Brass (Br) Approx. 0.5 Installation note Remark Associated graphic see "Installation" A 0 mm B 10 mm C 10.3 mm D 9 mm E 0 mm F 24 mm G 0 mm Classifications ECl@ss 5.0 27270101 ECl@ss 5.1.4 27270101 ECl@ss 6.0 27270101 ECl@ss 6.2 27270101 ECl@ss 7.0 27270101 ECl@ss 8.0 27270101 ECl@ss 8.1 27270101 ECl@ss 9.0 27270101 ETIM 5.0 EC002714 ETIM 6.0 EC002714 UNSPSC 16.0901 39122230 Smart Task Smart Task name Base logics Logic function AND OR XOR Hysteresis Timer function On delay Off delay ON and OFF delay Impulse (one shot) Inverter Adjustable 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/“deac- tivated”). 2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used. 3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
4 PROXIMITY SENSORS | SICK Online data sheet | 2018-06-12 14:57:18
Subject to change without notice
IQC10-03BPPKQ8SA00 | IMC INDUCTIVE PROXIMITY SENSORS Switching frequency SIO Direct: 1000 Hz 1) SIO Logic: 1000 Hz 2) IOL: 1000 Hz 3) Switching signal QL1 Switching output Switching signal QL2 Switching output 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/“deac- tivated”). 2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used. 3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters. Installation note G G E D B C A A F Connection diagram cd-367 1 + (L+) QL1 /C MF – (M) BN BK WH BU 2018-06-12 14:57:18 | Online data sheet Subject to change without notice PROXIMITY SENSORS | SICK 5
A B C D E F H I J K L M N O P Q R S T IQC10-03BPPKQ8SA00 | IMC INDUCTIVE PROXIMITY SENSORS Characteristic curve IQC10 (0.31) (0.16) (0.16) (0.31) 0 1 (0.04) (0.08) (0.12) (0.16) Sn in mm (inch) Distance in mm (inch) Dimensional drawing (Dimensions in mm (inch)) IQ10, cable 1 (0.04) Ø 3.7 (0.15) Ø 6 (0.24) 28 (1.1) 16 (0.63) Ø 3.2 (0.13) 5.7 (0.22) 2.9 (0.11) ① Connection ② LED indicator 270° Recommended accessories Other models and accessories www.sick.com/IMC Brief description Type Part no. Modules and gateways IO-Link V1.1 Class A port, USB2.0 port, optional external power supply 24V / 1A IOLA2US-01101 (SiLink2 Master) 1061790
6 PROXIMITY SENSORS | SICK Online data sheet | 2018-06-12 14:57:18
Subject to change without notice
IQC10-03BPPKQ8SA00 | IMC INDUCTIVE PROXIMITY SENSORS Brief description Type Part no. EtherCAT IO-Link Master, IO-Link V1.1, Port Class A, power supply via 7/8'' cable 24 V /
8 A, fieldbus connection via M12 cable
(IO-Link Master) 6053254 EtherNet/IP IO-Link Master, IO-Link V1.1, Port Class A, power supply via 7/8'' cable
24 V / 8 A, fieldbus connection via M12-cable
(IO-Link Master) 6053255 PROFINET IO-Link Master, IO-Link V1.1, Port Class A, power supply via 7/8'' cable 24 V / (IO-Link Master) 6053253 Plug connectors and cables Head A: female connector, M12, 4-pin, straight Head B: Flying leads Cable: PP, unshielded, 2 m This product is generally resistant to chemical cleaning agents (see ECOLAB) and other chemical compounds such as H2O2 and CH2O2. Before permanent installation is car- ried out, the material's resistance to the cleaning agent being used must be checked., Resistant against lactic acid & hydrogen peroxide (H2O2) DOL-1204-G02MRN 6058291 Head A: female connector, M12, 4-pin, straight Head B: Flying leads Cable: PP, unshielded, 5 m This product is generally resistant to chemical cleaning agents (see ECOLAB) and other chemical compounds such as H2O2 and CH2O2. Before permanent installation is car- ried out, the material's resistance to the cleaning agent being used must be checked., Resistant against lactic acid & hydrogen peroxide (H2O2) DOL-1204-G05MRN 6058476 Head A: female connector, M12, 4-pin, angled with LED Head B: Flying leads Cable: PP, unshielded, 2 m This product is generally resistant to chemical cleaning agents (see ECOLAB) and other chemical compounds such as H2O2 and CH2O2. Before permanent installation is car- ried out, the material's resistance to the cleaning agent being used must be checked., Resistant against lactic acid & hydrogen peroxide (H2O2) DOL-1204-L02MRN 6058482 Head A: female connector, M12, 4-pin, angled with LED Head B: Flying leads Cable: PP, unshielded, 5 m This product is generally resistant to chemical cleaning agents (see ECOLAB) and other chemical compounds such as H2O2 and CH2O2. Before permanent installation is car- ried out, the material's resistance to the cleaning agent being used must be checked., Resistant against lactic acid & hydrogen peroxide (H2O2) DOL-1204-L05MRN 6058483 Head A: female connector, M12, 4-pin, angled Head B: Flying leads Cable: PP, unshielded, 2 m This product is generally resistant to chemical cleaning agents (see ECOLAB) and other chemical compounds such as H2O2 and CH2O2. Before permanent installation is car- ried out, the material's resistance to the cleaning agent being used must be checked., Resistant against lactic acid & hydrogen peroxide (H2O2) DOL-1204-W02MRN 6058474 Head A: female connector, M12, 4-pin, angled Head B: Flying leads Cable: PP, unshielded, 5 m This product is generally resistant to chemical cleaning agents (see ECOLAB) and other chemical compounds such as H2O2 and CH2O2. Before permanent installation is car- ried out, the material's resistance to the cleaning agent being used must be checked., Resistant against lactic acid & hydrogen peroxide (H2O2) DOL-1204-W05MRN 6058477 Head A: female connector, M12, 4-pin, angled Head B: male connector, M12, 4-pin, straight Cable: PP, unshielded, 2 m This product is generally resistant to chemical cleaning agents (see ECOLAB) and other chemical compounds such as H2O2 and CH2O2. Before permanent installation is car- ried out, the material's resistance to the cleaning agent being used must be checked., Resistant against lactic acid & hydrogen peroxide (H2O2) DSL-1204-B02MRN 6058502 2018-06-12 14:57:18 | Online data sheet Subject to change without notice PROXIMITY SENSORS | SICK 7
A B C D E F H I J K L M N O P Q R S T IQC10-03BPPKQ8SA00 | IMC INDUCTIVE PROXIMITY SENSORS Brief description Type Part no. Head A: female connector, M12, 4-pin, angled Head B: male connector, M12, 4-pin, straight Cable: PP, unshielded, 5 m This product is generally resistant to chemical cleaning agents (see ECOLAB) and other chemical compounds such as H2O2 and CH2O2. Before permanent installation is car- ried out, the material's resistance to the cleaning agent being used must be checked., Resistant against lactic acid & hydrogen peroxide (H2O2) DSL-1204-B05MRN 6058503 Head A: female connector, M12, 4-pin, straight Head B: male connector, M12, 4-pin, straight Cable: PP, unshielded, 2 m This product is generally resistant to chemical cleaning agents (see ECOLAB) and other chemical compounds such as H2O2 and CH2O2. Before permanent installation is car- ried out, the material's resistance to the cleaning agent being used must be checked., Resistant against lactic acid & hydrogen peroxide (H2O2) DSL-1204-G02MRN 6058499 Head A: female connector, M12, 4-pin, straight Head B: male connector, M12, 4-pin, straight Cable: PP, unshielded, 5 m This product is generally resistant to chemical cleaning agents (see ECOLAB) and other chemical compounds such as H2O2 and CH2O2. Before permanent installation is car- ried out, the material's resistance to the cleaning agent being used must be checked., Resistant against lactic acid & hydrogen peroxide (H2O2) DSL-1204-G05MRN 6058500
8 PROXIMITY SENSORS | SICK Online data sheet | 2018-06-12 14:57:18
Subject to change without notice
SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com